{"id":226551,"date":"2024-10-19T14:43:34","date_gmt":"2024-10-19T14:43:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-tr-630372016\/"},"modified":"2024-10-25T08:40:54","modified_gmt":"2024-10-25T08:40:54","slug":"bsi-pd-iec-tr-630372016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-tr-630372016\/","title":{"rendered":"BSI PD IEC\/TR 63037:2016"},"content":{"rendered":"
This document specifies the electrical interface between phase-cut dimming equipment and lighting equipment, such as LED integrated lamps and light sources with external controlgear, with the intention of helping designers of both types of equipment to develop products that will work together properly.<\/p>\n
This document describes both the dimming phase and the off phase. In addition to the specification of the interface, test procedures are given for testing the proper operation.<\/p>\n
It may be expected that controlgear fulfilling the requirements of this document are also suited to be used with electronic switches that use a circuitry comparable with that of a phase-cut dimmer, but do not contain means for the adjustability of the phase-cut angle.<\/p>\n
Safety requirements are not covered by this document, but by respective product standards<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3.2 Abbreviated terms <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4 General description 5 General requirements 5.1 Voltage rating <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5.2 Frequency rating 5.3 Marking of controlgear 6 Description of the lighting system and its components 6.1 Wiring method 6.2 Wiring diagram Figures Figure 1 \u2013 Example of wiring diagram <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 7 Electrical specification 7.1 General 7.2 Electrical characteristics during the on state of a phase-cut dimming system <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Figure\u00a02 \u2013 Timing leading edge dimming method <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Tables Table 1 \u2013 Nominal mains voltage 100\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 2 \u2013 Nominal mains voltage 120\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 3 \u2013 Nominal mains voltage 200\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Table 4 \u2013 Nominal mains voltage 230\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 5 \u2013 Nominal mains voltage 277\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Table 6 \u2013 Slew rate for voltage decrease across the phase-cut dimmer Table 7 \u2013 Nominal mains voltage 100\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 8 \u2013 Nominal mains voltage 120\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Table 9 \u2013 Nominal mains voltage 200\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 10 \u2013 Nominal mains voltage 230\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 11 \u2013 Nominal mains voltage 277\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figure 3 \u2013 Timing trailing edge dimming method <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Table 12 \u2013 Nominal mains voltage from 100\u00a0V to 277\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 13 \u2013 Nominal mains voltage 100\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Table 14 \u2013 Nominal mains voltage 120\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 15 \u2013 Nominal mains voltage 200\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Table 16 \u2013 Nominal mains voltage 230\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz Table 17 \u2013 Nominal mains voltage 277\u00a0V; frequency 50\u00a0Hz or 60\u00a0Hz <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 7.3 Electrical characteristics during the off state of a phase-cut dimming system Table 18 \u2013 Currents and voltages for controlgear during the electronic off\u00a0state <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 8 Test procedures 8.1 General 8.2 Tests for leading edge dimmable devices Figure 4 \u2013 Test setup for testing the conducting phase Table 19 \u2013 Parameters for testing purposes <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 8.3 Tests for trailing edge dimmable devices <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Figure 5 \u2013 Test setup for the transition from the conducting to the non-conducting phase <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 8.4 Tests for characteristics during electronic off state Figure 6 \u2013 Test setup for the non-conducting phase <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex A (informative) Voltage shapes to be used with the tests in IEC TR 63037 A.1 General A.2 Waveform description A.3 Waveform description Figure A.1 \u2013 Waveform of AC voltage source Figure A.2 \u2013 Waveform of AC voltage source <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex B (informative) Equivalent phase-cut dimmer circuit Figure B.1 \u2013 Scheme of the EC_D <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Electrical interface specifications for self ballasted lamps and controlgear in phase-cut dimmed lighting systems<\/b><\/p>\n |