{"id":82525,"date":"2024-10-18T03:06:12","date_gmt":"2024-10-18T03:06:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-519-1981\/"},"modified":"2024-10-24T19:50:30","modified_gmt":"2024-10-24T19:50:30","slug":"ieee-519-1981","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-519-1981\/","title":{"rendered":"IEEE 519 1981"},"content":{"rendered":"

New IEEE Standard – Inactive – Superseded. This guide applies to all types of static power converters used in industrial and commercial power systems. The problems involved in the harmonic control and reactive compensation of such converters are addressed, and an application guide is provided. Limits of disturbances to the AC power distribution system that affect other equipment and communications are recommended. This guide is not intended to cover the effect of radio frequency interference.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
9<\/td>\n1 IntroductionandScope
1.1 Introduction
1.2 Scope
2 Definitions and Letter Symbols
2.1 Definitions <\/td>\n<\/tr>\n
11<\/td>\n2.2 Letter Symbols <\/td>\n<\/tr>\n
13<\/td>\n3 References
3.1 Standards References
3.2 References
4 Converter Theory and Harmonic Generation
4.1 Introduction <\/td>\n<\/tr>\n
14<\/td>\nCurrent and Voltage Wave Forms Delta Six.Phase Y Double Way <\/td>\n<\/tr>\n
16<\/td>\nRelations Among Angles Used in Converter Theory <\/td>\n<\/tr>\n
17<\/td>\n5 Reactive Power Compensation and Harmonic Control Techniques
5.1 Converter Power Factor
Theoretical and Typical Values of Harmonic Current For a Six-Pulse Converter
Relationship Between Distortion Displacement and Total Power Component <\/td>\n<\/tr>\n
18<\/td>\nTotal Power Factor of Six-Pulse and Twelve-Pulse Converters a =
(Neglecting Transformer Exciting Current) <\/td>\n<\/tr>\n
19<\/td>\n5.2 Reactive Power Compensation
Reactive Power Versus dc Volts of Converter
Effect of Reactive Power <\/td>\n<\/tr>\n
20<\/td>\nCapacitors Switched in Binary Values
Static VAR Control <\/td>\n<\/tr>\n
21<\/td>\nThree-phase Diagram of One Bank of Capacitors
Fig 12 Self Saturating Reactor Scheme <\/td>\n<\/tr>\n
22<\/td>\nPower System Showing Harmonic Current and Voltage Influences <\/td>\n<\/tr>\n
23<\/td>\nProblems and Control of Harmonics <\/td>\n<\/tr>\n
24<\/td>\n6 Calculation Methods
Calculation of Harmonic Currents
6.2 System Analysis
Static Power Converter in Per-Unit of the Fundamental Current <\/td>\n<\/tr>\n
25<\/td>\nImpedance Diagram of Power System <\/td>\n<\/tr>\n
26<\/td>\n6.3 Telephone Interference
Line Notching Calculations (For Low Voltage Systems)
Fig 15 Three-phase Full Wave Converter <\/td>\n<\/tr>\n
27<\/td>\nVoltage Notches
Fig17 InductanceDiagram <\/td>\n<\/tr>\n
28<\/td>\n6.5 Distortion Factor
System Calculation (Low Voltage Below <\/td>\n<\/tr>\n
29<\/td>\n6.7 Power Factor Improvement Calculation
Typical Power System and Equivalent Diagram <\/td>\n<\/tr>\n
30<\/td>\n7 Measurements
Power-Reactive Triangle for Power Factor Correction <\/td>\n<\/tr>\n
31<\/td>\n7.1 LineNotching
Using Potential Transformer and Current Transformer <\/td>\n<\/tr>\n
32<\/td>\n7.2 Harmonics
7.3 Telephone Interference <\/td>\n<\/tr>\n
33<\/td>\n7.4 Flicker
Power Factor Correction
8 Recommended Practices
8.1 LineNotching <\/td>\n<\/tr>\n
34<\/td>\nNotch Depth Reduction
Simplified Diagram Power Distribution System <\/td>\n<\/tr>\n
35<\/td>\nConverter Connection to Distribution System <\/td>\n<\/tr>\n
36<\/td>\nPower Factor Correction
8.3 Harmonics
and Shunt Capacitance Reactances
Low Voltage System Classification and Distortion Limits for 460 V Systems <\/td>\n<\/tr>\n
37<\/td>\nFig 25 Power System with Shunt Filters
Fig26 Shuntpower Filter <\/td>\n<\/tr>\n
38<\/td>\n8.4 Telephone Interference
Typical Filter Configuration Versus System Size
Voltage Distortion Limits for Medium and High Voltage Power Systems <\/td>\n<\/tr>\n
40<\/td>\nfor Six- and Twelve-Pulse Rectifiers
1960 Single Frequency TIF Values <\/td>\n<\/tr>\n
41<\/td>\n1960 TIF Weighting Values
Typical 1.T Values for 48 V dc Converters
Typical 1.T Values for 48 V dc Ferroresonant Converters <\/td>\n<\/tr>\n
42<\/td>\n8.5 Flicker
Balanced I*T Guidelines for Converter Installations Tie (Supply) Lines <\/td>\n<\/tr>\n
43<\/td>\nMaximum Permissible Voltage Fluctuations <\/td>\n<\/tr>\n
44<\/td>\n9 Bibliography
Books and General Discussion <\/td>\n<\/tr>\n
45<\/td>\nReal and Wattless Power <\/td>\n<\/tr>\n
46<\/td>\nWaveform Analysis and Measurement Techniques
9.4 Standards and Engineering Recommendations <\/td>\n<\/tr>\n
47<\/td>\nWaveform Analysis and Means for Harmonic Suppression\/Power Averaging <\/td>\n<\/tr>\n
50<\/td>\nEffects on Components and Systems <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Guide for Harmonic Control and Reactive Compensation of Static Power Convertors<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n1981<\/td>\n54<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":82526,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-82525","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/82525","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/82526"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=82525"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=82525"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=82525"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}