{"id":81334,"date":"2024-10-17T18:53:40","date_gmt":"2024-10-17T18:53:40","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-802-1ag-2007\/"},"modified":"2024-10-24T19:46:25","modified_gmt":"2024-10-24T19:46:25","slug":"ieee-802-1ag-2007","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-802-1ag-2007\/","title":{"rendered":"IEEE 802.1ag 2007"},"content":{"rendered":"

Amendment Standard – Inactive – Superseded. This amendment specifies protocols, procedures, and managed objects to support connectivity fault management. These allow discovery and verification of the path, through bridges and LANs, taken for frames addressed to and from specified network users. Connectivity faults can be detected and isolated to an individual bridge or LAN.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
3<\/td>\nIEEE Standard for Local and Metropolitan Area Networks\u2014Virtual Bridged Local Area Networks\u2014Amendment 5: Connectivity Fault Management <\/td>\n<\/tr>\n
4<\/td>\nAbstract\/Keywords <\/td>\n<\/tr>\n
6<\/td>\nIntroduction <\/td>\n<\/tr>\n
7<\/td>\nNotice to users <\/td>\n<\/tr>\n
8<\/td>\nParticipants <\/td>\n<\/tr>\n
12<\/td>\nContents <\/td>\n<\/tr>\n
15<\/td>\n1. Overview
1.1 Scope <\/td>\n<\/tr>\n
17<\/td>\n2. Normative references <\/td>\n<\/tr>\n
19<\/td>\n3. Definitions <\/td>\n<\/tr>\n
23<\/td>\n4. Abbreviations <\/td>\n<\/tr>\n
25<\/td>\n5. Conformance
5.10 VLAN-aware end station requirements for Connectivity Fault Management <\/td>\n<\/tr>\n
27<\/td>\n6. Support of the MAC Service in VLANs
6.1 Basic architectural concepts and terms <\/td>\n<\/tr>\n
30<\/td>\n6.2 Provision of the MAC service <\/td>\n<\/tr>\n
31<\/td>\n6.3 Support of the MAC service <\/td>\n<\/tr>\n
32<\/td>\n6.15 EISS Multiplex Entity <\/td>\n<\/tr>\n
35<\/td>\n8. Principles of bridge operation
8.3 Model of operation
8.12 Bridge management entity
8.13 Addressing <\/td>\n<\/tr>\n
37<\/td>\n12. Bridge management
12.1 Management functions
12.2 Managed objects
12.14 CFM entities <\/td>\n<\/tr>\n
55<\/td>\n15. Support of the MAC Service by Provider Bridged Networks
15.10 Connectivity Fault Management <\/td>\n<\/tr>\n
57<\/td>\n17. Management protocol
17.1 Internet Standard Management Framework
17.2 Relationship with the managed objects definitions <\/td>\n<\/tr>\n
62<\/td>\n17.3 Relationship to other MIB modules
17.4 Security <\/td>\n<\/tr>\n
64<\/td>\n17.5 Definitions for the Connectivity Fault Management MIB <\/td>\n<\/tr>\n
131<\/td>\n18. Principles of Connectivity Fault Management operation <\/td>\n<\/tr>\n
132<\/td>\n18.1 Maintenance Domains and Domain Service Access Points <\/td>\n<\/tr>\n
133<\/td>\n18.2 Service instances and Maintenance Associations <\/td>\n<\/tr>\n
135<\/td>\n18.3 Maintenance Domain Levels <\/td>\n<\/tr>\n
139<\/td>\n19. Connectivity Fault Management Entity operation
19.1 Maintenance Points <\/td>\n<\/tr>\n
140<\/td>\n19.2 Maintenance association End Point <\/td>\n<\/tr>\n
145<\/td>\n19.3 MIP Half Function <\/td>\n<\/tr>\n
148<\/td>\n19.4 Maintenance Point addressing <\/td>\n<\/tr>\n
149<\/td>\n19.5 Linktrace Output Multiplexer <\/td>\n<\/tr>\n
150<\/td>\n19.6 Linktrace Responder <\/td>\n<\/tr>\n
151<\/td>\n20. Connectivity Fault Management protocols <\/td>\n<\/tr>\n
152<\/td>\n20.1 Continuity Check protocol <\/td>\n<\/tr>\n
155<\/td>\n20.2 Loopback protocol <\/td>\n<\/tr>\n
156<\/td>\n20.3 Linktrace protocol <\/td>\n<\/tr>\n
160<\/td>\n20.4 Connectivity Fault Management state machines
20.5 CFM state machine timers <\/td>\n<\/tr>\n
162<\/td>\n20.6 CFM procedures
20.7 Maintenance Domain variable
20.8 Maintenance Association variables
20.9 MEP variables <\/td>\n<\/tr>\n
164<\/td>\n20.10 MEP Continuity Check Initiator variables <\/td>\n<\/tr>\n
165<\/td>\n20.11 MEP Continuity Check Initiator procedures
20.12 MEP Continuity Check Initiator state machine
20.13 MHF Continuity Check Receiver variables <\/td>\n<\/tr>\n
166<\/td>\n20.14 MHF Continuity Check Receiver procedures
20.15 MHF Continuity Check Receiver state machine <\/td>\n<\/tr>\n
167<\/td>\n20.16 MEP Continuity Check Receiver variables <\/td>\n<\/tr>\n
169<\/td>\n20.17 MEP Continuity Check Receiver procedures <\/td>\n<\/tr>\n
170<\/td>\n20.18 MEP Continuity Check Receiver state machine
20.19 Remote MEP variables <\/td>\n<\/tr>\n
172<\/td>\n20.20 Remote MEP state machine
20.21 Remote MEP Error variables <\/td>\n<\/tr>\n
173<\/td>\n20.22 Remote MEP Error state machine
20.23 MEP Cross Connect variables <\/td>\n<\/tr>\n
174<\/td>\n20.24 MEP Cross Connect state machine
20.25 MP Loopback Responder variables <\/td>\n<\/tr>\n
175<\/td>\n20.26 MP Loopback Responder procedures
20.27 MP Loopback Responder state machine <\/td>\n<\/tr>\n
176<\/td>\n20.28 MEP Loopback Initiator variables <\/td>\n<\/tr>\n
177<\/td>\n20.29 MEP Loopback Initiator transmit procedures
20.30 MEP Loopback Initiator transmit state machine <\/td>\n<\/tr>\n
178<\/td>\n20.31 MEP Loopback Initiator receive procedures <\/td>\n<\/tr>\n
179<\/td>\n20.32 MEP Loopback Initiator receive state machine
20.33 MEP Fault Notification Generator variables <\/td>\n<\/tr>\n
181<\/td>\n20.34 MEP Fault Notification Generator procedures
20.35 MEP Fault Notification Generator state machine <\/td>\n<\/tr>\n
182<\/td>\n20.36 MEP Linktrace Initiator variables <\/td>\n<\/tr>\n
184<\/td>\n20.37 MEP Linktrace Initiator procedures
20.38 MEP Linktrace Initiator receive variables <\/td>\n<\/tr>\n
185<\/td>\n20.39 MEP Linktrace Initiator receive procedures
20.40 MEP Linktrace Initiator receive state machine
20.41 Linktrace Responder variables <\/td>\n<\/tr>\n
186<\/td>\n20.42 LTM Receiver procedures <\/td>\n<\/tr>\n
192<\/td>\n20.43 LTM Receiver state machine
20.44 LTR Transmitter procedure <\/td>\n<\/tr>\n
193<\/td>\n20.45 LTR Transmitter state machine
20.46 CFM PDU validation and versioning <\/td>\n<\/tr>\n
196<\/td>\n20.47 PDU identification <\/td>\n<\/tr>\n
197<\/td>\n20.48 Use of transaction IDs and sequence numbers <\/td>\n<\/tr>\n
199<\/td>\n21. Encoding of CFM Protocol Data Units
21.1 Structure, representation, and encoding
21.2 CFM encapsulation <\/td>\n<\/tr>\n
200<\/td>\n21.3 CFM request and indication parameters
21.4 Common CFM Header <\/td>\n<\/tr>\n
202<\/td>\n21.5 TLV Format <\/td>\n<\/tr>\n
207<\/td>\n21.6 Continuity Check Message format <\/td>\n<\/tr>\n
212<\/td>\n21.7 Loopback Message and Loopback Reply formats <\/td>\n<\/tr>\n
213<\/td>\n21.8 Linktrace Message Format <\/td>\n<\/tr>\n
215<\/td>\n21.9 Linktrace Reply Format <\/td>\n<\/tr>\n
221<\/td>\n22. Connectivity Fault Management in systems
22.1 CFM shims in Bridges <\/td>\n<\/tr>\n
231<\/td>\n22.2 Maintenance Entity creation <\/td>\n<\/tr>\n
235<\/td>\n22.3 MPs, Ports, and MD Level assignment <\/td>\n<\/tr>\n
236<\/td>\n22.4 Stations and Connectivity Fault Management
22.5 Scalability of Connectivity Fault Management <\/td>\n<\/tr>\n
238<\/td>\n22.6 CFM in Provider Bridges <\/td>\n<\/tr>\n
240<\/td>\n22.7 Management Port MEPs and CFM in the enterprise environment <\/td>\n<\/tr>\n
242<\/td>\n22.8 Implementing CFM on existing Bridges <\/td>\n<\/tr>\n
243<\/td>\nAnnex A (normative) PICS proforma <\/td>\n<\/tr>\n
251<\/td>\nAnnex H (informative) Bibliography <\/td>\n<\/tr>\n
253<\/td>\nAnnex J (informative) Connectivity Fault Management protocol design and use <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Standard for Local and Metropolitan Area Networks Virtual Bridged Local Area Networks Amendment 5: Connectivity Fault Management<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2007<\/td>\n260<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":81335,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-81334","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/81334","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/81335"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=81334"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=81334"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=81334"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}