{"id":80679,"date":"2024-10-17T18:46:54","date_gmt":"2024-10-17T18:46:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-100-1999\/"},"modified":"2024-10-24T19:44:20","modified_gmt":"2024-10-24T19:44:20","slug":"ieee-c57-100-1999","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-100-1999\/","title":{"rendered":"IEEE C57.100 1999"},"content":{"rendered":"
Revision Standard – Inactive – Superseded. A test procedure is established to provide a uniform method for investigating the effect of operating temperature on the life expectancy of liquid-immersed transformers. The test proce-dures are intended to provide data for the selection of a limiting hottest-spot temperature for rating purposes, provide data which may serve as the basis for a guide for loading, and permit the com-parative evaluation of a proposed insulation system with reference to a system that has proven to be acceptable in service.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 2. References <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 3. Aging influences 4. Minimum life expectancy 5. Criteria for end of life <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 6. Test temperatures 7. Test specimens and procedures 7.1 Distribution transformers 7.2 Power transformers <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 8. Test period 8.1 Hottest-spot test temperature 8.2 Temperature of liquid 8.3 Duration of test period <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 8.4 Cycling 8.5 Calculation of aging caused by heating and cooling 9. End-point tests 9.1 Distribution transformers <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 9.2 Power transformers 9.3 Abnormalities 10. Test results <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 11. Applicability of test results 12. Other tests <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Annex A\u2014Standard test procedure for sealed tube aging of liquid- immersed transformer insulation <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Annex B\u2014Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard Test Procedure for Thermal Evaluation of Liquid-Immersed Distribution and Power Transformers<\/b><\/p>\n |