{"id":71140,"date":"2024-10-17T15:29:48","date_gmt":"2024-10-17T15:29:48","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-1906-12\/"},"modified":"2024-10-24T18:54:55","modified_gmt":"2024-10-24T18:54:55","slug":"nfpa-1906-12","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-1906-12\/","title":{"rendered":"NFPA 1906 12"},"content":{"rendered":"

NFPA 1906 helps you ensure wildland fire apparatus are up to the task. NFPA 1906: Standard for Wildland Fire Apparatus defines the requirements for a new automotive wildland fire apparatus, including apparatus equipped with a slip-on fire fighting module, designed primarily to support wildland fire suppression operations. This edition has been updated, rewritten, and reorganized to be similar to the 2009 edition of NFPA 1901: Standard for Automotive Fire Apparatus. Designed for easy reference, The 2012 NFPA 1906 includes:     A new section on Wildland Mobile Water Supply Fire Apparatus     Separate chapters addressing chassis and vehicle components; low voltage electrical systems and warning devices; driving and crew areas; body, compartments, and equipment mounting; pumps for wildland fire fighting and associated equipment; and water tanks NFPA 1906 is essential for manufacturers and professionals responsible for apparatus purchasing or evaluation.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nImportant Notices and Disclaimers <\/td>\n<\/tr>\n
3<\/td>\nAdditional Notices and Disclaimers <\/td>\n<\/tr>\n
4<\/td>\n2.1 General
2.2 NFPA Publications <\/td>\n<\/tr>\n
8<\/td>\nChapter 1 Administration
1.1 Scope
1.2 Purpose
1.3 Application
1.4 Retroactivity
1.5 Equivalency
1.6 Units of Measure
Chapter 2 Referenced Publications
2.3 Other Publications <\/td>\n<\/tr>\n
9<\/td>\n2.4 References for Extracts in Mandatory Sections
Chapter 3 Definitions
3.1 General <\/td>\n<\/tr>\n
10<\/td>\n3.2 NFPA Official Definitions
3.3 General Definitions <\/td>\n<\/tr>\n
14<\/td>\nChapter 4 General Requirements
4.1 General
4.2 Requirements by Apparatus Type
4.3 Reserved
4.4 Reserved
4.5 Fire Apparatus Components
4.6 Legal Requirements
4.7 Third-Party Certification of Test Results
4.8 Manufacturer Certification of Test Results
4.9 Personnel Protection <\/td>\n<\/tr>\n
15<\/td>\n4.10 Controls and Instructions
4.11 Reserved
4.12 Component Protection
4.13 Vehicle Stability <\/td>\n<\/tr>\n
16<\/td>\n4.14 Fire Apparatus Performance
4.15 Roadability
4.16 Serviceability
4.17 Road Tests
4.18 Tests on Delivery
4.19 Documentation
4.20 Data Required of the Contractor <\/td>\n<\/tr>\n
18<\/td>\n4.21 Statement of Exceptions
Chapter 5 Wildland Fire Apparatus
5.1 General
5.2 Pump
5.3 Reserved
5.4 Water Tank
5.5 Equipment Storage
5.6 Hose Storage
5.7 Equipment. <\/td>\n<\/tr>\n
19<\/td>\nChapter 6 Reserved
Chapter 7 Wildland Mobile Water Supply Fire Apparatus
7.1 General
7.2 Pump
7.3 Reserved
7.4 Water Tank
7.5 Equipment Storage
7.6 Hose Storage
7.7 Equipment
Chapter 8 Reserved
Chapter 9 Reserved
Chapter 10 Reserved
Chapter 11 Reserved
Chapter 12 Chassis and Vehicle Components
12.1 Carrying Capacity <\/td>\n<\/tr>\n
20<\/td>\n12.2 Engine and Engine System Design <\/td>\n<\/tr>\n
22<\/td>\n12.3 Vehicle Components <\/td>\n<\/tr>\n
23<\/td>\nChapter 13 Low-Voltage Electrical Systems and Warning Devices
13.1 General
13.2 Wiring
13.3 Power Supply <\/td>\n<\/tr>\n
24<\/td>\n13.4 Batteries
13.5 Starting Device
13.6 Temperature Exposure
13.7 Electromagnetic Interference <\/td>\n<\/tr>\n
25<\/td>\n13.8 Optical Warning Devices. <\/td>\n<\/tr>\n
28<\/td>\n13.9 Audible Warning Devices
13.10 Work Lighting
13.11 Reserved
13.12 Backup Alarm
13.13 Stop, Tail, and Directional Lights <\/td>\n<\/tr>\n
29<\/td>\n13.14 Electrical System Performance Tests
13.15 Documentation
Chapter 14 Driving and Crew Areas
14.1 General <\/td>\n<\/tr>\n
31<\/td>\n14.2 Cab Tilt Systems
14.3 Driving Compartment <\/td>\n<\/tr>\n
32<\/td>\nChapter 15 Body, Compartments, and Equipment Mounting
15.1 Compartmentation
15.2 Reserved
15.3 Equipment Containment
15.4 Powered Equipment Racks
15.5 SCBA Storage <\/td>\n<\/tr>\n
33<\/td>\n15.6 Pump and Plumbing Access
15.7 Stepping, Standing, and Walking Surfaces
15.8 Access Handrails or Handholds <\/td>\n<\/tr>\n
34<\/td>\n15.9 Metal Finish
15.10 Hose Storage
15.11 Requirements for Mounting of Ground Ladders
15.12 Receivers and Anchors for Rope and Removable Winches <\/td>\n<\/tr>\n
35<\/td>\n15.13 Slip-On Fire-Fighting Module.
Chapter 16 Pumps for Wildland Fire Fighting and Associated Equipment
16.1 Application
16.2 Design and Performance Requirements <\/td>\n<\/tr>\n
36<\/td>\n16.3 Pump Engine Requirements <\/td>\n<\/tr>\n
38<\/td>\n16.4 Power Train Capability
16.5 Construction Requirements
16.6 Pump Intake. <\/td>\n<\/tr>\n
39<\/td>\n16.7 Pump Discharge Outlets <\/td>\n<\/tr>\n
40<\/td>\n16.8 Pump Drains
16.9 Pump Operator’s Location
16.10 Pump Controls <\/td>\n<\/tr>\n
42<\/td>\n16.11 Pump Engine Controls <\/td>\n<\/tr>\n
43<\/td>\n16.12 Instrumentation <\/td>\n<\/tr>\n
44<\/td>\n16.13 Required Testing <\/td>\n<\/tr>\n
47<\/td>\nChapter 17 Reserved
Chapter 18 Water Tanks
18.1 General
18.2 Tank Construction <\/td>\n<\/tr>\n
48<\/td>\n18.3 Tank-to-Pump Intake Line
18.4 Filling and Venting
18.5 Reserved
18.6 Water Tank Capacity Certification
Chapter 19 Reserved
Chapter 20 Foam Proportioning Systems for Class A Foam Concentrate
20.1 Application. <\/td>\n<\/tr>\n
49<\/td>\n20.2 Requirements by Type of Foam Proportioning System
20.3 Design and Performance Requirements of a Foam Proportioning System
20.4 Controls for Foam Proportioning Systems
20.5 Foam Proportioning System Pressure Gauges, Flowmeters, and Indicators <\/td>\n<\/tr>\n
50<\/td>\n20.6 Atmospheric Foam Concentrate Tank
20.7 Foam Concentrate Pump <\/td>\n<\/tr>\n
51<\/td>\n20.8 Pressure Vessel Foam Concentrate or Foam Solution Tanks
20.9 Labels and Instruction Plates.
20.10 Foam Proportioning System Accuracy <\/td>\n<\/tr>\n
52<\/td>\n20.11 Testing and Documentation
Chapter 21 Compressed Air Foam Systems (CAFS)
21.1 Application
21.2 General Requirements
21.3 Compressed Air System <\/td>\n<\/tr>\n
53<\/td>\n21.4 Air Mixing
21.5 Compressed Air System Piping
21.6 Air System Controls
21.7 Foam System Pressure Gauges, Flowmeters, and Indicators
21.8 Labels and Instruction Plates
21.9 Manufacturer’s Predelivery Tests. <\/td>\n<\/tr>\n
54<\/td>\nChapter 22 Reserved
Chapter 23 Reserved
Chapter 24 Reserved
Chapter 25 Winches
25.1 General
25.2 Winch Wire or Synthetic Rope
25.3 Clutch <\/td>\n<\/tr>\n
55<\/td>\n25.4 Electric Powered Winches
25.5 Hydraulically Driven Winches
Chapter 26 Reserved
Chapter 27 Vehicle Protection Systems
27.1 Brush Rails <\/td>\n<\/tr>\n
56<\/td>\n27.2 Grille Guard
27.3 Skid Plates
Annex A Explanatory Material <\/td>\n<\/tr>\n
82<\/td>\nAnnex B Specifying and Procuring Wildland Fire Apparatus <\/td>\n<\/tr>\n
104<\/td>\nAnnex C Weights and Dimensions for Common Equipment <\/td>\n<\/tr>\n
113<\/td>\nAnnex D Guidelines for First Line and Reserve Apparatus <\/td>\n<\/tr>\n
115<\/td>\nAnnex E Methods for Testing a Foam Proportioning System for Calibration <\/td>\n<\/tr>\n
116<\/td>\nAnnex F Informational References <\/td>\n<\/tr>\n
118<\/td>\nIndex <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

NFPA 1906: Standard for Wildland Fire Apparatus<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NFPA<\/b><\/a><\/td>\n2012<\/td>\n125<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":71141,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-71140","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/71140","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/71141"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=71140"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=71140"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=71140"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}