{"id":59202,"date":"2024-10-17T11:01:12","date_gmt":"2024-10-17T11:01:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e2373-2004\/"},"modified":"2024-10-24T17:38:23","modified_gmt":"2024-10-24T17:38:23","slug":"astm-e2373-2004","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e2373-2004\/","title":{"rendered":"ASTM-E2373 2004"},"content":{"rendered":"<\/p>\n
1.1 This practice establishes the requirements for developing ultrasonic examination procedures using the ultrasonic technique known as Time-of-Flight Diffraction (TOFD).<\/p>\n
1.2 The values stated in SI units are to be regarded as standard. Inch-pound units are provided for information.<\/p>\n
1.3 Consistent with ASTM Policy, TOFD may be regarded as an ultrasonic test method whereby the qualities and characteristics of the item tested are evaluated, measured and in some cases identified. Measurements may be subject to precision and bias that may be determined statistically or as a function of some parameter(s) such as wavelength. This practice may be used for applications that would be qualitative and properly addressed as examinations as well as quantitative and more properly addressed as tests.<\/p>\n
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Terminology Significance and Use <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Procedures FIG. 1 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | FIG. 2 FIG. 3 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | FIG. 4 <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | TABLE 1 TABLE 2 TABLE 3 <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FIG. 5 <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | TOFD Analysis FIG. 6 FIG. 7 <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Reporting and Acceptance Criteria Keywords X1. SAMPLE REFERENCE SENSITIVITY BLOCKS X1.1 For Steel Thickness Ranges up to 75 mm [3 in.] FIG. X1.1 <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | X1.2 For Steel Thickness Ranges from 75 mm [3 in.] to 300 mm [12 in.] X1.3 Other Targets and Block Configurations FIG. X1.2 <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | FIG. X1.3 FIG. X1.4 FIG. X1.5 <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | X2. CURVED PLATE X2.1 X2.2 Scanning from a Concave Surface X2.3 Scanning from a Convex Surface FIG. X2.1 FIG. X2.2 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" E2373-04 Standard Practice for Use of the Ultrasonic Time of Flight Diffraction (TOFD) Technique<\/b><\/p>\n |