{"id":460332,"date":"2024-10-20T10:09:10","date_gmt":"2024-10-20T10:09:10","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-24-30489413-dc\/"},"modified":"2024-10-26T18:46:07","modified_gmt":"2024-10-26T18:46:07","slug":"bsi-24-30489413-dc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-24-30489413-dc\/","title":{"rendered":"BSI 24\/30489413 DC"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n30489413-NC.pdf <\/td>\n<\/tr>\n
3<\/td>\n100_4132e_CDV.pdf <\/td>\n<\/tr>\n
6<\/td>\nContents <\/td>\n<\/tr>\n
9<\/td>\nList of Tables <\/td>\n<\/tr>\n
11<\/td>\n1 Introduction
1.1 Overview <\/td>\n<\/tr>\n
13<\/td>\n2 Magnetic Power Profile
2.1 Overview
2.1.1 Restricted Mode
2.1.2 Full Mode <\/td>\n<\/tr>\n
14<\/td>\n2.2 Power Receiver Requirements
2.2.1 Amplitude Shift Keying (ASK)
2.2.2 Startup Behavior
Signal Strength (SIG) <\/td>\n<\/tr>\n
15<\/td>\nIdentification (ID)
Field Value
Extended Identification (XID) <\/td>\n<\/tr>\n
16<\/td>\nPower Control Hold-Off (PCH) – Optional
Configuration (CFG)
2.2.3 Profile Activation <\/td>\n<\/tr>\n
18<\/td>\n2.3 Power Transmitter Requirements
2.3.1 Frequency Shift Keying (FSK)
Packet Format
FSK Pattern <\/td>\n<\/tr>\n
19<\/td>\n2.3.2 Timings Override
FSK Response Window
No Power Signal Window
2.3.3 Startup Behavior <\/td>\n<\/tr>\n
20<\/td>\nMPP Restricted Mode
MPP Full Mode <\/td>\n<\/tr>\n
22<\/td>\n2.4 Supporting EPP and MPP protocols
2.4.1 MPP\/EPP Support on PRx <\/td>\n<\/tr>\n
23<\/td>\n2.4.2 MPP\/EPP Support on PTx <\/td>\n<\/tr>\n
24<\/td>\n3 Negotiation Phase
3.1 Overview
Note on EPP compatibility
3.2 Requirements <\/td>\n<\/tr>\n
25<\/td>\n3.2.1 Negotiation Phase Timings
3.2.2 FSK Cycles
3.2.3 Entering Negotiation Phase With Error Status <\/td>\n<\/tr>\n
26<\/td>\n3.2.4 Power Transfer Contract Extension <\/td>\n<\/tr>\n
27<\/td>\n3.3 Negotiation Phase – 128kHz
3.3.1 Nominal negotiation flow <\/td>\n<\/tr>\n
29<\/td>\n3.3.2 Negotiation flow with PTx error status <\/td>\n<\/tr>\n
30<\/td>\n3.3.3 Frequency Selection
3.4 Negotiation Phase – 360kHz <\/td>\n<\/tr>\n
33<\/td>\n3.4.1 PRx Extended Capabilities
3.4.2 PTx Extended Capabilities
3.4.3 Exchange Power Loss Accounting Parameters
3.4.4 Power Negotiation
3.4.5 Retrieve PTx Extended ID
3.4.6 Exchange Enabled Data Streams
3.4.7 Power Control Profile
3.4.8 Cloaking Duration <\/td>\n<\/tr>\n
34<\/td>\n3.4.9 MPP Proprietary Requests \/ Packets <\/td>\n<\/tr>\n
35<\/td>\n3.5 NFC Identification (Informative) <\/td>\n<\/tr>\n
36<\/td>\n4 Power Transfer Phase
4.1 Overview
4.2 Extended Control Error Packet
4.2.1 Handling <\/td>\n<\/tr>\n
37<\/td>\n4.2.2 PTx Response
4.2.3 Example <\/td>\n<\/tr>\n
39<\/td>\n4.3 Power Loss Accounting Packet
4.3.1 Handling <\/td>\n<\/tr>\n
40<\/td>\n4.3.2 PTx Response
4.4 Control Status
4.5 GET Request
4.5.1 PRx Initiated <\/td>\n<\/tr>\n
41<\/td>\n4.5.2 PTx Initiated
4.5.3 Examples <\/td>\n<\/tr>\n
42<\/td>\n4.6 MPP-Restricted to Full mode Transition <\/td>\n<\/tr>\n
43<\/td>\n4.6.1 Transition with power interruption
4.6.2 Transition without power interruption <\/td>\n<\/tr>\n
46<\/td>\n5 Cloak Phase
5.1 Overview
5.2 Cloak Ping Requirements
5.3 Cloak Entry <\/td>\n<\/tr>\n
47<\/td>\n5.3.1 PRx Initiated
5.3.2 PTx Initiated <\/td>\n<\/tr>\n
48<\/td>\n5.4 Cloak Exit <\/td>\n<\/tr>\n
49<\/td>\n5.5 Detect ping
5.6 State Diagram <\/td>\n<\/tr>\n
52<\/td>\n5.7 Cloak Timings
Parameter Side Symbol Minimum Target Maximum Unit <\/td>\n<\/tr>\n
53<\/td>\n5.8 Examples <\/td>\n<\/tr>\n
59<\/td>\n6 Extended Data Streams
6.1 Overview
6.2 Simultaneous Data Stream Extension <\/td>\n<\/tr>\n
60<\/td>\n6.2.1 Error Handling
6.2.2 Timings
6.2.3 Cloaking Compatibility <\/td>\n<\/tr>\n
61<\/td>\n6.3 Data Integrity Extension
Property Value
6.4 Examples <\/td>\n<\/tr>\n
72<\/td>\n7.1.1 Cloak – CLOAK (0x18)
Reason
Value Reason
PTx Responses:
Response Description <\/td>\n<\/tr>\n
73<\/td>\n7.1.2 Extended Control Error – XCE (0x19)
Control Error Value
FSK Responses
Response Description <\/td>\n<\/tr>\n
74<\/td>\n7.1.3 Specific Request – SRQ (0x20) <\/td>\n<\/tr>\n
75<\/td>\n7.1.4 Specific Request [Frequency Selection] – SRQ\/freqsel (0x20)
Frequency Selector
Value Description
FSK Responses
Response Reason <\/td>\n<\/tr>\n
76<\/td>\n7.1.5 Specific Request [Power Level] – SRQ\/egpl (0x20)
Load Power
FSK Responses
Response Reason <\/td>\n<\/tr>\n
77<\/td>\n7.1.6 Specific Request [Cloak Ping Delay – Low Byte] – SRQ\/cloakl (0x20)
Cloak Ping Delay (Low Byte)
FSK Responses
Response Reason <\/td>\n<\/tr>\n
78<\/td>\n7.1.7 Specific Request [Cloak Ping Delay – High Byte] – SRQ\/cloakh (0x20)
Cloak Ping Delay
FSK Responses
Response Reason <\/td>\n<\/tr>\n
79<\/td>\n7.1.8 Specific Request [Power Control Profile] – SRQ\/pcp (0x20)
Profile
Value Profile
FSK Responses
Response Reason <\/td>\n<\/tr>\n
80<\/td>\n7.1.9 Specific Request [Cloak Detect Ping Delay] – SRQ\/detect (0x20)
Cloak Detect Ping Delay
FSK Responses
Response Reason <\/td>\n<\/tr>\n
81<\/td>\n7.1.10 Specific Request [Proprietary Parameters] – SRQ\/MppProp (0x20)
Implementation Specific
FSK Responses
Response Reason <\/td>\n<\/tr>\n
82<\/td>\n7.1.11 Get Request – GET (0x28)
Parameter
FSK Response <\/td>\n<\/tr>\n
83<\/td>\n7.1.12 Enabled Data Streams – EDS (0x29)
Stream Bitmask
FSK Response <\/td>\n<\/tr>\n
84<\/td>\n7.1.13 Simultaneous Auxiliary Data Transport – SADT (multiple header codes)
Stream Number
FSK Responses
Response Description <\/td>\n<\/tr>\n
85<\/td>\n7.1.14 Simultaneous Data Stream Response – SDSR (0x38)
Stream Number
Type
FSK Responses <\/td>\n<\/tr>\n
86<\/td>\n7.1.15 Simultaneous Auxiliary Data Control – SADC (0x48)
Stream Number
Request
Value Description
Parameter
Request Field Parameter Value
FSK Response <\/td>\n<\/tr>\n
87<\/td>\n7.1.16 Report – REPORT (0x58:0)
Report ID
Value Report
Report Data
FSK Response <\/td>\n<\/tr>\n
88<\/td>\n7.1.17 Report [PRx Identification] (0x58:0)
Random Identifier
Mfg Reserved
FSK Responses
Response Description <\/td>\n<\/tr>\n
89<\/td>\n7.1.18 Power Loss Accounting (0x58:1)
Received Power
FSK Responses
Response Description <\/td>\n<\/tr>\n
90<\/td>\n7.1.19 Power Loss Accounting Parameters – PLAP (0x78)
FSK Responses
Response Description <\/td>\n<\/tr>\n
91<\/td>\n7.1.20 Qi MPP Extended Identification – MPP-XID (0x81)
Restricted
Alpha0 Rx
Alpha1 Rx
AlphaKth Rx
Mfg Reserved <\/td>\n<\/tr>\n
92<\/td>\n7.1.21 Extended Power Receiver Capabilities – ECAP (0x84)
Minimum Charging Power Level
Concurrent Data Streams
Data Stream Buffer Size
Mfg Reserved
FSK Responses
Response Description <\/td>\n<\/tr>\n
93<\/td>\n7.2 Power Transmitter data packets <\/td>\n<\/tr>\n
94<\/td>\n7.2.1 Error Status – ERR (0x01)
Error
Value Reason <\/td>\n<\/tr>\n
95<\/td>\n7.2.2 Cloak Request – CLOAK (0x1E:0)
Reason
Value Reason <\/td>\n<\/tr>\n
96<\/td>\n7.2.3 Regulation Control Status – RCS (0x1E:3)
Status
Value Description <\/td>\n<\/tr>\n
97<\/td>\n7.2.4 Charge Status – CHS (0x1F)
Charge Status Value
Value Description <\/td>\n<\/tr>\n
98<\/td>\n7.2.5 Get Request – GET (0x2E)
Parameter <\/td>\n<\/tr>\n
99<\/td>\n7.2.6 Enabled Data Streams – EDS (0x2F)
Stream Bitmask <\/td>\n<\/tr>\n
100<\/td>\n7.2.7 Inverter Voltage – INV (0x3F:0) <\/td>\n<\/tr>\n
101<\/td>\n7.2.8 Simultaneous Auxiliary Data Transport – SADT (multiple header codes)
Stream Number
Response <\/td>\n<\/tr>\n
102<\/td>\n7.2.9 Simultaneous Data Stream Response – SDSR (0x3F:1)
Stream Number
Type <\/td>\n<\/tr>\n
103<\/td>\n7.2.10 Estimated K – KEST (0x3F:2)
Estimated K <\/td>\n<\/tr>\n
104<\/td>\n7.2.11 Simultaneous Auxiliary Data Control – SADC (0x4F)
Stream Number
Request
Parameter
Response <\/td>\n<\/tr>\n
105<\/td>\n7.2.12 Power Loss Accounting Parameters – PLAP (0x5F) <\/td>\n<\/tr>\n
106<\/td>\n7.2.13 Extended Power Transmitter Identification – XID (0x8F:0)
Device Identifier
Mfg Reserved <\/td>\n<\/tr>\n
107<\/td>\n7.2.14 Extended Power Transmitter Extended Capabilities – ECAP (0x8F:1)
Potential Load Power
Negotiable Load Power
Power Limit Reason
Data Stream Buffer Size
Concurrent Data Streams
Response <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

BS EN IEC 63563-11 Qi Specification version 2.0 – Part 11. MPP Communications Protocol (Fast track)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2024<\/td>\n108<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":460335,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-460332","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/460332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/460335"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=460332"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=460332"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=460332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}