{"id":453328,"date":"2024-10-20T09:29:41","date_gmt":"2024-10-20T09:29:41","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-163-2023-3\/"},"modified":"2024-10-26T17:37:11","modified_gmt":"2024-10-26T17:37:11","slug":"ieee-c57-163-2023-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-163-2023-3\/","title":{"rendered":"IEEE C57.163-2023"},"content":{"rendered":"

Revision Standard – Active. The effects of geomagnetic disturbances (GMD) on power transformers when there is the presence of geomagnetically induced current (GIC) in a power transformer are described. Specification parameters and performance characteristics for power transformers to help minimize the risk and impact when GIC is present in the power system are established. The intent is to provide a background that can help evaluate the effect of GIC on a power transformer design and its GIC capability. This includes the evaluation techniques to determine the performance characteristics while under the influence of GIC.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std C57.163\u2122-2023 Front cover <\/td>\n<\/tr>\n
2<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
8<\/td>\nParticipants <\/td>\n<\/tr>\n
10<\/td>\nIntroduction <\/td>\n<\/tr>\n
12<\/td>\nContents <\/td>\n<\/tr>\n
13<\/td>\nList of Figures <\/td>\n<\/tr>\n
15<\/td>\nList of Tables <\/td>\n<\/tr>\n
16<\/td>\n1.\u2002Overview
1.1\u2002Scope
1.2\u2002Word usage <\/td>\n<\/tr>\n
17<\/td>\n2.\u2002Normative references
3.\u2002Definitions, acronyms, and abbreviations <\/td>\n<\/tr>\n
18<\/td>\n4.\u2002Background
4.1\u2002Geomagnetic disturbances <\/td>\n<\/tr>\n
19<\/td>\n4.2\u2002Typical signature\/profile of GIC <\/td>\n<\/tr>\n
21<\/td>\n4.3\u2002Effective GIC in autotransformers
5.\u2002Effects of GIC on power transformers
5.1\u2002Basics of the effects of dc current on power transformers <\/td>\n<\/tr>\n
25<\/td>\n5.2\u2002Magnetic effects of GIC <\/td>\n<\/tr>\n
26<\/td>\n5.3\u2002Thermal effects of GIC
5.4\u2002Other effects of GIC in transformers
6.\u2002Magnetic response of transformers to GIC <\/td>\n<\/tr>\n
27<\/td>\n6.1\u2002Magnetizing current pulse associated with core saturation <\/td>\n<\/tr>\n
28<\/td>\n6.2\u2002Inductive reactive power (vars) drawn by the transformer <\/td>\n<\/tr>\n
30<\/td>\n6.3\u2002Current harmonics associated with GIC <\/td>\n<\/tr>\n
31<\/td>\n7.\u2002Thermal response of transformers to GIC
7.1\u2002Thermal effects of dc current <\/td>\n<\/tr>\n
35<\/td>\n7.2\u2002The effect of the short duration of GIC pulses on transformer temperatures <\/td>\n<\/tr>\n
36<\/td>\n7.3\u2002Procedure for calculation of thermal response of windings and structural parts to a GIC profile <\/td>\n<\/tr>\n
37<\/td>\n7.4\u2002Examples of thermal performance of transformers due to a typical GIC profile <\/td>\n<\/tr>\n
40<\/td>\n7.5\u2002GIC thermal capability <\/td>\n<\/tr>\n
42<\/td>\n8.\u2002Evaluation of degree of susceptibility of transformers to thermal effects of GIC <\/td>\n<\/tr>\n
43<\/td>\n8.1\u2002Design-based susceptibility <\/td>\n<\/tr>\n
44<\/td>\n8.2\u2002GIC level-based susceptibility
8.3\u2002Total GIC susceptibility <\/td>\n<\/tr>\n
45<\/td>\n9.\u2002Specifications
9.1\u2002GIC signature
9.2\u2002Recommended hot-spot temperature limits
9.3\u2002Recommended design review requirements <\/td>\n<\/tr>\n
46<\/td>\n9.4\u2002Testing <\/td>\n<\/tr>\n
47<\/td>\n10.\u2002Transformer GIC monitoring
10.1\u2002Monitoring <\/td>\n<\/tr>\n
49<\/td>\n10.2\u2002Predicting part-cycle core saturation <\/td>\n<\/tr>\n
50<\/td>\n10.3\u2002Monitoring of GIC thermal impact on power transformers <\/td>\n<\/tr>\n
51<\/td>\nAnnex\u00a0A (informative) Simplified GIC signature <\/td>\n<\/tr>\n
52<\/td>\nAnnex\u00a0B (informative) Bibliography <\/td>\n<\/tr>\n
56<\/td>\nBack cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Guide for Establishing Power Transformer Capability while under Geomagnetic Disturbances (Published)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2023<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":453337,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-453328","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/453328","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/453337"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=453328"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=453328"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=453328"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}