{"id":403368,"date":"2024-10-20T05:05:47","date_gmt":"2024-10-20T05:05:47","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61753-111-082021-tc\/"},"modified":"2024-10-26T09:05:07","modified_gmt":"2024-10-26T09:05:07","slug":"bs-en-iec-61753-111-082021-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61753-111-082021-tc\/","title":{"rendered":"BS EN IEC 61753-111-08:2021 – TC"},"content":{"rendered":"

IEC 61752-111-08:2021 contains the minimum tests, test severities and measurement requirements which a sealed fibre optic closure need to meet in order to be categorised as meeting the IEC standard for category G – Ground, as defined in Table A.14 of IEC 61753-1:2018. Free breathing closures are not covered in this document. This first edition cancels and replaces IEC 61753-111-8 published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753-111-8: a) terms and definitions updated according to IEC 61753-1:2018 and IEC 61756-1:2019; b) test severities updated according to IEC 61753-1:2018; c) sealing tests are done with 20 kPa overpressure; d) pass-fail criterion of pressure loss during test added to mechanical sealing tests; e) vibration sealing test changed to 10 Hz, 3 mm amplitude and 1 000 000 cycles; f) reduced loads added in cable retention test for small diameter cables and tubes; g) reduced loads for cable axial compression test for small diameter cables; h) the duration of the cycles in torsion and bending test is added; i) free fall test removed (is covered by the optical shock test); j) crush resistance test of 1 000 N for 10 min is added; k) assembly and disassembly test: duration reduced to 5 cycles; l) resistance to solvents and contaminating fluids: added immersion in diesel with duration of 1 h and 24 h drying time and added immersion in petroleum jelly for 5 days; m) resistance to stress cracking solvents added for 5 days; n) duration of the change of temperature reduced to 12 cycles; o) water immersion test at 1 m for 7 days added.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n30454888 <\/td>\n<\/tr>\n
51<\/td>\nA-30395265 <\/td>\n<\/tr>\n
52<\/td>\nundefined <\/td>\n<\/tr>\n
55<\/td>\nAnnex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n
59<\/td>\nCONTENTS <\/td>\n<\/tr>\n
61<\/td>\nFOREWORD <\/td>\n<\/tr>\n
63<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
64<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
65<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
68<\/td>\n4 Abbreviated terms
5 General requirements
5.1 Storage, transportation and packaging
5.2 Installation and intervention <\/td>\n<\/tr>\n
69<\/td>\n5.3 Marking and identification
5.4 Materials <\/td>\n<\/tr>\n
70<\/td>\n5.5 Closure overpressure safety
6 Test
6.1 General
6.2 Test sample preparation
6.3 Test and measurement methods <\/td>\n<\/tr>\n
71<\/td>\n6.4 Pass\/fail criteria
6.5 Test report
7 Performance requirements
7.1 Sample size
7.2 Sealing, optical and visual examination pass\/fail criteria <\/td>\n<\/tr>\n
72<\/td>\nTables
Table 1 \u2013 Sealing, optical and visual examination pass\/fail criteria <\/td>\n<\/tr>\n
73<\/td>\n7.3 Sealing performance requirements
Table 2 \u2013 Sealing performance requirements <\/td>\n<\/tr>\n
76<\/td>\n7.4 Optical performance requirements
Table 3 \u2013 Optical performance requirements <\/td>\n<\/tr>\n
79<\/td>\nAnnex A (normative)Sample definition
A.1 Fibre type for test sample
Table A.1 \u2013 Fibre references for IEC 60793-2-50, sub-category B-652.D
Table A.2 \u2013 Fibre references for IEC 60793-2-50, sub-category B-657.A1 <\/td>\n<\/tr>\n
80<\/td>\nA.2 Closure optical test sample configuration
Figures
Figure A.1 \u2013 Track\/spur joint configuration sample
Table A.3 \u2013 Fibre references for IEC 60793-2-50, sub-category B-657.A2 <\/td>\n<\/tr>\n
81<\/td>\nFigure A.2 \u2013 Optical circuits in track\/spur joint closure
Figure A.3 \u2013 Distribution joint configuration sample <\/td>\n<\/tr>\n
82<\/td>\nFigure A.4 \u2013 Optical circuits in the distribution joint closure <\/td>\n<\/tr>\n
83<\/td>\nAnnex B (normative)Sample size
Table B.1 \u2013 Sample size <\/td>\n<\/tr>\n
84<\/td>\nAnnex C (normative)Intervention and reconfiguration\/resplicing
C.1 Handling of the closure
C.2 Movements of splice trays to gain access to the actual fibre circuits
C.3 Addition and connection of drop cables
C.4 Rearranging splices <\/td>\n<\/tr>\n
85<\/td>\nC.5 Rearranging optical connector sets, patchcords or pigtails (when applicable)
C.6 Addition and connection of extra FMS elements
C.7 Handling of the closure <\/td>\n<\/tr>\n
86<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Tracked Changes. Fibre optic interconnecting devices and passive components. Performance standard – Sealed closures for Category G. Ground<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2022<\/td>\n88<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":403377,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[650,2641],"product_tag":[],"class_list":{"0":"post-403368","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-180-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/403368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/403377"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=403368"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=403368"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=403368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}