{"id":399857,"date":"2024-10-20T04:45:50","date_gmt":"2024-10-20T04:45:50","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-pc57-12-91\/"},"modified":"2024-10-26T08:33:51","modified_gmt":"2024-10-26T08:33:51","slug":"ieee-pc57-12-91","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-pc57-12-91\/","title":{"rendered":"IEEE PC57.12.91"},"content":{"rendered":"
Revision Standard – Active – Draft. This revision addresses substantive changes to Clause 5, Clause 1 10, and Clause 11 of IEEE Std C57.12.91-2011 to reflect current practice in the testing procedures of dry-type transformers. This revision does not address transformer requirements and specific test criteria; rather they are contained in appropriate standards such as IEEE Std C57.12.01 or in user specifications.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C57.12.91\u2122-2020 Front cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Notice and Disclaimer of Liability Concerning the Use of IEEE Standards Documents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 1. Overview 1.1 Scope 1.2 Purpose <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 1.3 Word usage 2. Normative references <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 3. Definitions 4. General 4.1 Test definitions 4.2 Test requirements <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.3 Test sequence 4.4 Instrumentation 5. Resistance measurements 5.1 General 5.2 Measurements <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.3 Determination of cold temperature <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.4 Conversion of resistance measurements 5.5 Resistance measurement methods <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.6 Resistance measurement connections and reporting <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6. Polarity and phase-relation tests 6.1 General 6.2 Subtractive and additive polarity <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.3 Polarity tests\u2014single-phase transformers <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.4 Polarity and phase-relation tests\u2014polyphase transformers <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 7. Ratio test 7.1 General <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 7.2 Tolerances for ratio 7.3 Ratio test methods <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 8. Excitation losses and current 8.1 General <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 8.2 Excitation loss test <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 8.3 Waveform correction of excitation losses 8.4 Determination of excitation current <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 8.5 Frequency conversion of excitation losses and current 9. Load losses and impedance voltage 9.1 General 9.2 Factors affecting the values of load losses and impedance voltage <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 9.3 Tests for measuring load losses and impedance voltage <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 9.4 Calculation of load losses and impedance voltage from test data <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 9.5 Zero-phase-sequence impedance <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 10. Dielectric test 10.1 Factory dielectric tests <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 10.2 Dielectric tests in the field 10.3 Applied voltage tests <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 10.4 Induced voltage tests <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 10.5 Partial discharge tests <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 10.6 Impulse tests <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 10.7 Impulse tests on transformer neutrals 10.8 Detection of failure during impulse tests <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | 10.9 Insulation-power-factor tests <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | 10.10 Insulation-resistance tests <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 11. Temperature rise test 11.1 General <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 11.2 Ambient temperature measurements 11.3 Surface temperature measurements <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 11.4 Cold-resistance measurements 11.5 Hot-resistance measurements <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | 11.6 Calculation of average winding temperature rise <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | 11.7 Correction factors <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | 11.8 Temperature rise test loading methods <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 12. Short-circuit tests 12.1 Scope <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 12.2 Short-circuit testing techniques <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | 12.3 Test requirements 12.4 Test procedure <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | 12.5 Failure detection techniques <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | 12.6 Analysis of test results and visual inspection <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | 12.7 Proof of satisfactory performance <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | 12.8 Required information for transformer short-circuit test reports 13. Audible sound-level measurements 13.1 General <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | 13.2 Instrumentation <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | 13.3 Test conditions <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | 13.4 Microphone positions 13.5 Sound pressure level measurements <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | 13.6 Determination of audible sound level of a transformer 13.7 Presentation of results <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | 14. Mechanical design tests 14.1 General 14.2 Components involved in lifting or moving 14.3 Tests of sealed dry-type transformers 15. Calculated data 15.1 Reference temperature <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | 15.2 Total losses 15.3 Efficiency 15.4 Voltage regulation <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | 16. Minimum information to be included in certified test data 16.1 General 16.2 Order data <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | 16.3 Rating data 16.4 Test data 16.5 Calculated data 16.6 Certification statement and approval <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | Annex A (informative) Bibliography <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | Annex B (normative) 50\/60 Hz frequency conversion of measured performance parameters <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | Back cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Approved Draft Standard Test Code for Dry-Type Distribution and Power Transformers<\/b><\/p>\n |