{"id":373012,"date":"2024-10-20T02:31:56","date_gmt":"2024-10-20T02:31:56","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-pas-633432021\/"},"modified":"2024-10-26T04:26:18","modified_gmt":"2024-10-26T04:26:18","slug":"bsi-pd-iec-pas-633432021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-pas-633432021\/","title":{"rendered":"BSI PD IEC PAS 63343:2021"},"content":{"rendered":"
This document specifies technical requirements, methods of test and required test results for equipment implementing ASM part of the VHF Data exchange system (VDES) as defined in ITU-R M.2092.<\/p>\n
This document is intended to be the first step of development of standard(s) describing equipment that implement functions of VDES in any combination.<\/p>\n
\nNOTE All text of this document whose wording is identical to applicable external references such as ITU Recommendations is printed in italics, and the reference and associated paragraph numbers are indicated in brackets.<\/p>\n<\/blockquote>\n
\nNOTE The intention of text written in notation [Future: text] in this document is to include future placeholder for topics that are considered important even for the first implementations that may comply with this document.<\/p>\n<\/blockquote>\n
Requirements set in this document provide means to mitigate adverse interference to Automatic Identification System (AIS).<\/p>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 4<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 7<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 9<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 10<\/td>\n 3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
3.2 Abbreviated terms <\/td>\n<\/tr>\n\n 11<\/td>\n 4 General requirements and tests of equipment
4.1 Requirements (placeholder)
4.2 Methods of tests for general requirements
5 Performance requirements
5.1 Mobile station
5.1.1 Overview <\/td>\n<\/tr>\n\n 12<\/td>\n 5.1.2 General requirements <\/td>\n<\/tr>\n \n 13<\/td>\n 5.1.3 Technical requirements <\/td>\n<\/tr>\n \n 14<\/td>\n Tables
Table 1 \u2013 Slotted transmission spectrum for ASM <\/td>\n<\/tr>\n\n 15<\/td>\n Figures
Figure 1 \u2013 Slotted transmission spectrum for ASM <\/td>\n<\/tr>\n\n 16<\/td>\n Figure 2 \u2013 Transmitter power versus time characteristics for \u03c0\/4 QPSK (ASM)
Table 2 \u2013 Transmitter power versus time characteristics <\/td>\n<\/tr>\n\n 17<\/td>\n Table 3 \u2013 Receiver requirements without FEC (using Link ID 1) <\/td>\n<\/tr>\n \n 18<\/td>\n Table 4 \u2013 IEC 61162 Talker identifiers and sentence formatters used for input of data to Equipment for transmission to ASM VDL
Table 5 \u2013 IEC 61162 sentence formatters used to output ASM VDL <\/td>\n<\/tr>\n\n 19<\/td>\n Table 6 \u2013 IEC 61162 sentence formatters used to output equipment status and input related commands <\/td>\n<\/tr>\n \n 20<\/td>\n Table 7 \u2013 Use of ASM VDL messages <\/td>\n<\/tr>\n \n 21<\/td>\n Table 8 \u2013 Message 0 description <\/td>\n<\/tr>\n \n 23<\/td>\n Table 9 \u2013 Quiet time multiplier <\/td>\n<\/tr>\n \n 24<\/td>\n Figure 3 \u2013 Slot selection Criteria Flow Chart <\/td>\n<\/tr>\n \n 25<\/td>\n 5.2 Coast Station
5.2.1 Overview
5.2.2 General requirements
5.2.3 Technical requirements <\/td>\n<\/tr>\n\n 26<\/td>\n Table 10 \u2013 Slotted transmission spectrum for ASM <\/td>\n<\/tr>\n \n 27<\/td>\n Figure 4 \u2013 Slotted transmission spectrum for ASM <\/td>\n<\/tr>\n \n 28<\/td>\n Figure 5 \u2013 Transmitter power versus time characteristics for \u03c0\/4 QPSK (ASM)
Table 11 \u2013 Transmitter power versus time characteristics <\/td>\n<\/tr>\n\n 29<\/td>\n Table 12 \u2013 Receiver requirements without FEC (using Link ID 1) <\/td>\n<\/tr>\n \n 30<\/td>\n Table 13 \u2013 IEC 61162 Talker Identifiers and Sentence Formatters used for input of data to Equipment for transmission to ASM VDL
Table 14 \u2013 IEC 61162 Sentence Formatters used to output ASM VDL <\/td>\n<\/tr>\n\n 31<\/td>\n Table 15 \u2013 IEC 61162 Sentence Formatters used to output equipment status and input related commands <\/td>\n<\/tr>\n \n 32<\/td>\n Table 16 \u2013 Use of ASM VDL messages <\/td>\n<\/tr>\n \n 33<\/td>\n Table 17 \u2013 Message 0 description <\/td>\n<\/tr>\n \n 34<\/td>\n Table 18 \u2013 Quiet time multiplier <\/td>\n<\/tr>\n \n 35<\/td>\n Figure 6 \u2013 Slot selection criteria flow chart <\/td>\n<\/tr>\n \n 36<\/td>\n 5.3 AtoN Station
6 Methods of testing and required results
6.1 Mobile station
6.1.1 Test environment <\/td>\n<\/tr>\n\n 37<\/td>\n 6.1.2 Test signals
6.1.3 Environmental, power supply, special purpose and safety tests <\/td>\n<\/tr>\n\n 38<\/td>\n 6.1.4 Operational tests
Table 19 \u2013 Power supply test schedule <\/td>\n<\/tr>\n\n 39<\/td>\n 6.1.5 Specific tests of physical layer
Figure 7 \u2013 Test setup for frequency error measurement <\/td>\n<\/tr>\n\n 40<\/td>\n Table 20 \u2013 Carrier power, required results <\/td>\n<\/tr>\n \n 42<\/td>\n Table 21 \u2013 Used parameters and required results for ASM and VDE sensitivity tests
Table 22 \u2013 Used parameters and required results for ASM and VDE high input level tests <\/td>\n<\/tr>\n\n 43<\/td>\n Figure 8 \u2013 Test setup for adjacent channel selectivity
Table 23 \u2013 Additional channel combinations used for co-channel rejection tests <\/td>\n<\/tr>\n\n 44<\/td>\n Table 24 \u2013 Test signals used for adjacent channel selectivity tests <\/td>\n<\/tr>\n \n 45<\/td>\n Figure 9 \u2013 Measurement arrangement for intermodulation <\/td>\n<\/tr>\n \n 46<\/td>\n Figure 10 \u2013 Measurement arrangement for blocking or de-sensitisation
Table 25 \u2013 Frequencies for inter-modulation test
Table 26 \u2013 Test signals used for inter-modulation test <\/td>\n<\/tr>\n\n 47<\/td>\n 6.1.6 Specific tests of Link layer
Table 27 \u2013 Frequencies for blocking test
Table 28 \u2013 Test signals used for blocking test <\/td>\n<\/tr>\n\n 50<\/td>\n 6.1.7 Specific tests of Network layer <\/td>\n<\/tr>\n \n 51<\/td>\n 6.1.8 Specific tests of Transport layer
6.2 Coast station
6.2.1 Test environment <\/td>\n<\/tr>\n\n 52<\/td>\n 6.2.2 Test signals
6.2.3 Environmental, power supply, special purpose and safety tests <\/td>\n<\/tr>\n\n 53<\/td>\n 6.2.4 Operational tests <\/td>\n<\/tr>\n \n 54<\/td>\n 6.2.5 Specific tests of Physical layer
Figure 11 \u2013 Test setup for frequency error measurement <\/td>\n<\/tr>\n\n 55<\/td>\n Table 29 \u2013 Carrier power, required results <\/td>\n<\/tr>\n \n 57<\/td>\n Table 30 \u2013 Used parameters and required results for ASM and VDE sensitivity tests
Table 31 \u2013 Used parameters and required results for ASM and VDE high input level tests
Table 32 \u2013 Additional channel combinations used for co-channel rejection tests <\/td>\n<\/tr>\n\n 58<\/td>\n Figure 12 \u2013 Test setup for adjacent channel selectivity
Table 33 \u2013 Test signals used for adjacent channel selectivity tests <\/td>\n<\/tr>\n\n 60<\/td>\n Figure 13 \u2013 Measurement arrangement for intermodulation
Table 34 \u2013 Frequencies for inter-modulation test
Table 35 \u2013 Test signals used for inter-modulation test <\/td>\n<\/tr>\n\n 61<\/td>\n Figure 14 \u2013 Measurement arrangement for blocking or de-sensitisation
Table 36 \u2013 Frequencies for blocking test <\/td>\n<\/tr>\n\n 62<\/td>\n 6.2.6 Specific tests of Link layer
Table 37 \u2013 Test signals used for blocking test <\/td>\n<\/tr>\n\n 64<\/td>\n 6.2.7 Specific tests of Network layer <\/td>\n<\/tr>\n \n 65<\/td>\n 6.2.8 Specific tests of Transport layer
6.3 Tests for AtoN station <\/td>\n<\/tr>\n\n 66<\/td>\n Annex A (normative)Presentation Interface (PI) sentences
A.1 General
A.2 AAB \u2013 ASM Selective Addressed Message <\/td>\n<\/tr>\n\n 67<\/td>\n A.3 ABB \u2013 ASM Broadcast Message <\/td>\n<\/tr>\n \n 68<\/td>\n A.4 ADM \u2013 Received ASM VHF Data-Link Message <\/td>\n<\/tr>\n \n 69<\/td>\n A.5 ADO \u2013 ASM VHF Data-Link Own-Vessel transmission
A.6 AGB \u2013 ASM Geographical Multicast Message <\/td>\n<\/tr>\n\n 71<\/td>\n A.7 AMK \u2013 Addressed and broadcast ASM message acknowledgement
A.8 ASM \u2013 ASM Message Assembly <\/td>\n<\/tr>\n\n 73<\/td>\n A.9 ASQ \u2013 ASM Message Assembly Query
A.10 ACC \u2013 “ASM Coast Station Configuration command”
A.11 ??? \u2013 “additional ASM Coast Station Configuration” <\/td>\n<\/tr>\n\n 74<\/td>\n A.12 ??? \u2013 “ASM Coast Station Status sentence” <\/td>\n<\/tr>\n \n 75<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Maritime navigation and radiocommunication equipment and systems. VHF data exchange system. Requirements and methods of testing for stations including ASM functionality<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2021<\/td>\n 76<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":373020,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-373012","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/373012","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/373020"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=373012"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=373012"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=373012"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}