{"id":362282,"date":"2024-10-20T01:39:54","date_gmt":"2024-10-20T01:39:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-171272020\/"},"modified":"2024-10-26T02:36:34","modified_gmt":"2024-10-26T02:36:34","slug":"bs-en-171272020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-171272020\/","title":{"rendered":"BS EN 17127:2020"},"content":{"rendered":"

This document defines the minimum requirements to ensure the interoperability of hydrogen refuelling points, including refuelling protocols that dispense gaseous hydrogen to road vehicles (e.g. Fuel Cell Electric Vehicles)<\/i> that comply with legislation applicable to such vehicles.<\/p>\n

The safety and performance requirements for the entire hydrogen fuelling station, addressed in accordance with existing relevant European and national legislation, are not included in this document.<\/p>\n

\n
\n NOTE\n <\/div>\n

Guidance on considerations for hydrogen fuelling stations is provided in ISO 19880?1:2020<\/span><\/span> .<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
7<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
10<\/td>\n4 Abbreviated terms <\/td>\n<\/tr>\n
11<\/td>\n5 Characteristics and properties of hydrogen refuelling points <\/td>\n<\/tr>\n
12<\/td>\n5.3.1 General requirements for the fuelling protocol
5.3.2 Fuelling protocol process limits for light duty vehicle dispensing systems <\/td>\n<\/tr>\n
13<\/td>\n5.3.3 Fuelling protocol process limits for medium and heavy duty vehicle dispensing systems <\/td>\n<\/tr>\n
14<\/td>\n5.3.4 Vehicle to station communications
5.3.5 Dispenser Pressure Control Faults and over-pressure protection <\/td>\n<\/tr>\n
15<\/td>\n5.3.6 Dispenser temperature control faults
6 Inspection and validation of hydrogen refuelling points <\/td>\n<\/tr>\n
18<\/td>\nAnnex A (informative)Anticipated minimum vehicle characteristics <\/td>\n<\/tr>\n
20<\/td>\nAnnex B (informative)Countermeasures for unsuitable hydrogen fuelling protocols
B.1 General
B.2 Countermeasure examples <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Outdoor hydrogen refuelling points dispensing gaseous hydrogen and incorporating filling protocols<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":362291,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1027,2641],"product_tag":[],"class_list":{"0":"post-362282","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-71-100-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/362282","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/362291"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=362282"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=362282"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=362282"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}