{"id":279442,"date":"2024-10-19T18:51:34","date_gmt":"2024-10-19T18:51:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60601-1-82007a12013\/"},"modified":"2024-10-25T15:25:27","modified_gmt":"2024-10-25T15:25:27","slug":"bs-en-60601-1-82007a12013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60601-1-82007a12013\/","title":{"rendered":"BS EN 60601-1-8:2007+A1:2013"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope, object and related standards 1.1 Scope 1.2 Object 1.3 Related standards <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4 General requirements <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5 ME equipment identification marking and documents 5.1 Indicator lights and controls 5.2 Accompanying documents 6 Alarm systems 6.1 Alarm condition <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 6.2 Disclosures for intelligent alarm system Table 1 \u2013 Alarm condition priorities <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.3 Generation of alarm signals Table 2 \u2013 Characteristics of alarm indicator lights <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Table 3 \u2013 Characteristics of the burst of auditory alarm signals Table 4 \u2013 Characteristics of the pulse of auditory alarm signals <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figure 1 \u2013 Illustration of temporal characteristics of auditory alarm signals <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Untitled <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.4 Disclosure of delays 6.5 Alarm presets <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.6 Alarm limit <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.7 Alarm system security 6.8 Alarm signal inactivation states <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 6.9 Alarm reset 6.10 Non-latching and latching alarm signals Table 5 \u2013 Alarm signal inactivation states <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 6.11 Distributed alarm system Untitled <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 6.12 Alarm condition logging <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex A (informative) General guidance and rationale <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Figure A.1 \u2013 Graphical representation of components of alarm system delay <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Untitled <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Table A.1 \u2013 Reference interpretation of Table F.1 <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Table A.2 \u2013 Reference interpretation of Table F.2 <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Annex B (informative) Guide to marking and labelling requirements for ME equipment and ME systems Table B.1 \u2013 Cross-reference of marking <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Table B.2 \u2013 Cross-reference of accompanying documents Table B.3 \u2013 Cross-reference of instructions for use <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | Table B.4 \u2013 Cross-reference of technical description <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Annex C (normative) Symbols on marking Table C.1 \u2013 Graphical symbols for alarm systems <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Table C.2 \u2013 Alternative alarm system related markings <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | Annex D (informative) Guidance for auditory alarm signals Table D.1 \u2013 Attributes of perceived urgency <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | Annex E (informative) Verbal alarm signals <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | Annex F (normative) Reserved melodies for alarm signals Table F.1 \u2013 Equipment encoded auditory alarm signals categorized by alarm condition and priority complying with Table 3 and Table 4 Table F.2 \u2013 Auditory low priority alarm signal complying with Table 3 and Table 4 <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Medical electrical equipment – General requirements for basic safety and essential performance. Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems<\/b><\/p>\n |