{"id":233694,"date":"2024-10-19T15:14:18","date_gmt":"2024-10-19T15:14:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iec-62906-5-22016\/"},"modified":"2024-10-25T09:44:49","modified_gmt":"2024-10-25T09:44:49","slug":"bs-iec-62906-5-22016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iec-62906-5-22016\/","title":{"rendered":"BS IEC 62906-5-2:2016"},"content":{"rendered":"
This part of IEC 62906 specifies the standard measurement conditions and measurement methods for determining the monochromatic speckle contrast of laser display devices (LDDs). The LDDs may include hybrid types using both a laser or lasers, and spontaneous emission- based light sources, such as LEDs.<\/p>\n
\nNOTE The monochromatic speckle contrast measurements do not include image quality issues.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 6<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 8<\/td>\n 1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions
3.2 Abbreviations <\/td>\n<\/tr>\n\n 9<\/td>\n 4 Standard measuring conditions
4.1 General
4.2 Standard measuring environmental conditions
4.3 Measurement coordinate system <\/td>\n<\/tr>\n\n 10<\/td>\n 4.4 Darkroom conditions
4.5 Standard conditions of measuring equipment
4.5.1 General
Figures
Figure 1 \u2013 Coordinate system for projection direction and viewing direction <\/td>\n<\/tr>\n\n 11<\/td>\n 4.5.2 Adjustment of LDD
4.5.3 Conditions of measuring equipment <\/td>\n<\/tr>\n\n 12<\/td>\n 4.6 Screen conditions
4.6.1 General
4.6.2 Report
5 Measuring methods of speckle contrast
5.1 Speckle contrast measurement of still image
5.1.1 Purpose
5.1.2 Measuring conditions
5.1.3 Measuring the monochromatic speckle contrast of front projection <\/td>\n<\/tr>\n\n 13<\/td>\n Figure 2 \u2013 Example of measurement geometries for monochromatic speckle contrast of front projection <\/td>\n<\/tr>\n \n 14<\/td>\n 5.1.4 Measuring the monochromatic speckle contrast of rear projection
5.2 Calibration and diagnosis of the LMD
5.2.1 General
Figure 3 \u2013 Example of measurement geometries for monochromatic speckle contrast of rear projection <\/td>\n<\/tr>\n\n 15<\/td>\n 5.2.2 Calibration procedure and diagnosis for the highest Cs
5.2.3 Calibration procedure and diagnosis for the lowest Cs
Figure 4 \u2013 Example of measurement geometries for Cs calibration <\/td>\n<\/tr>\n\n 17<\/td>\n Annex A (informative) Spectral behaviour of the LD
A.1 Spectral behaviour of a single-longitudinal mode LD
A.2 Spectral behaviour of a multi-longitudinal mode LD
Figure A.1 \u2013 Example of spectral behaviour of a single-longitudinal mode LD
Figure A.2 \u2013 Example of spectral behaviour of a multi-longitudinal mode LD <\/td>\n<\/tr>\n\n 18<\/td>\n Annex B (informative) Recommendation on imaging sensor pixel size
Tables
Table B.1 \u2013 Example of ssubj <\/td>\n<\/tr>\n\n 19<\/td>\n Figure B.1 \u2013 Minimum subjective speckle grain size as a function of the F-number <\/td>\n<\/tr>\n \n 20<\/td>\n Annex C (informative) Fundamental formulation of speckle contrast and the effects of measurement variables
C.1 Fundamental formulation
C.2 Effect of observation distance and iris radius <\/td>\n<\/tr>\n\n 21<\/td>\n Figure C.1 \u2013 Measurement result of Cs by changing NAscreen-Iris <\/td>\n<\/tr>\n \n 22<\/td>\n Annex D (informative) Possible errors and their sources <\/td>\n<\/tr>\n \n 23<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Laser display devices – Optical measuring methods of speckle contrast<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2016<\/td>\n 26<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":233700,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-233694","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/233694","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/233700"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=233694"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=233694"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=233694"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}