{"id":227233,"date":"2024-10-19T14:46:17","date_gmt":"2024-10-19T14:46:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-604002017-tc\/"},"modified":"2024-10-25T08:46:25","modified_gmt":"2024-10-25T08:46:25","slug":"bs-en-604002017-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-604002017-tc\/","title":{"rendered":"BS EN 60400:2017 – TC"},"content":{"rendered":"
IEC 60400:2017 states the technical and dimensional requirements for lampholders for tubular fluorescent lamps and for starterholders, and the methods of test to be used in determining the safety and the fit of the lamps in the lampholders and the starters in the starterholders. This eighth edition cancels and replaces the seventh edition published in 2008, Amendment 1:2011 and Amendment 2:2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – alignment with ISO\/IEC drafting rules; – renumbering of clauses, tables and figures. This bilingual version (2017-12) corresponds to the monolingual English version, published in 2017-06. The French version of this standard has not been voted upon.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
145<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
158<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
162<\/td>\n | 4 General requirement <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | 5 General conditions for tests <\/td>\n<\/tr>\n | ||||||
164<\/td>\n | 6 Electrical rating 7 Classification <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | 8 Marking <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | 9 Protection against electric shock <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | 10 Terminals <\/td>\n<\/tr>\n | ||||||
171<\/td>\n | 11 Construction <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | 12 Resistance to dust and moisture <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | 13 Insulation resistance and electric strength Tables Table 1 \u2013 Minimum values of insulation resistance <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | 14 Endurance <\/td>\n<\/tr>\n | ||||||
179<\/td>\n | 15 Mechanical strength <\/td>\n<\/tr>\n | ||||||
181<\/td>\n | 16 Screws, current-carrying parts and connections Table 2 \u2013 Torque tests on screws <\/td>\n<\/tr>\n | ||||||
183<\/td>\n | 17 Creepage distances and clearances <\/td>\n<\/tr>\n | ||||||
184<\/td>\n | Table 3 \u2013 Minimum distances for AC sinusoidal voltages up to 30 kHz \u2013 Impulse withstand category II <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | 18 Resistance to heat, fire and tracking Table 4 \u2013 Minimum distances for rated ignition voltages or equivalent peak voltage UP <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | 19 Resistance to excessive residual stresses (season cracking) and to rusting <\/td>\n<\/tr>\n | ||||||
191<\/td>\n | Figures Figure 1 \u2013 Mounting jig for the testing of lampholders <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | Figure 2 \u2013 Mounting sheet <\/td>\n<\/tr>\n | ||||||
193<\/td>\n | Figure 3 \u2013 Fixture for the testing of lampholder flexibility <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | Figure 4 \u2013 Test caps G5, GX5 and G13 <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | Figure 5 \u2013 Impact test apparatus and mounting support <\/td>\n<\/tr>\n | ||||||
197<\/td>\n | Figure 6 \u2013 Test cap for the test of Clause 14 for lampholders 2GX13 <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | Figure 7 \u2013 Ball-pressure apparatus Figure 8 \u2013 Bracket for fixing lampholders for the impact test <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | Figure 9 \u2013 Test cap and test assembly for testing of resistance to heatof lampholders G13, G5 and GX5 with T marking <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | Figure 10 \u2013 Dimensions of starterholder and holder <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | Figure 11 \u2013 \u201cGo\u201d plug gauges for starterholders <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | Figure 12 \u2013 Plug gauge for starterholders for testing contact making and retention <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | Figure 13 \u2013 Special plug gauge for starterholders for testing contact making <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | Figure 14 \u2013 Test cap for the test of Clause 14 for lampholders G5 and GX5 Figure 15 \u2013 Test cap for the test of Clause 14 for lampholders G13 <\/td>\n<\/tr>\n | ||||||
207<\/td>\n | Figure 16 \u2013 Test cap for the test of Clause 14 for lampholders 2G13 Figure 18 \u2013 Test cap for the test ofClause 14 for lampholders Fa6 Figure 17 \u2013 Test cap for the test ofClause 14 for lampholders G20 <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | Figure 19 \u2013 Test cap for the test of Clause 14 for lampholders G10q, GU10q and GZ10q Figure 20 \u2013 Test cap for the test of Clause 14 for lampholders Fa8 <\/td>\n<\/tr>\n | ||||||
209<\/td>\n | Figure 21 \u2013 Test starter for the test of Clause 14 <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | Figure 22 \u2013 Test cap for the test of Clause 14 for lampholders R17d <\/td>\n<\/tr>\n | ||||||
211<\/td>\n | Figure 23 \u2013 Test cap for the test of Clause 14 for lampholders 2G11 <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | Figure 24 \u2013 Test cap for the test of Clause 14 for lampholders G23 and GX23 <\/td>\n<\/tr>\n | ||||||
213<\/td>\n | Figure 25 \u2013 Test cap for the test of Clause 14 for lampholders GR8 Figure 26 \u2013 Test cap for the test of Clause 14 for lampholders GR10q <\/td>\n<\/tr>\n | ||||||
214<\/td>\n | Figure 27 \u2013 Test cap for the test of Clause 14 for lampholders GX10q and GY10q <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | Figure 28 \u2013 Test cap for the test of Clause 14 for lampholders G24, GX24 and GY24 <\/td>\n<\/tr>\n | ||||||
216<\/td>\n | Figure 29 \u2013 Test cap for the test of Clause 14 for lampholders G32 and GY32 <\/td>\n<\/tr>\n | ||||||
217<\/td>\n | Figure 30 \u2013 Test cap for the test of 18.1 for lampholders G23 <\/td>\n<\/tr>\n | ||||||
218<\/td>\n | Figure 31 \u2013 Test cap for the test of 18.1 for lampholders GR8 <\/td>\n<\/tr>\n | ||||||
219<\/td>\n | Figure 32 \u2013 Test cap for the test of 18.1 for lampholders GR10q <\/td>\n<\/tr>\n | ||||||
220<\/td>\n | Figure 33 \u2013 Test cap for the test of 18.1 for lampholders GX10q <\/td>\n<\/tr>\n | ||||||
221<\/td>\n | Figure 34 \u2013 Test cap for the test of 18.1 for lampholders GY10q <\/td>\n<\/tr>\n | ||||||
222<\/td>\n | Figure 35 \u2013 Test cap for the test of 18.1 for lampholders 2G11 <\/td>\n<\/tr>\n | ||||||
223<\/td>\n | Figure 36 \u2013 Test cap for the test of 18.1 for lampholders GX23 <\/td>\n<\/tr>\n | ||||||
224<\/td>\n | Figure 37 \u2013 Test cap for the test of 18.1 for lampholders G24, GX24 and GY24 (1 of 2) <\/td>\n<\/tr>\n | ||||||
226<\/td>\n | Figure 38 \u2013 Test cap for the test of 18.1 for lampholders G32, GX32 and GY32 (1 of 2) <\/td>\n<\/tr>\n | ||||||
228<\/td>\n | Figure 39 \u2013 Test cap for the test of Clause 14 for lampholders 2G8 <\/td>\n<\/tr>\n | ||||||
229<\/td>\n | Figure 40 \u2013 Test cap for the test of Clause 14 for lampholders GX53 <\/td>\n<\/tr>\n | ||||||
230<\/td>\n | Figure 41 \u2013 Standard test finger (according to IEC\u00a060529:2014) <\/td>\n<\/tr>\n | ||||||
231<\/td>\n | Figure 42 \u2013 Test cap for the test of Clause 14 for lampholders W4.3×8.5d <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | Figure 43 \u2013 Test cap for the test of Clause 14 for lampholders GR14q <\/td>\n<\/tr>\n | ||||||
233<\/td>\n | Figure 44 \u2013 Test cap for the test of Clause 14 for lampholders G28d <\/td>\n<\/tr>\n | ||||||
234<\/td>\n | Figure 45 \u2013 Test cap for the test of Clause 14 for lampholders 2GX11 <\/td>\n<\/tr>\n | ||||||
235<\/td>\n | Figure 46 \u2013 Test probes for checking gasket sleeves on lampholders for higher IP protection <\/td>\n<\/tr>\n | ||||||
236<\/td>\n | Annex A (normative) Examples of lampholders covered by IEC 60400 Table A.1 \u2013 Examples of lampholders covered by IEC\u00a060400 <\/td>\n<\/tr>\n | ||||||
237<\/td>\n | Annex B (normative) Season cracking\/corrosion test B.1 General B.2 Test cabinet B.3 Test solution Table B.1 \u2013 pH adjustment <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | B.4 Test procedure <\/td>\n<\/tr>\n | ||||||
239<\/td>\n | Annex C (informative) Protection against electric shock \u2013 Explanatory details for the installation of lampholders according to 9.2 Figure C.1 \u2013 Examples of lampholders <\/td>\n<\/tr>\n | ||||||
240<\/td>\n | Annex D (informative) Clauses containing new or more stringent requirements with respect to the previous edition <\/td>\n<\/tr>\n | ||||||
241<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Lampholders for tubular fluorescent lamps and starterholders<\/b><\/p>\n |