{"id":217275,"date":"2024-10-19T14:05:34","date_gmt":"2024-10-19T14:05:34","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-6262-62005\/"},"modified":"2024-10-25T07:12:06","modified_gmt":"2024-10-25T07:12:06","slug":"bs-6262-62005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-6262-62005\/","title":{"rendered":"BS 6262-6:2005"},"content":{"rendered":"

This part of BS 6262 gives information and recommendations for vertical glazing in the external walls and interiors of buildings, with respect to:<\/p>\n

    \n
  1. \n

    structural sealant glazing;<\/p>\n<\/li>\n

  2. \n

    bolt fixed structural glazing;<\/p>\n<\/li>\n

  3. \n

    frameless doors and entrances;<\/p>\n<\/li>\n

  4. \n

    mirrors.<\/p>\n<\/li>\n

  5. \n

    Bolt fixed structural glazing with countersunk holes is not specifically covered.<\/p>\n<\/li>\n<\/ol>\n

    \n

    NOTE some guidance is also given on non-vertical use of mirrors.<\/p>\n<\/blockquote>\n

    These recommendations do not apply to:<\/p>\n

      \n
    1. \n

      patent glazing (see BS 5516-1);<\/p>\n<\/li>\n

    2. \n

      glass in non-vertical applications (see BS 5516-2);<\/p>\n<\/li>\n

    3. \n

      glazing for furniture and fittings (see BS 7376 and BS 7449);<\/p>\n<\/li>\n

    4. \n

      glazing for commercial greenhouses (see BS 5502-21);<\/p>\n<\/li>\n

    5. \n

      glazing for domestic greenhouses.<\/p>\n<\/li>\n<\/ol>\n

      Requirements for standards of workmanship for the application of sealants have been published separately as BS 8000-16, and therefore this subject is not dealt with in this standard.<\/p>\n

      PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
      PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
      1<\/td>\nBRITISH STANDARD <\/td>\n<\/tr>\n
      2<\/td>\nCommittees responsible for this British Standard <\/td>\n<\/tr>\n
      3<\/td>\nContents <\/td>\n<\/tr>\n
      5<\/td>\n1 Scope
      2 Normative references
      3 Terms and definitions
      glazing (noun)
      glazing (verb)
      insulating glass unit
      pane <\/td>\n<\/tr>\n
      6<\/td>\nplastics glazing sheet material
      sealant bite
      vertical glazing
      four edge bonded structural sealant glazing
      two edge bonded structural sealant glazing
      Definition of sealant bite in structural sealant glazing
      4 Structural sealant glazing
      4.1 General <\/td>\n<\/tr>\n
      7<\/td>\n4.2 Design principles <\/td>\n<\/tr>\n
      8<\/td>\nPrinciples of a structural sealant glazing system
      4.3 Compatibility of materials <\/td>\n<\/tr>\n
      9<\/td>\n4.4 Assembly
      5 Glazing using structural glass fins
      5.1 General
      5.2 Design
      5.3 Performance of glass with fin supports <\/td>\n<\/tr>\n
      10<\/td>\nFin thickness <\/td>\n<\/tr>\n
      11<\/td>\nDetermination of annealed float glass fin width to resist the design wind load <\/td>\n<\/tr>\n
      12<\/td>\n5.4 Fixing
      6 Suspended glazing with annealed glass <\/td>\n<\/tr>\n
      13<\/td>\nFin support box
      7 Bolt fixed structural glazing
      7.1 General <\/td>\n<\/tr>\n
      14<\/td>\nPrinciples of a toughened glass infill panel bolted connection <\/td>\n<\/tr>\n
      15<\/td>\nRelationship between bolt size, spreader plates and glass thickness
      7.2 Bolt fixing of glass in barriers <\/td>\n<\/tr>\n
      16<\/td>\nTypical localized fixing clamp for free standing glass barrier <\/td>\n<\/tr>\n
      17<\/td>\nTypical continuous fixing clamp for free standing glass barrier
      7.3 Frameless doors and door assemblies
      Recommended frameless toughened door thicknesses <\/td>\n<\/tr>\n
      18<\/td>\nPrinciples of a cantilever fin support <\/td>\n<\/tr>\n
      19<\/td>\nSpacing of bolts in cantilevered fin support systems
      7.4 Toughened glass suspended assemblies
      8 Mirrors
      8.1 General <\/td>\n<\/tr>\n
      20<\/td>\n8.2 Safety
      8.3 Glass mirrors <\/td>\n<\/tr>\n
      21<\/td>\n8.4 Plastics mirrors <\/td>\n<\/tr>\n
      22<\/td>\n(informative) Simplified calculation of sealant dimensions for structural sealant glazing
      (informative) Simplified calculation of sealant dimensions for structural sealant glazing
      General
      Structural sealant dimensions
      Symbols
      Limitations of the method <\/td>\n<\/tr>\n
      23<\/td>\nCalculation <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

      Glazing for buildings – Code of practice for special applications<\/b><\/p>\n\n\n\n\n
      Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
      BSI<\/b><\/a><\/td>\n2005<\/td>\n26<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":217278,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1158,2641],"product_tag":[],"class_list":{"0":"post-217275","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-81-040-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/217275","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/217278"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=217275"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=217275"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=217275"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}