{"id":191130,"date":"2024-10-19T12:04:38","date_gmt":"2024-10-19T12:04:38","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-14-20-handbook-2019\/"},"modified":"2024-10-25T04:32:52","modified_gmt":"2024-10-25T04:32:52","slug":"nfpa-14-20-handbook-2019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-14-20-handbook-2019\/","title":{"rendered":"NFPA 14 20 Handbook 2019"},"content":{"rendered":"

Expanded and renamed, the Stationary Fire Pumps and Standpipe Systems Handbook addresses NFPA 20 and NFPA 14 requirements for all types of fire pumps and standpipe systems. Order this practical resource for expert advice on helping to keep fire pumps and standpipe systems in compliance and functioning error-free! Developed by NFPA\u00ae and featuring commentary written by leading authorities in the field, the expanded Stationary Fire Pumps and Standpipe Systems Handbook is based on the 2019 edition of NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection, and the 2016 edition of NFPA 14, Standard for the Installation of Standpipe and Hose Systems. Access a wealth of information and support in a single source. The Handbook provides advanced guidance relating to all types of equipment, along with water supply availability and reliability. An exclusive Overview of Fire Pump Configurations includes examples of fire pump arrangements and explains the purpose of the components in each arrangement. The overview also features a full-color diagram that helps designers and engineers understand how multistage, multiport pumps can eliminate the need for pumps in series, potentially saving money. The Handbook is also organized into the following four parts: Part I includes the complete 2019 edition of NFPA 20, plus expert commentary. This edition introduces first-time sections on Pressure Control at the end of Chapter 4, General Requirements; Fire Pump Curve and Analysis at the end of Chapter 6, Centrifugal Pumps; and Electrical Power Supply for Fire Pumps in Chapter 9, Electric Drive for Pumps. Part II features the complete 2016 edition of NFPA 14, plus expert commentary. Part III: Water Supply Requirements, Water Demand, Hydrants, Tanks, and Piping contains text from selected water supply documents with original supporting explanations and advice. Material includes: Section 1 with the full 2019 edition of NFPA 291, Recommended Practice for Fire Flow Testing and Marking of Hydrants, plus commentary Section 2 with the full 2019 edition of NFPA 24, Standard for the Installation of Private Fire Service Mains and Their Appurtenances, plus commentary Section 3 with Sections 18.4 and 18.5 from the 2018 edition of NFPA 1, Fire Code, plus commentary Section 4 with extracts from the 2018 edition of NFPA 22, Standard for Water Tanks for Private Fire Protection, plus commentary Part IV: Supplements address: Considerations When Designing and Selecting a Fire Pump Interrelationship of NFPA Standards Pertaining to a Fire Pump Installation, including a full-color, pull-out illustration of a fire pump installation Commissioning and Inspection, Testing, and Maintenance Forms for Fire Pumps NEC\u00ae Article 695, Fire Pumps Design features make information more accessible. Just like in the standards, shading and change symbols tell you where a change has occurred. “Ask the AHJ” and FAQs help installers avoid common errors. “Design Alerts” call out commentary relevant to design issues. Calculation Example feature is separate from commentary. “See More” feature includes pointers that help you navigate the Handbook. Summary of Technical Changes tables for NFPA 20 and NFPA 14 each provide a brief overview of major code changes from the previous edition to the current edition. Expand your knowledge with this comprehensive, one-stop source for system designers, installers, contractors, engineers, facility managers, inspectors, and AHJs<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
2<\/td>\nCopyright <\/td>\n<\/tr>\n
3<\/td>\nContents <\/td>\n<\/tr>\n
7<\/td>\nPreface <\/td>\n<\/tr>\n
9<\/td>\nAcknowledgments <\/td>\n<\/tr>\n
11<\/td>\nDedication <\/td>\n<\/tr>\n
13<\/td>\nAbout the Contributors <\/td>\n<\/tr>\n
19<\/td>\nAbout the Editors <\/td>\n<\/tr>\n
21<\/td>\nNFPA 20 and NFPA 14Summary of Technical Changes <\/td>\n<\/tr>\n
29<\/td>\nAn Overview of Fire PumpConfigurations <\/td>\n<\/tr>\n
45<\/td>\nPART I – NFPA\u00ae 20, Standard for theInstallation of Stationary Pumpsfor Fire Protection, with Commentary <\/td>\n<\/tr>\n
47<\/td>\n1 Administration
1.1 Scope <\/td>\n<\/tr>\n
48<\/td>\n1.2 Purpose <\/td>\n<\/tr>\n
49<\/td>\n1.3 Application
1.4 Retroactivity
1.5 Equivalency <\/td>\n<\/tr>\n
50<\/td>\n1.6 Units <\/td>\n<\/tr>\n
53<\/td>\n2 Referenced Publications
2.1 General
2.2 NFPA Publications
2.3 Other Publications <\/td>\n<\/tr>\n
55<\/td>\n2.4 References for Extracts in
\n Mandatory Sections <\/td>\n<\/tr>\n
57<\/td>\n3 Definitions
3.1 General
3.2 NFPA Official Definitions <\/td>\n<\/tr>\n
59<\/td>\n3.3 General Definitions <\/td>\n<\/tr>\n
87<\/td>\n4 General Requirements
4.1 Pumps <\/td>\n<\/tr>\n
88<\/td>\n4.2 Approval Required <\/td>\n<\/tr>\n
91<\/td>\n4.3 Pump Operation <\/td>\n<\/tr>\n
93<\/td>\n4.4 Fire Pump Unit Performance <\/td>\n<\/tr>\n
94<\/td>\n4.5 Certified Shop Test <\/td>\n<\/tr>\n
96<\/td>\n4.6 Liquid Supplies <\/td>\n<\/tr>\n
100<\/td>\n4.7 Pumps, Drivers, and Controllers <\/td>\n<\/tr>\n
106<\/td>\n4.8 Self-Regulating Variable Speed Fire Pump
\n Units <\/td>\n<\/tr>\n
107<\/td>\n4.9 Multistage Multiport Pump
4.10 Centrifugal Fire Pump Capacities <\/td>\n<\/tr>\n
109<\/td>\n4.11 Nameplate <\/td>\n<\/tr>\n
110<\/td>\n4.12 Pressure Gauges <\/td>\n<\/tr>\n
112<\/td>\n4.13 Circulation Relief Valve <\/td>\n<\/tr>\n
114<\/td>\n4.14 Equipment Protection <\/td>\n<\/tr>\n
119<\/td>\n4.15 Pipe and Fittings <\/td>\n<\/tr>\n
122<\/td>\n4.16 Suction Pipe and Fittings <\/td>\n<\/tr>\n
138<\/td>\n4.17 Discharge Pipe and Fittings <\/td>\n<\/tr>\n
143<\/td>\n4.18 Valve Supervision <\/td>\n<\/tr>\n
144<\/td>\n4.19 Protection of Piping Against Damage Due to
\n Movement
4.20 Relief Valves for Centrifugal Pumps <\/td>\n<\/tr>\n
152<\/td>\n4.21 Pumps Arranged in Series <\/td>\n<\/tr>\n
155<\/td>\n4.22 Water Flow Test Devices <\/td>\n<\/tr>\n
166<\/td>\n4.23 Steam Power Supply Dependability
4.24 Shop Tests
4.25 Pump Shaft Rotation <\/td>\n<\/tr>\n
167<\/td>\n4.26 Other Signals <\/td>\n<\/tr>\n
168<\/td>\n4.27 Pressure Maintenance (Jockey or Make-Up)
\n Pumps <\/td>\n<\/tr>\n
172<\/td>\n4.28 Summary of Centrifugal Fire Pump
\n Data <\/td>\n<\/tr>\n
176<\/td>\n4.29 Backflow Preventers and Check
\n Valves <\/td>\n<\/tr>\n
178<\/td>\n4.30 Earthquake Protection <\/td>\n<\/tr>\n
179<\/td>\n4.31 Packaged Fire Pump Assemblies <\/td>\n<\/tr>\n
182<\/td>\n4.32 Pressure Actuated Controller Pressure Sensing
\n Lines <\/td>\n<\/tr>\n
184<\/td>\n4.33 Break Tanks
4.34 Field Acceptance Test of Pump Units <\/td>\n<\/tr>\n
185<\/td>\n4.35 Automated Inspection, Testing, and Distance
\n Monitoring of Devices, Meters, and
\n Equipment <\/td>\n<\/tr>\n
191<\/td>\n5 Fire Pumps for High-Rise Buildings
5.1 General <\/td>\n<\/tr>\n
192<\/td>\n5.2 Equipment Access
5.3 Water Supply Tanks <\/td>\n<\/tr>\n
193<\/td>\n5.4 Fire Pump Test Arrangement <\/td>\n<\/tr>\n
194<\/td>\n5.5 Alternate Power
5.6 Very Tall Buildings <\/td>\n<\/tr>\n
201<\/td>\n6 Centrifugal Pumps
6.1 General <\/td>\n<\/tr>\n
209<\/td>\n6.2 Factory and Field Performance <\/td>\n<\/tr>\n
213<\/td>\n6.3 Fittings <\/td>\n<\/tr>\n
218<\/td>\n6.4 Foundation and Setting
6.5 Connection to Driver and Alignment <\/td>\n<\/tr>\n
231<\/td>\n7 Vertical Shaft Turbine\u2013Type Pumps
7.1 General <\/td>\n<\/tr>\n
233<\/td>\n7.2 Water Supply <\/td>\n<\/tr>\n
241<\/td>\n7.3 Pump <\/td>\n<\/tr>\n
247<\/td>\n7.4 Installation <\/td>\n<\/tr>\n
249<\/td>\n7.5 Driver <\/td>\n<\/tr>\n
254<\/td>\n7.6 Operation and Maintenance <\/td>\n<\/tr>\n
257<\/td>\n8 Positive Displacement Pumps
8.1 General <\/td>\n<\/tr>\n
263<\/td>\n8.2 Foam Concentrate and Additive
\n Pumps <\/td>\n<\/tr>\n
265<\/td>\n8.3 Water Mist System Pumps
8.4 Water Mist Positive Displacement Pumping
\n Units <\/td>\n<\/tr>\n
268<\/td>\n8.5 Fittings <\/td>\n<\/tr>\n
273<\/td>\n8.6 Pump Drivers <\/td>\n<\/tr>\n
275<\/td>\n8.7 Controllers <\/td>\n<\/tr>\n
276<\/td>\n8.8 Foundation and Setting
8.9 Driver Connection and Alignment <\/td>\n<\/tr>\n
277<\/td>\n8.10 Flow Test Devices <\/td>\n<\/tr>\n
279<\/td>\n9 Electric Drive for Pumps <\/td>\n<\/tr>\n
280<\/td>\n9.1 General <\/td>\n<\/tr>\n
282<\/td>\n9.2 Normal Power <\/td>\n<\/tr>\n
290<\/td>\n9.3 Alternate Power <\/td>\n<\/tr>\n
292<\/td>\n9.4 Voltage Drop <\/td>\n<\/tr>\n
295<\/td>\n9.5 Motors <\/td>\n<\/tr>\n
304<\/td>\n9.6 On-Site Standby Generator Systems <\/td>\n<\/tr>\n
307<\/td>\n9.7 Junction Boxes <\/td>\n<\/tr>\n
308<\/td>\n9.8 Listed Electrical Circuit Protective System to
\n Controller Wiring <\/td>\n<\/tr>\n
309<\/td>\n9.9 Raceway Terminations <\/td>\n<\/tr>\n
317<\/td>\n10 Electric-Drive Controllers and
\n Accessories
10.1 General <\/td>\n<\/tr>\n
325<\/td>\n10.2 Location <\/td>\n<\/tr>\n
333<\/td>\n10.3 Construction <\/td>\n<\/tr>\n
340<\/td>\n10.4 Components <\/td>\n<\/tr>\n
356<\/td>\n10.5 Starting and Control <\/td>\n<\/tr>\n
373<\/td>\n10.6 Controllers Rated in Excess of 600 V <\/td>\n<\/tr>\n
378<\/td>\n10.7 Limited Service Controllers <\/td>\n<\/tr>\n
379<\/td>\n10.8 Power Transfer for Alternate Power
\n Supply <\/td>\n<\/tr>\n
390<\/td>\n10.9 Controllers for Additive Pump Motors <\/td>\n<\/tr>\n
391<\/td>\n10.10 Controllers with Variable Speed Pressure
\n Limiting Control or Variable Speed Suction
\n Limiting Control <\/td>\n<\/tr>\n
405<\/td>\n11 Diesel Engine Drive
11.1 General <\/td>\n<\/tr>\n
406<\/td>\n11.2 Engines <\/td>\n<\/tr>\n
431<\/td>\n11.3 Pump Room <\/td>\n<\/tr>\n
434<\/td>\n11.4 Fuel Supply and Arrangement <\/td>\n<\/tr>\n
441<\/td>\n11.5 Engine Exhaust <\/td>\n<\/tr>\n
443<\/td>\n11.6 Diesel Engine Driver System
\n Operation <\/td>\n<\/tr>\n
447<\/td>\n12 Engine Drive Controllers
12.1 Application <\/td>\n<\/tr>\n
451<\/td>\n12.2 Location <\/td>\n<\/tr>\n
452<\/td>\n12.3 Construction <\/td>\n<\/tr>\n
458<\/td>\n12.4 Components <\/td>\n<\/tr>\n
473<\/td>\n12.5 Battery Recharging <\/td>\n<\/tr>\n
474<\/td>\n12.6 Battery Chargers <\/td>\n<\/tr>\n
478<\/td>\n12.7 Starting and Control <\/td>\n<\/tr>\n
493<\/td>\n12.8 Air-Starting Engine Controllers <\/td>\n<\/tr>\n
495<\/td>\n13 Steam Turbine Drive
13.1 General <\/td>\n<\/tr>\n
498<\/td>\n13.2 Turbine <\/td>\n<\/tr>\n
500<\/td>\n13.3 Installation <\/td>\n<\/tr>\n
503<\/td>\n14 Acceptance Testing, Performance, and
\n Maintenance
14.1 Hydrostatic Tests and Flushing <\/td>\n<\/tr>\n
512<\/td>\n14.2 Field Acceptance Tests <\/td>\n<\/tr>\n
548<\/td>\n14.3 Record Drawings, Test Reports, Manuals,
\n Special Tools, and Spare Parts <\/td>\n<\/tr>\n
549<\/td>\n14.4 Periodic Inspection, Testing, and
\n Maintenance <\/td>\n<\/tr>\n
550<\/td>\n14.5 Component Replacement <\/td>\n<\/tr>\n
553<\/td>\nAnnex A Explanatory Material <\/td>\n<\/tr>\n
555<\/td>\nAnnex B Possible Causes of Pump
\n Troubles <\/td>\n<\/tr>\n
561<\/td>\nAnnex C Fire Pump Room Connectivity <\/td>\n<\/tr>\n
631<\/td>\nAnnex D Material Extracted by NFPA 70,
\n Article 695 <\/td>\n<\/tr>\n
635<\/td>\nAnnex E Informational References <\/td>\n<\/tr>\n
639<\/td>\nPART II – NFPA\u00ae 14, Standard for the Installationof Standpipe and Hose Systems, withCommentary <\/td>\n<\/tr>\n
641<\/td>\n1 Administration
1.1 Scope
1.2 Purpose <\/td>\n<\/tr>\n
642<\/td>\n1.3 Retroactivity
1.4 Equivalency <\/td>\n<\/tr>\n
643<\/td>\n1.5 Units <\/td>\n<\/tr>\n
645<\/td>\n2 Referenced Publications
2.1 General
2.2 NFPA Publications <\/td>\n<\/tr>\n
646<\/td>\n2.3 Other Publications <\/td>\n<\/tr>\n
647<\/td>\n2.4 References for Extracts in Mandatory
\n Sections <\/td>\n<\/tr>\n
649<\/td>\n3 Definitions
3.1 General
3.2 NFPA Official Definitions <\/td>\n<\/tr>\n
651<\/td>\n3.3 General Definitions <\/td>\n<\/tr>\n
661<\/td>\n4 System Components and Hardware
4.1 General <\/td>\n<\/tr>\n
662<\/td>\n4.2 Pipe and Tube <\/td>\n<\/tr>\n
664<\/td>\n4.3 Fittings <\/td>\n<\/tr>\n
665<\/td>\n4.4 Joining of Pipe and Fittings <\/td>\n<\/tr>\n
674<\/td>\n4.5 Valves
4.6 Hose Stations <\/td>\n<\/tr>\n
678<\/td>\n4.7 Hose Connections <\/td>\n<\/tr>\n
679<\/td>\n4.8 Fire Department Connections <\/td>\n<\/tr>\n
680<\/td>\n4.9 Pressure-Regulating Devices <\/td>\n<\/tr>\n
681<\/td>\n4.10 Signs <\/td>\n<\/tr>\n
683<\/td>\n5 System Requirements
5.1 General
5.2 Automatic and Semiautomatic Dry
\n Systems <\/td>\n<\/tr>\n
691<\/td>\n5.3 Classes of Standpipe Systems <\/td>\n<\/tr>\n
693<\/td>\n5.4 Required Type of System <\/td>\n<\/tr>\n
695<\/td>\n5.5 Gauges <\/td>\n<\/tr>\n
697<\/td>\n5.6 Waterflow and Supervisory Alarms <\/td>\n<\/tr>\n
699<\/td>\n6 Installation Requirements
6.1 Location and Protection of Piping <\/td>\n<\/tr>\n
702<\/td>\n6.2 Underground Piping
6.3 Gate Valves and Check Valves <\/td>\n<\/tr>\n
709<\/td>\n6.4 Fire Department Connections <\/td>\n<\/tr>\n
711<\/td>\n6.5 Support of Piping
6.6 Installation of Signs
6.7 Signs for Water Supply Pumps
6.8 Hydraulic Design Information Sign <\/td>\n<\/tr>\n
713<\/td>\n7 Design
7.1 General <\/td>\n<\/tr>\n
716<\/td>\n7.2 Pressure Limitation <\/td>\n<\/tr>\n
721<\/td>\n7.3 Locations of Hose Connections <\/td>\n<\/tr>\n
728<\/td>\n7.4 Number of Standpipes
7.5 Interconnection of Standpipes
7.6 Minimum Sizes for Standpipes and Branch
\n Lines, Class I and Class III Standpipes <\/td>\n<\/tr>\n
729<\/td>\n7.7 System Design and Sizing of Pipe for Delivery
\n of System Demand
7.8 Minimum and Maximum Pressure
\n Limits <\/td>\n<\/tr>\n
731<\/td>\n7.9 Standpipe System Zones <\/td>\n<\/tr>\n
733<\/td>\n7.10 Flow Rates <\/td>\n<\/tr>\n
740<\/td>\n7.11 Drains and Test Riser <\/td>\n<\/tr>\n
741<\/td>\n7.12 Fire Department Connections <\/td>\n<\/tr>\n
743<\/td>\n8 Plans and Calculations
8.1 Plans and Specifications <\/td>\n<\/tr>\n
747<\/td>\n8.2 Hydraulic Calculations <\/td>\n<\/tr>\n
752<\/td>\n8.3 Hydraulic Calculation Procedures <\/td>\n<\/tr>\n
757<\/td>\n9 Water Supply
9.1 Required Water Supply <\/td>\n<\/tr>\n
758<\/td>\n9.2 Minimum Supply for Class I, Class II, and
\n Class III Systems <\/td>\n<\/tr>\n
759<\/td>\n10 Water Supply Testing
10.1 Water Supply Evaluation <\/td>\n<\/tr>\n
760<\/td>\n10.2 Procedure <\/td>\n<\/tr>\n
761<\/td>\n11 System Acceptance
11.1 General <\/td>\n<\/tr>\n
767<\/td>\n11.2 Flushing of Piping <\/td>\n<\/tr>\n
768<\/td>\n11.3 Hose Threads
11.4 Hydrostatic Tests <\/td>\n<\/tr>\n
770<\/td>\n11.5 Flow Tests <\/td>\n<\/tr>\n
776<\/td>\n11.6 Manual Valve Test
11.7 Alarm and Supervision Tests
11.8 Record Drawings, Test Reports, and
\n Manuals <\/td>\n<\/tr>\n
777<\/td>\n11.9 Signs <\/td>\n<\/tr>\n
779<\/td>\n12 Buildings Under Construction
12.1 General <\/td>\n<\/tr>\n
780<\/td>\n12.2 Fire Department Connections
12.3 Other System Features
12.4 Support of Piping <\/td>\n<\/tr>\n
781<\/td>\n12.5 Hose Connections
12.6 Extension of System Piping
12.7 Temporary Installations
12.8 Timing of Water Supply Installation <\/td>\n<\/tr>\n
782<\/td>\n12.9 Protection of Hose Connections and Fire
\n Department Connections <\/td>\n<\/tr>\n
783<\/td>\n13 System Testing, Inspection, and
\n Maintenance
13.1 General <\/td>\n<\/tr>\n
787<\/td>\nAnnex A Explanatory Material <\/td>\n<\/tr>\n
789<\/td>\nAnnex B Informational References <\/td>\n<\/tr>\n
791<\/td>\nPART III – Water Supply Requirements, Water Demand, Hydrants, Tanks, and Piping <\/td>\n<\/tr>\n
793<\/td>\nSection 1 Complete Text of NFPA\u00ae 291, Recommended
\n Practice for Fire Flow Testing and
\n Marking of Hydrants, 2019 Edition, with
\n Commentary <\/td>\n<\/tr>\n
819<\/td>\nSection 2 Complete Text of NFPA\u00ae 24, Standard for
\n the Installation of Private Fire Service Mains
\n and Their Appurtenances, 2019 Edition, with
\n Commentary <\/td>\n<\/tr>\n
905<\/td>\nSection 3 Sections 18.4 and 18.5 from NFPA\u00ae 1,
\n Fire Code Handbook, 2018 Edition, with
\n Commentary <\/td>\n<\/tr>\n
923<\/td>\nSection 4 Extracts with Commentary from NFPA\u00ae 22,
\n Standard for Water Tanks for Private Fire
\n Protection, 2018 Edition <\/td>\n<\/tr>\n
961<\/td>\nPART IV – Supplements <\/td>\n<\/tr>\n
963<\/td>\nSupplement 1 Considerations When Designing and
\n Selecting a Fire Pump <\/td>\n<\/tr>\n
975<\/td>\nSupplement 2 Interrelationship of NFPA
\n Standards Pertaining to a Fire Pump
\n Installation <\/td>\n<\/tr>\n
985<\/td>\nSupplement 3 Commissioning and Inspection,
\n Testing, and Maintenance Forms for
\n Fire Pumps <\/td>\n<\/tr>\n
1007<\/td>\nSupplement 4 Article 695 of NFPA 70\u00ae, National
\n Electrical Code\u00ae Handbook, 2017 Edition,
\n Fire Pumps <\/td>\n<\/tr>\n
1021<\/td>\nNFPA 20 Index <\/td>\n<\/tr>\n
1031<\/td>\nNFPA 14 Index <\/td>\n<\/tr>\n
1035<\/td>\nImportant Notices and Legal Disclaimers <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

NFPA 14 & 20: Stationary Fire Pumps and Standpipe Systems Handbook<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NFPA<\/b><\/a><\/td>\n2019<\/td>\n1035<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":191132,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-191130","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/191130","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/191132"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=191130"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=191130"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=191130"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}