{"id":111550,"date":"2024-10-18T16:12:53","date_gmt":"2024-10-18T16:12:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-17-2013\/"},"modified":"2024-10-24T22:01:55","modified_gmt":"2024-10-24T22:01:55","slug":"ieee-c57-17-2013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-17-2013\/","title":{"rendered":"IEEE C57.17 2013"},"content":{"rendered":"
New IEEE Standard – Active. The electrical characteristics and mechanical features of liquid-immersed transformers 69 kV or less (but not limited to 69 kV), used for supplying electric power to direct arc-melting furnaces are covered in this standard.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C57.17-2012 Front cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Patents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Important notice 1. Overview 1.1 Scope 1.2 Purpose 1.3 Word usage <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 2. Normative references 3. Definitions <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4. Ratings 4.1 General requirements for ratings <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.2 Transformer kVA ratings 4.3 High- and low-voltage ratings <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 4.4 Current ratings 4.5 Vector relationships 5. Insulation levels 5.1 High-voltage terminals and windings <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.2 Low-voltage terminals and windings <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6. Impedance voltage 6.1 Background 6.2 Reactor impedance <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 7. Connections 7.1 High-voltage connections 7.2 Low-voltage connections 8. Testing 8.1 Routine tests <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 8.2 Ratio tests 8.3 Polarity and phase relation <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 8.4 Resistance measurements 8.5 No-load losses and excitation current 8.6 Load losses and impedance tests <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 8.7 Temperature rise tests 8.8 Dielectric tests <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 8.9 Short-circuit tests 9. Construction 9.1 Specifications 9.2 Terminals <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 9.3 Accessories <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 9.4 Designations and nameplates 9.5 De-energized tap changers <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 9.6 Load tap changers <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 9.7 Tank and case construction <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Annex A (informative) Direct-current arc-furnace transformers <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Annex B (informative) \nIEEE Guide for Arc-Furnace Protection B.1 Introduction B.2 Overvoltage caused by the switching-on operation <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | B.3 Overvoltage caused by the switching-off operation <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | B.4 Protective devices <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | B.5 Maintenance <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Annex C (informative) Replacement and remanufacturing of low-voltage bus bars C.1 Introduction C.2 Terminals <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Annex D (informative) Bid document checklist D.1 Introduction D.2 Technical information D.3 Special requirements or conditions <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | D.4 Additional information <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Annex E (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard Requirements for Arc Furnace Transformers<\/b><\/p>\n |