Contains the latest and most useful information from manufacturers, fabricators, and corrosion specialists on the use and application of thermoplastic materials. This fully illustrated manual provides full construction details and standards for PVC ducts of 2”, 4”, 6” and 10” wg positive and negative. It gives guidance in understanding these synthetic materials, as well as assistance in determining their strengths, corrosion resistance and advantages over other materials. A model specification enables one to easily prepare custom project documents for installation of PVC air handling systems. Also covered are polypropylene and polyethylene, CPVC, LDPE, HDPE, UHMW, ABS, acrylics, and PVDF.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | FOREWORD |
5 | TASK FORCE |
6 | NOTICE TO USERS |
9 | TABLE OF CONTENTS |
13 | CHAPTER 1 INTRODUCTION 1.1 PLASTIC MATERIALS 1.2 THERMOPLASTICS 1.3 THERMOSETS |
14 | 1.4 PLASTIC DUCT USE 1.5 PURPOSE 1.6 CONTENTS |
16 | CHAPTER 2 MATERIAL SELECTION AND APPLICATIONS GUIDE 2.1 GENERAL APPLICATIONS AND DESCRIPTION OF THERMOPLASTIC MATERIALS 2.1.1 INTRODUCTION 2.1.2 APPLICATIONS 2.1.3 PROPERTIES 2.1.4 INDUSTRIAL PROCESSES 2.1.5 CHOOSING MATERIALS |
17 | 2.2 PVC — POLYVINYL CHLORIDE 2.2.1 CELL CLASSIFICATION 2.2.2 CELL NUMBERS |
20 | 2.2.3 METHODS OF MANUFACTURING 2.2.4 EXTRUDED SHEET 2.2.5 PRESS LAMINATED SHEET 2.2.6 EXTRUDED ROUND DUCT |
21 | 2.2.7 STRUCTURAL SHAPES 2.2.8 PVC WELDING ROD 2.2.9 PVC SOLVENT CEMENTS 2.3 CPVC — CHLORINATED POLYVINYL CHLORIDE |
22 | 2.4 PP — POLYPROPYLENE 2.5 LDPE — LOW DENSITY POLYETHYLENE 2.5.1 USAGE 2.6 HDPE — HIGH DENSITY POLYETHYLENE (LINEAR) |
23 | 2.7 UHMW — POLYETHYLENE (ULTRA HIGH MOLECULAR WEIGHT) 2.8 ABS — ACRYLONITRILE BUTADIENE STYRENE 2.9 ACRYLICS 2.10 PVDF — POLYVINYLDIENE |
24 | 2.11 TEFLON 2.12 ELASTOMERS 2.12.1 EPDM — ETHYLENE PROPYLENE DIENE MONOMER 2.12.2 VITON 2.12.3 BUNA N 2.13 APPLICABLE STANDARDS FOR THERMOPLASTIC MATERIALS & PRODUCTS |
25 | 2.14 PHYSICAL PROPERTIES |
29 | 2.15 CORROSION RESISTANCE 2.15.1 RATINGS 2.15.2 COMPATIBILITY 2.15.3 CORROSION — METAL 2.15.4 CORROSION — PLASTICS |
30 | 2.15.5 CORROSION MEASUREMENT 2.15.6 ORGANIC ATTACK 2.15.7 STRESS CRACKING |
31 | 2.15.8 TEMPERATURE 2.16 FLAMMABILITY |
33 | CHAPTER 3 STANDARDS OF CONSTRUCTION FOR PVC DUCT SYSTEMS 3.1 PURPOSE 3.2 SCOPE 3.3 DESIGN CONSIDERATIONS |
34 | 3.4 MATERIALS 3.4.1 PLASTIC COMPOUNDS 3.4.2 RIGID SHEETS 3.4.3 EXTRUDED DUCT 3.5 METHODS OF CONSTRUCTION GENERAL 3.6 DUCT SIZES AND TOLERANCES 3.6.1 WALL THICKNESS 3.6.2 ROUND DUCT |
35 | 3.6.3 RECTANGULAR DUCT 3.6.4 FITTINGS 3.6.5 SQUARENESS OF ENDS 3.7 REINFORCEMENT — EXTERNAL 3.7.1 LOCATION 3.7.2 REINFORCEMENT OF FITTINGS 3.7.3 RIGIDITY 3.7.4 TYPE 3.7.5 REINFORCING MATERIALS |
36 | 3.7.6 ATTACHMENT 3.8 REINFORCEMENT — INTERNAL 3.8.1 LOCATION 3.8.2 REINFORCEMENT MATERIALS 3.8.3 FLANGE SELECTION |
38 | ROUND DUCT — GENERAL NOTES |
48 | RECTANGULAR DUCT — GENERAL NOTES |
58 | 3.9 WELDING 3.9.1 HOT GAS FILLER ROD WELDING 3.9.2 THERNAL BUTT WELDING 3.9.3 SOLVENT WELDING |
59 | 3.10 JOINTS AND SEAMS 3.10.1 LONGITUDINAL SEAMS 3.10.2 TRANSVERSE JOINTS 3.10.2.1 BELL AND SPIGOT 3.10.2.2 SLEEVE JOINTS 3.11 FITTING TRANSITIONS AND BRANCHES 3.11.1 ELBOWS, ROUND DUCT |
60 | 3.11.2 ELBOWS, RECTANGULAR DUCT 3.11.3 TURNING VANES 3.11.4 OFFSETS 3.11.5 TRANSITIONS AND REDUCERS 3.11.6 BRANCHES ENTERING MAIN 3.12 FLANGES 3.12.1 FLANGE ATTACHMENTS |
61 | 3.13 GASKETS 3.14 FLEXIBLE CONNECTIONS 3.14.1 LOCATION 3.14.2 MATERIAL |
63 | 3.14.3 CONSTRUCTION 3.14.4 SUPPORT 3.15 EXPANSION JOINTS |
64 | 3.16 DUCT HANGERS AND SUPPORT 3.17 FUME HOODS 3.18 DAMPERS 3.18.1 VOLUME DAMPERS |
65 | 3.18.2 BACK-DRAFT DAMPERS 3.18.3 FIRE DAMPERS 3.19 ACCESS OPENING AND END CAPS 3.20 DRAINS 3.21 VENTILATOR HEADS AND LOUVERS 3.22 AUXILIARY EQUIPMENT |
94 | CHAPTER 4 GUIDE SPECIFICATIONS FOR PVC AIR-HANDLING SYSTEMS GENERAL DRAWINGS SEISMIC RESTRAINT PROVISIONS |
95 | 1.00 GENERAL PROVISIONS 1.01 WORK INCLUDED |
96 | 1.02 WORK EXCLUDED 1.03 COORDINATION OF WORK |
97 | 1.04 SUBMITALS |
98 | 1.05 EQUIPMENT IDENTIFICATION 1.06 REFERENCED DOCUMENTS |
99 | 2.00 AIR DISTRIBUTION PVC DUCTWORK 2.01 MATERIALS |
100 | 2.02 SIZE 2.03 LOCATION OF ACCESS DOORS 2.04 LOCATION OF REGULATING DAMPERS 2.05 FIRE DAMPERS 2.06 LOCATION OF REGULATING DAMPERS 2.07 LOCATION OF EXPANSION JOINTS |
101 | 2.08 LOCATIONS OF DRAINS 3.00 EQUIPMENT AND ACCESSORIES 3.01 FANS (SUPPLY, RETURN AND EXHAUST) 3.02 AIR OR FUME SCRUBBERS |
102 | 3.03 DUST COLLECTORS 3.04 FILTERS 3.05 HOODS, FUME 3.06 LOUVERS AND VENTILATOR HEADS 3.07 MOTORS AND BASES 3.08 SOUND ATTENUATORS |
103 | 3.09 BALANCING AND ADJUSTING 3.10 GUARANTEE |
105 | CHAPTER 5 CHEMICAL RESISTANCE GUIDE |
118 | CHAPTER 6 GLOSSARY OF TERMS |
123 | APPENDICES APPENDIX A — CRITERIA FOR THE ESTABLISHMENT OF PVC DUCT REINFORCEMENT TABLES A.1.0 TEST METHODS FOR REINFORCEMENT TABLE A.1.1 ROUND DUCT UNDER NEGATIVE PRESSURE |
124 | A.1.2 ROUND DUCT UNDER POSITIVE PRESSURE A.1.3 RECTANGULAR DUCT UNDER NEGATIVE PRESSURE |
126 | A.1.4 RECTANGULAR DUCT UNDER POSITIVE PRESSURE A.1.5 OTHER CRITERIA |
127 | APPENDIX B — LISTED REFERENCES |
130 | INDEX |