Shopping Cart

No products in the cart.

MI BuildingCode 09 2009

$67.44

Michigan Building Code

Published By Publication Date Number of Pages
MI 2009 661
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

A fully integrated custom code based on the 2009 International Building Code® (IBC®). The scope of this code covers all buildings except three-storey one- and two family dwellings and townhomes.

PDF Catalog

PDF Pages PDF Title
1 2009 MICHIGAN BUILDING CODE
2 2009 MICHIGAN BUILDING CODE INCOPRATING THE 2009 EDITION OF THE INTERNATIONAL BUILDING CODE TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 SAMPLE ORDINANCE
8 TABLE OF CONTENTS
14 CHAPTER 1: SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
15 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
16 SECTION 105 PERMITS
18 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 SUBMITTAL DOCUMENTS
19 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
20 SECTION 110 INSPECTIONS
SECTION 111 CERTIFICATE OF OCCUPANCY
21 SECTION 112 SERVICE UTILITIES
SECTION 113 BOARD OF APPEALS
SECTION 114 VIOLATIONS
22 SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
24 CHAPTER 2: DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
36 CHAPTER 3: USE AND OCCUPANCY CLASSIFICATION
SECTION 301 GENERAL
SECTION 302 CLASSIFICATION
SECTION 303 ASSEMBLY GROUP A
37 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
38 SECTION 307 HIGH-HAZARD GROUP H
39 [F] TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
40 [F] TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
41 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
46 SECTION 308 INSTITUTIONAL GROUP I
47 SECTION 309 MERCANTILE GROUP M
48 SECTION 310 RESIDENTIAL GROUP R
SECTION 311 STORAGE GROUP S
49 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
50 CHAPTER 4: SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
EQUATION 4-1
53 SECTION 403 HIGH-RISE BUILDINGS
54 TABLE 403.2.4 MINIMUM BOND STRENGTH
56 SECTION 404 ATRIUMS
57 SECTION 405 UNDERGROUND BUILDINGS
58 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
60 TABLE 406.3.5 OPEN PARKING GARAGES AREA AND HEIGHT
62 SECTION 407 GROUP I-2
63 SECTION 408 GROUP I-3
65 SECTION 409 MOTION PICTURE PROJECTION ROOMS
66 SECTION 410 STAGES AND PLATFORMS
67 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
68 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
69 TABLE 412.3.2 HEIGHT AND AREA LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
70 [F] TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
71 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
72 [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
73 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
TABLE [F] 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA
74 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
75 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
78 [F] TABLE 415.3.1 MINIMUM SEPARATION DISTANCES FOR BUILDINGS CONTAINING EXPLOSIVE MATERIALS
79 TABLE 415.3.1—continued MINIMUM SEPARATION DISTANCES FOR BUILDINGS CONTAINING EXPLOSIVE MATERIALS
80 [F] TABLE 415.3.2 DETACHED BUILDING REQUIRED
82 [F] TABLE 415.8.2.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
87 SECTION 416 APPLICATION OF FLAMMABLE FINISHES
SECTION 417 DRYING ROOMS
88 SECTION 418 ORGANIC COATINGS
SECTION 419 LIVE/WORK UNITS
SECTION 420 GROUPS I-1, R-1, R-2, R-3
89 SECTION 421 HYDROGEN CUTOFF ROOMS
SECTION 422 AMBULATORY HEALTH CARE FACILITIES
90 SECTION 423 STORM SHELTERS
92 CHAPTER 5: GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT
93 TABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREAS
94 SECTION 505 MEZZANINES
95 SECTION 506 BUILDING AREA MODIFICATIONS
EQUATION 5-1
EQUATION 5-2
96 SECTION 507 UNLIMITED AREA BUILDINGS
97 SECTION 508 MIXED USE AND OCCUPANCY
98 TABLE 508.2.5 INCIDENTAL ACCESSORY OCCUPANCIES
99 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (hours)
100 SECTION 509 SPECIAL PROVISIONS
102 CHAPTER 6: TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
SECTION 602 CONSTRUCTION CLASSIFICATION
103 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
TABLE 602.4 WOOD MEMBER SIZE
104 SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION
106 CHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
107 SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
108 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
110 SECTION 705 EXTERIOR WALLS
EQUATION 7-1
111 FIGURE 705.7 EQUIVALENT OPENING FACTOR
112 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
113 EQUATION 7-2
114 SECTION 706 FIRE WALLS
TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
116 SECTION 707 FIRE BARRIERS
TABLE 707.3.9 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
117 SECTION 708 SHAFT ENCLOSURES
120 SECTION 709 FIRE PARTITIONS
121 SECTION 710 SMOKE BARRIERS
122 SECTION 711 SMOKE PARTITIONS
SECTION 712 HORIZONTAL ASSEMBLIES
123 SECTION 713 PENETRATIONS
126 SECTION 714 FIRE-RESISTANT JOINT SYSTEMS
SECTION 715 OPENING PROTECTIVES
127 TABLE 715.4 FIRE DOOR AND FIRE SHUTTER FIRE PROTECTION RATINGS
130 TABLE 715.5 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
TABLE 715.5.4 LIMITING SIZES OF WIRED GLASS PANELS
SECTION 716 DUCTS AND AIR TRANSFER OPENINGS
131 TABLE 716.3.2.1 FIRE DAMPER RATING
134 SECTION 717 CONCEALED SPACES
137 SECTION 718 FIRE-RESISTANCE REQUIREMENTSFOR PLASTER
SECTION 719 THERMAL- AND SOUND-INSULATING MATERIALS
138 SECTION 720 PRESCRIPTIVE FIRE RESISTANCE
SECTION 721 CALCULATED FIRE RESISTANCE
139 TABLE 720.1(1)MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
140 TABLE 720.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
141 TABLE 720.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODSFOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
142 TABLE 720.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODSFOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
143 TABLE 720.1(2)RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
144 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
145 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
146 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
147 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
148 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
149 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
150 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
151 TABLE 720.1(3)MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
152 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
153 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
154 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
155 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
156 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
157 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
158 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
159 TABLE 721.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE ORPRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
160 EQUATION 7-3
TABLE 721.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
FIGURE 721.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
EQUATION 7-4
161 TABLE 721.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R O.59
FIGURE 721.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
162 TABLE 721.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 721.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
163 TABLE 721.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 721.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 721.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 721.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
164 FIGURE 721.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 721.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
165 TABLE 721.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 721.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 721.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc(APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 721.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTH
166 TABLE 721.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
TABLE 721.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
167 EQUATION 7-6
TABLE 721.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
168 EQUATION 7-7
TABLE 721.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 721.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
169 TABLE 721.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 721.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
EQUATION 7-9
EQUATION 7-10
170 TABLE 721.4.1(3) VALUES OF Rn0.59
TABLE 721.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 721.4.1(5) REINFORCED MASONRY LINTELS
TABLE 721.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-11
171 FIGURE 721.5.1(1) DETERMINATION OF THE HEATED PERIMETEROF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
FIGURE 721.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
172 EQUATION 7-13
FIGURE 721.5.1(3) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
FIGURE 721.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNSPROTECTED WITH VARIOUS THICKNESSES OFTYPE X GYPSUM WALLBOARD
FIGURE 721.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
173 EQUATION 7-14
EQUATION 7-15
FIGURE 721.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa,b
EQUATION 7-16
174 FIGURE 721.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
FIGURE 721.5.2 DETERMINATION OF THE HEATED PERIMETERFor SI: 1 inch = 25.4 mm. OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
175 TABLE 721.5.1(1) W/D RATIOS FOR STEEL COLUMNS
176 TABLE 721.5.1(2) PROPERTIES OF CONCRETE
TABLE 721.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
177 TABLE 721.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D)FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
178 TABLE 721.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D)FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
179 TABLE 721.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
180 TABLE 721.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
181 TABLE 721.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
182 TABLE 721.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa[FIGURE 721.5.1(6)(c)]
TABLE 721.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa[FIGURE 721.5.1(6)(c)]
183 TABLE 721.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa[FIGURE 721.5.1(6)(a)]
TABLE 721.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa[FIGURE 721.5.1(6)(a)]
184 TABLE 721.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
185 TABLE 721.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 721.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WAL
TABLE 721.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMING
TABLE 721.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
186 EQUATION 7-18
EQUATION 7-19
EQUATION 7-20
EQUATION 7-21
FIGURE 721.6.3(1) LOAD FIGURE
FIGURE 721.6.3(2) EFFECTIVE LENGTH FACTORS
188 CHAPTER 8: INTERIOR FINISHES
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 WALL AND CEILING FINISHES
190 TABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
191 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
[F] SECTION 806 DECORATIVE MATERIALS AND TRIM
192 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
194 CHAPTER 9: FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
SECTION 902 DEFINITIONS
197 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
198 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
200 TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
202 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
203 SECTION 905 STANDPIPE SYSTEMS
206 SECTION 906 PORTABLE FIRE EXTINGUISHERS
TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE
TABLE 906.1—continued ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE
207 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH
208 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
217 TABLE 907.5.2.3.3 VISIBLE ALARMS
SECTION 908 EMERGENCY ALARM SYSTEMS
218 SECTION 909 SMOKE CONTROL SYSTEMS
220 EQUATION 9-1
EQUATION 9-2
EQUATION 9-3
225 SECTION 910 SMOKE AND HEAT VENTS
226 TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
EQUATION 9-4
227 SECTION 911 FIRE COMMAND CENTER
SECTION 912 FIRE DEPARTMENT CONNECTIONS
228 SECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
229 SECTION 915 EMERGENCY RESPONDER RADIO COVERAGE
SECTION 916 CARBON MONOXIDE DETECTORS
230 CHAPTER 10: MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
231 SECTION 1003 GENERAL MEANS OF EGRESS
232 SECTION 1004 OCCUPANT LOAD
233 TABLE 1004.1.1 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
234 SECTION 1005 EGRESS WIDTH
SECTION 1006 MEANS OF EGRESS ILLUMINATION
235 SECTION 1007 ACCESSIBLE MEANS OF EGRESS
237 SECTION 1008 DOORS, GATES AND TURNSTILES
238 TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS
243 SECTION 1009 STAIRWAYS
246 SECTION 1010 RAMPS
247 SECTION 1011 EXIT SIGNS
248 SECTION 1012 HANDRAILS
249 SECTION 1013 GUARDS
250 SECTION 1014 EXIT ACCESS
251 SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
252 SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
253 TABLE 1016.1 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1017 AISLES
254 SECTION 1018 CORRIDORS
TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
255 SECTION 1019 EGRESS BALCONIES
SECTION 1020 EXITS
SECTION 1021 NUMBER OF EXITS AND CONTINUITY
TABLE 1021.1 MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD
256 TABLE 1021.2 STORIES WITH ONE EXIT
SECTION 1022 EXIT ENCLOSURES
258 SECTION 1023 EXIT PASSAGEWAYS
259 SECTION 1024 DELETED
SECTION 1025 HORIZONTAL EXITS
SECTION 1026 EXTERIOR EXIT RAMPS AND STAIRWAYS
260 SECTION 1027 EXIT DISCHARGE
261 SECTION 1028 ASSEMBLY
262 TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
264 TABLE 1028.10.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
266 SECTION 1029 EMERGENCY ESCAPE AND RESCUE
268 CHAPTER 11: ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 SCOPING REQUIREMENTS
269 SECTION 1104 ACCESSIBLE ROUTE
270 SECTION 1105 ACCESSIBLE ENTRANCES
271 SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
TABLE 1106.1 ACCESSIBLE PARKING SPACES
272 SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
273 TABLE 1107.6.1.1 ACCESSIBLE DWELLING AND SLEEPING UNITS
275 SECTION 1108 SPECIAL OCCUPANCIES
TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
276 TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
277 SECTION 1109 OTHER FEATURES AND FACILITIES
279 TABLE 1109.11.2 ACCESSIBLE CHECK-OUT AISLES
280 SECTION 1110 SIGNAGE
282 CHAPTER 12: INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION
283 SECTION 1204 TEMPERATURE CONTROL
SECTION 1205 LIGHTING
284 SECTION 1206 YARDS OR COURTS
SECTION 1207 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS
285 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 SURROUNDING MATERIALS
SECTION 1211 TOILET ROOM REQUIREMENTS
286 CHAPTER 13: ENERGY EFFICIENCY
SECTION 1301 GENERAL
288 CHAPTER 14: EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 PERFORMANCE REQUIREMENTS
289 SECTION 1404 MATERIALS
290 SECTION 1405 INSTALLATION OF WALL COVERINGS
TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
TABLE 1405.3.1 CLASS III VAPOR RETARDERS
294 SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1406.2.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE VENEERS
295 SECTION 1407 METAL COMPOSITE MATERIALS (MCM)
296 SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
298 CHAPTER 15: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
SECTION 1503 WEATHER PROTECTION
299 SECTION 1504 PERFORMANCE REQUIREMENTS
300 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
SECTION 1506 MATERIALS
301 SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
TABLE 1507.2.7.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158a
TABLE 1507.2.7.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161
302 TABLE 1507.2.9.2 VALLEY LINING MATERIAL
304 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
305 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
306 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
307 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
308 TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
309 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
310 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
SECTION 1508 ROOF INSULATION
TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
311 SECTION 1509 ROOFTOP STRUCTURES
312 SECTION 1510 REROOFING
314 CHAPTER 16: STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS AND NOTATIONS
315 SECTION 1603 CONSTRUCTION DOCUMENTS
316 SECTION 1604 GENERAL DESIGN REQUIREMENTS
TABLE 1604.3 DEFLECTION LIMITS
318 TABLE 1604.5 OCCUPANCY CATEGORY OF BUILDINGS AND OTHER STRUCTURES
319 SECTION 1605 LOAD COMBINATIONS
EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
320 EQUATION 16-16
EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
EQUATION 16-21
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
321 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, ANDMINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, ANDMINIMUM CONCENTRATED LIVE LOADSg
322 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.6 UNIFORM AND CONCENTRATED LOADS
323 EQUATION 16-22
TABLE 1607.9.1 LIVE LOAD ELEMENT FACTOR
324 EQUATION 16-23
EQUATION 16-24
325 EQUATION 16-25
EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
326 SECTION 1608 SNOW LOADS
FIGURE 1608.2 GROUND SNOW LOADS
327 FIGURE 1608.2—continued GROUND SNOW LOADS
SECTION 1609 WIND LOADS
328 TABLE 1609.1.2 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS
329 FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST)
330 FIGURE 1609—continued BASIC WIND SPEED (3-SECOND GUST)
331 FIGURE 1609–continued BASIC WIND SPEED (3-SECOND GUST)WESTERN GULF OF MEXICO HURRICANE COASTLINE
332 FIGURE 1609–continued BASIC WIND SPEED (3-SECOND GUST)EASTERN GULF OF MEXICO AND SOUTHEASTERN U.S. HURRICANE COASTLINE
333 FIGURE 1609–continued BASIC WIND SPEED (3-SECOND GUST)MID AND NORTHERN ATLANTIC HURRICANE COASTLINE
334 EQUATION 16-32
TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEEDS
335 EQUATION 16-33
336 EQUATION 16-34
SECTION 1610 SOIL LATERAL LOADS
SECTION 1611 RAIN LOADS
337 EQUATION 16-35
SECTION 1612 FLOOD LOADS
TABLE 1609.6.2(1) WIND STAGNATION PRESSURE (qs) AT STANDARD HEIGHT OF 33 FEET
338 TABLE 1609.6.2(2) NET PRESSURE COEFFICIENTS
339 TABLE 1609.6.2(2)—continued NET PRESSURE COEFFICIENTS
340 TABLE 1609.6.2(2)—continued NET PRESSURE COEFFICIENTS
341 TABLE 1609.6.2(2)—continued NET PRESSURE COEFFICIENTS
342 TABLE 1609.6.2(2)—continued NET PRESSURE COEFFICIENTS
343 TABLE 1610.1 LATERAL SOIL LOAD
344 FIGURE 1611.1100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
345 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
346 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
347 SECTION 1613 EARTHQUAKE LOADS
348 EQUATION 16-36
EQUATION 16-37
EQUATION 16-38
EQUATION 16-39
349 TABLE 1613.5.2 SITE CLASS DEFINITIONS
TABLE 1613.5.3(1) VALUES OF SITE COEFFICIENT
TABLE 1613.5.3(2) VALUES OF SITE COEFFICIENT
350 EQUATION 16-40
EQUATION 16-41
EQUATION 16-42
EQUATION 16-43
TABLE 1613.5.5 SITE CLASSIFICATION
351 TABLE 1613.5.6(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD RESPONSE ACCELERATIONS
TABLE 1613.5.6(2) SEISMIC DESIGN CATEGORY BASED ON1-SECOND PERIOD RESPONSE ACCELERATION
352 EQUATION 16-44
EQUATION 16-45
353 SECTION 1614 STRUCTURAL INTEGRITY
354 EQUATION 16-46
EQUATION 16-47
355 FIGURE 1613.5(1) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
356 FIGURE 1613.5(1)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
357 FIGURE 1613.5(2) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
358 FIGURE 1613.5(2)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
359 FIGURE 1613.5(3) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS
360 FIGURE 1613.5(3)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
361 FIGURE 1613.5(4) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
362 FIGURE 1613.5(4)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
363 FIGURE 1613.5(5) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 2 OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
364 FIGURE 1613.5(6) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 2 OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
365 FIGURE 1613.5(7) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 3 OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% PERCENT OF CRITICAL DAMPING), SITE CLASS B
366 FIGURE 1613.5(8) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 3 OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
367 FIGURE 1613.5(9) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 4 OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
368 FIGURE 1613.5(10) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR HAWAII OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
369 FIGURE 1613.5(11) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR ALASKA OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
370 FIGURE 1613.5(12) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR ALASKA OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
371 FIGURE 1613.5(13) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR PUERTO RICO, CULEBRA, VIEQUES, ST. THOMAS,ST. JOHN AND ST. CROIX OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
372 FIGURE 1613.5(14) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR GUAM AND TUTUILLA OF0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
373 FIGURE 1614.4 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
374 CHAPTER 17: STRUCTURAL TESTS AND SPECIAL INSPECTIONS
SECTION 1701 GENERAL
SECTION 1702 DEFINITIONS
SECTION 1703 APPROVALS
375 SECTION 1704 SPECIAL INSPECTIONS
377 TABLE 1704.3 REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION
378 TABLE 1704.3—continued REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION
379 TABLE 1704.4 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
381 TABLE 1704.5.1 LEVEL 1 REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION
382 TABLE 1704.5.1—continued LEVEL 1 REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION
383 TABLE 1704.5.3 LEVEL 2 REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION
384 TABLE 1704.7 REQUIRED VERIFICATION AND INSPECTION OF SOILS
TABLE 1704.8 REQUIRED VERIFICATION AND INSPECTION OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1704.9 REQUIRED VERIFICATION AND INSPECTION OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
386 SECTION 1705 STATEMENT OF SPECIAL INSPECTIONS
388 SECTION 1706 SPECIAL INSPECTIONS FOR WIND REQUIREMENTS
SECTION 1707 SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE
389 SECTION 1708 STRUCTURAL TESTING FOR SEISMIC RESISTANCE
390 SECTION 1709 CONTRACTOR RESPONSIBILITY
SECTION 1710 STRUCTURAL OBSERVATIONS
SECTION 1711 DESIGN STRENGTHS OF MATERIALS
SECTION 1712 ALTERNATIVE TEST PROCEDURE
391 SECTION 1713 TEST SAFE LOAD
SECTION 1714 IN-SITU LOAD TESTS
SECTION 1715 PRECONSTRUCTION LOAD TESTS
392 SECTION 1716 MATERIAL AND TEST STANDARDS
394 CHAPTER 18: SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DEFINITIONS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
396 SECTION 1804 EXCAVATION, GRADING AND FILL
397 SECTION 1805 DAMPPROOFING AND WATERPROOFING
398 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
399 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
400 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLS
401 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLS
402 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHES
403 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES
404 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHES
405 EQUATION 18-1
EQUATION 18-2
EQUATION 18-3
SECTION 1808 FOUNDATIONS
407 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
408 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f C OF CONCRETE OR GROUT
TABLE 1808.8.2 MINIMUM CONCRETE COVER
SECTION 1809 SHALLOW FOUNDATIONS
409 TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLSOF LIGHT-FRAME CONSTRUCTION
410 SECTION 1810 DEEP FOUNDATIONS
413 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
414 EQUATION 18-4
417 EQUATION 18-5
EQUATION 18-6
EQUATION 18-7
EQUATION 18-8
EQUATION 18-9
EQUATION 18-10
418 EQUATION 18-11
424 CHAPTER 19: CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
SECTION 1904 DURABILITY REQUIREMENTS
425 TABLE 1904.3 MINIMUM SPECIFIED COMPRESSIVE STREN
FIGURE 1904.3 WEATHERING PROBABILITY MAP FOR CONCRETE
426 SECTION 1905 CONCRETE QUALITY, MIXING AND PLACING
427 SECTION 1906 FORMWORK, EMBEDDED PIPES AND CONSTRUCTION JOINTS
SECTION 1907 DETAILS OF REINFORCEMENT
SECTION 1908 MODIFICATIONS TO ACI 318
430 SECTION 1909 STRUCTURAL PLAIN CONCRETE
SECTION 1910 MINIMUM SLAB PROVISIONS
431 SECTION 1911 ANCHORAGE TO CONCRETE—ALLOWABLE STRESS DESIGN
EQUATION 19-1
TABLE 1911.2 ALLOWABLE SERVICE LOAD ON EMBEDDED BOLTS
SECTION 1912 ANCHORAGE TO CONCRETE—STRENGTH DESIGN
432 SECTION 1913 SHOTCRETE
433 SECTION 1914 REINFORCED GYPSUM CONCRETE
SECTION 1915 CONCRETE-FILLED PIPE COLUMNS
434 CHAPTER 20: ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
436 CHAPTER 21: MASONRY
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS AND NOTATIONS
439 SECTION 2103 MASONRY CONSTRUCTION MATERIALS
440 TABLE 2103.10 CERAMIC TILE MORTAR COMPOSITIONS
SECTION 2104 CONSTRUCTION
441 SECTION 2105 QUALITY ASSURANCE
TABLE 2105.2.2.1.1 COMPRESSIVE STRENGTH OF CLAY MASONRY
442 TABLE 2105.2.2.1.2 COMPRESSIVE STRENGTH OF CONCRETE MASONRY
SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
EQUATION 21-1
443 SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF MASONRY
TABLE 2109.2.1 ALLOWABLE STRESS GROSS CROSS-SECTIONAL AREA FOR DRY-STACKED, SURFACE-BONDED CONCRETE MASONRY WALLS
444 EQUATION 21-2
TABLE 2109.3.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
445 SECTION 2110 GLASS UNIT MASONRY
SECTION 2111 MASONRY FIREPLACES
447 FIGURE 2111.11 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
SECTION 2112 MASONRY HEATERS
448 SECTION 2113 MASONRY CHIMNEYS
450 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
451 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
452 FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
454 CHAPTER 22: STEEL
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
SECTION 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
455 SECTION 2206 STEEL JOISTS
456 SECTION 2207 STEEL CABLE STRUCTURES
SECTION 2208 STEEL STORAGE RACKS
SECTION 2209 COLD-FORMED STEEL
SECTION 2210 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
458 CHAPTER 23: WOOD
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
459 SECTION 2303 MINIMUM STANDARDS AND QUALITY
463 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
TABLE 2304.6 MINIMUM THICKNESS OF WALL SHEATHING
464 TABLE 2304.6.1 MAXIMUM BASIC WIND SPEED (mph) (3-SECOND GUST) PERMITTED FORWOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURESa
TABLE 2304.7(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHINGa
465 TABLE 2304.7(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
TABLE 2304.7(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING ANDSINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
466 TABLE 2304.7(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a, b(Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
TABLE 2304.7(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVERTWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS
469 TABLE 2304.9.1 FASTENING SCHEDULE
470 TABLE 2304.9.1—continued FASTENING SCHEDULE
471 TABLE 2304.9.1—continued FASTENING SCHEDULE
473 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL-FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP(Structural I
474 EQUATION 23-2
TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
475 SECTION 2306 ALLOWABLE STRESS DESIGN
TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
476 SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
477 TABLE 2306.2.1(1) ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGh
478 TABLE 2306.2.1(1)—continued ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURALPANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS FIR-LARCH,OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGh
479 TABLE 2306.2.1(2) ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMSUTILIZING MULTIPLE ROWS OF FASTENERS (HIGH LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb
480 TABLE 2306.2.1(2)—continued ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF FASTENERS (HIGH LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
481 TABLE 2306.3 ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
482 TABLE 2306.5 ALLOWABLE SHEAR FOR PARTICLE BOARD SHEAR WALL SHEATHINGb
TABLE 2306.6 ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION FOR TYPE V CONSTRUCTION ONLYa
483 TABLE 2306.7 ALLOWABLE SHEAR FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES
486 TABLE 2308.8(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
487 TABLE 2308.8(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
488 TABLE 2308.8(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
489 TABLE 2308.8(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
490 TABLE 2308.9.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS
492 FIGURE 2308.9.3 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
493 TABLE 2308.9.3(1) BRACED WALL PANELS
TABLE 2308.9.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.9.3(3) WOOD STRUCTURAL PANEL WALL SHEATHING
494 TABLE 2308.9.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING
TABLE 2308.9.3(5) HARDBOARD SIDING
495 FIGURE 2308.9.3.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING
497 TABLE 2308.9.5 HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS
498 TABLE 2308.9.5—continued HEADER AND GIRDER SPANSaFOR EXTERIOR BEARING WALLS
499 TABLE 2308.9.6 HEADER AND GIRDER SPANSa FOR INTERIOR BEARING WALLS
500 TABLE 2308.10.1 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS
501 TABLE 2308.10.2(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
502 TABLE 2308.10.2(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
503 TABLE 2308.10.2(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
504 TABLE 2308.10.2(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
505 TABLE 2308.10.3(1) RAFTER SPANS FOR COMMON LUMBER SPECIES
506 TABLE 2308.10.3(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
507 TABLE 2308.10.3(2) RAFTER SPANS FOR COMMON LUMBER SPECIES
508 TABLE 2308.10.3(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
509 TABLE 2308.10.3(3) RAFTER SPANS FOR COMMON LUMBER SPECIES
510 TABLE 2308.10.3(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
511 TABLE 2308.10.3(4) RAFTER SPANS FOR COMMON LUMBER SPECIES
512 TABLE 2308.10.3(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
513 TABLE 2308.10.3(5) RAFTER SPANS FOR COMMON LUMBER SPECIES
514 TABLE 2308.10.3(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
515 TABLE 2308.10.3(6) RAFTER SPANS FOR COMMON LUMBER SPECIES
516 TABLE 2308.10.3(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
517 TABLE 2308.10.4.1 RAFTER TIE CONNECTIONS
519 TABLE 2308.10.9 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
520 TABLE 2308.10.9–continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
521 FIGURE 2308.11.3.2 STEPPED FOOTING CONNECTION DETAILS
FIGURE 2308.11.3.3 OPENINGS IN HORIZONTAL DIAPHRAGMS
522 TABLE 2308.12.4 WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E
523 FIGURE 2308.12.6(1) BRACED WALL PANELS OUT OF PLANE
524 FIGURE 2308.12.6(2) BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK
FIGURE 2308.12.6(3) FLOOR OR ROOF NOT SUPPORTED ON ALL EDGES
FIGURE 2308.12.6(4) ROOF OR FLOOR EXTENSION BEYOND BRACED WALL LINE
525 FIGURE 2308.12.6(5) BRACED WALL PANEL EXTENSION OVER OPENING
FIGURE 2308.12.6(6) PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
FIGURE 2308.12.6(7) BRACED WALL LINES NOT PERPENDICULAR
526 FIGURE 2308.12.6(8) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
528 CHAPTER 24: GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMICAND DEAD LOADS ON GLASS
EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
529 EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
EQUATION 24-12
530 SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
531 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
532 TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
533 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
534 SECTION 2409 GLASS IN ELEVATOR HOISTWAYS AND ELEVATOR CARS
536 CHAPTER 25: GYPSUM BOARD AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
537 SECTION 2506 GYPSUM BOARD MATERIALS
TABLE 2506.2 GYPSUM BOARD MATERIALS AND ACCESSORIES
SECTION 2507 LATHING AND PLASTERING
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
538 TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 2509 GYPSUM BOARD IN SHOWERS AND WATER CLOSETS
539 SECTION 2510 LATHING AND FURRING FORCEMENT PLASTER (STUCCO)
SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
540 SECTION 2512 EXTERIOR PLASTER
TABLE 2512.6 CEMENT PLASTERSa
SECTION 2513 EXPOSED AGGREGATE PLASTER
542 CHAPTER 26: PLASTIC
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FOAM PLASTIC INSULATION
545 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
SECTION 2604 INTERIOR FINISH AND TRIM
546 SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
547 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
548 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELS
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
549 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
550 SECTION 2612 FIBER REINFORCED POLYMER AND FIBERGLASS REINFORCED POLYMER
551 SECTION 2613 REFLECTIVE PLASTIC CORE INSULATION
552 CHAPTER 27: ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
554 CHAPTER 28: MECHANICAL SYSTEMS
SECTION 2801 GENERAL
556 CHAPTER 29: PLUMBING SYSTEMS
SECTION 2901 GENERAL
558 CHAPTER 30: ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
SECTION 3002 HOISTWAY ENCLOSURES
SECTION 3003 EMERGENCY OPERATIONS
559 SECTION 3004 HOISTWAY VENTING
560 SECTION 3005 CONVEYING SYSTEMS
SECTION 3006 MACHINE ROOMS
SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
561 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
564 CHAPTER 31: SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
565 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
566 SECTION 3105 AWNINGS AND CANOPIES
567 SECTION 3106 MARQUEES
SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
SECTION 3109 SWIMMING POOL ENCLOSURES AND SAFETY DEVICES
568 SECTION 3110 AUTOMATIC VEHICULAR GATES
570 CHAPTER 32: ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
572 CHAPTER 33: SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
SECTION 3305 SANITARY
573 SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
574 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
575 SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
576 CHAPTER 34: EXISTING BUILDINGS AND STRUCTURES
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
577 SECTION 3403 ADDITIONS
SECTION 3404 ALTERATIONS
578 SECTION 3405 REPAIRS
579 SECTION 3406 FIRE ESCAPES
580 SECTION 3407 GLASS REPLACEMENT
SECTION 3408 CHANGE OF OCCUPANCY
SECTION 3409 HISTORIC BUILDINGS
SECTION 3410 MOVED STRUCTURES
SECTION 3411 ACCESSIBILITY FOR EXISTING BUILDINGS
581 TABLE 3411.8.5 RAMPS
582 SECTION 3412 COMPLIANCE ALTERNATIVES
584 EQUATION 34-1
EQUATION 34-2
EQUATION 34-3
EQUATION 34-4
TABLE 3412.6.3 COMPARTMENTATION VALUES
585 TABLE 3412.6.4 SEPARATION VALUES
TABLE 3412.6.5 CORRIDOR WALL VALUES
EQUATION 34-5
586 TABLE 3412.6.6(1) VERTICAL OPENING PROTECTION VALU
TABLE 3412.6.6(2) CONSTRUCTION-TYPE FACTOR
TABLE 3412.6.8 AUTOMATIC FIRE DETECTION VALUES
TABLE 3412.6.9 FIRE ALARM SYSTEM VALUES
587 TABLE 3412.6.10 SMOKE CONTROL VALUES
TABLE 3412.6.11(2) MEANS OF EGRESS VALUES
588 TABLE 3412.6.11(1) EGRESS WIDTH PER OCCUPANT SERVED
TABLE 3412.6.12 DEAD-END VALUES
EQUATION 34-6
TABLE 3412.6.15 MEANS OF EGRESS EMERGENCY LIGHTING VALUES
589 TABLE 3412.6.16 MIXED OCCUPANCY VALUESa
TABLE 3412.6.17 SPRINKLER SYSTEM VALUES
TABLE 3412.6.18 STANDPIPE SYSTEM VALUES
590 TABLE 3412.6.19 INCIDENTAL ACCESSORY OCCUPANCY VALUESa
TABLE 3412.8 MANDATORY SAFETY SCORESa
TABLE 3412.9 EVALUATION FORMULASa
591 TABLE 3412.7 SUMMARY SHEET — BUILDING CODE
592 CHAPTER 35: REFERENCED STANDARDS
AA
AAMA
ACI
593 AF&PA
AISC
AISI
AITC
594 ALI
ANSI
APA
595 APSP
ASABE
ASCE/SEI
596 ASME
ASTM
602 AWCI
AWPA
AWS
BHMA
CGSB
CPA
603 CPSC
CSA
CSSB
DASMA
DOC
604 DOJ
DOL
DOTn
EN
FEMA
605 FM
GA
HPVA
HUD
ICC
606 ISO
MI
NAAMM
607 NCMA
NFPA
608 PCI
PTI
RMI
SDI
609 SJI
SPRI
TIA
TMS
TPI
610 UL
611 ULC
USC
WDMA
WRI
612 APPENDIX F: RODENTPROOFING
SECTION F101 GENERAL
614 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
SECTION G102 APPLICABILITY
SECTION G103 POWERS AND DUTIES
615 SECTION G104 PERMITS
SECTION G105 VARIANCES
616 SECTION G201 DEFINITIONS
617 SECTION G301 SUBDIVISIONS
SECTION G401 SITE IMPROVEMENT
SECTION G501 MANUFACTURED HOMES
SECTION G601 RECREATIONAL VEHICLES
618 SECTION G701 TANKS
SECTION G801 OTHER BUILDING WORK
SECTION G901 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G1001 UTILITY AND MISCELLANEOUS GROUP U
619 SECTION G1101 REFERENCED STANDARDS
620 APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
621 SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
622 SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
623 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGN
TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS
624 INDEX
660 ICC MEMBERSHIP BENEFITS
661 ICC EVALUATION SERVICES
HELPFUL LINKS:
ICC WEBSITE
ICC PRODUCT STORE
ICC EVALUATION SERVICE – EVALUATION REPORTS OF PRODUCTS
MI BuildingCode 09 2009
$67.44