IEEE C62.50-2012
$60.67
IEEE Standard for Performance Criteria and Test Methods for Plug-in (Portable) Multiservice (Multiport) Surge-Protective Devices for Equipment Connected to a 120 V/240 V Single Phase Power Service and Metallic Conductive Communication Line(s)
Published By | Publication Date | Number of Pages |
IEEE | 2012 |
New IEEE Standard – Active. Test methods and performance criteria for plug-in (portable) multiservice (multiport) surge protective devices (MSPDs) intended to protect equipment connected to one or more metallic conductive telecommunication line(s) and a 120 V/240 V single phase two-wire (line and neutral) ac power service, with the neutral grounded at the service equipment are defined in this standard. Performance testing covers three areas: the ac power SPD section, the telecommunication SPD section, and the MSPD as whole. Essential MSPD performance characteristics are the reduction of surge current in the equipment ground loops and surge coupling between the individual SPD sections.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C62.50-2012 Front Cover |
3 | Title page |
6 | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata Patents |
8 | Participants |
10 | Introduction |
11 | Contents |
13 | Important notice 1. Overview 1.1 Scope |
14 | 1.2 Purpose 1.3 Contents and context 2. Normative references |
15 | 3. Definitions |
16 | 4. Markings 5. Surge environment and rationale for tests |
18 | 6. Test procedures for MSPD ac power port 6.1 General considerations 6.2 Initial characterization |
20 | 6.3 Power port ratings and characteristic values |
34 | 7. Test procedures and performance values for MSPD telecommunications service ports 7.1 General 7.2 Introduction and generic test approach |
41 | 7.3 Voltage limiting |
44 | 7.4 Current limiting |
49 | 7.5 Signal transmission parameters |
51 | 8. Test procedures and performance values for the MSPD protected-side inter-service and ground loop surge coupling 8.1 General 8.2 Impulse generator |
52 | 8.3 Verification of common grounding of individual service SPDs |
54 | 8.4 Test procedures and performance values for protected-side ground loop currents |
57 | 8.5 Test procedures and performance values for the coupled disturbances on the non-surged services |
60 | Annex A (informative) Peak surge current (Imax) |
61 | Annex B (informative) MSPD ac power service surge protective functions B.1 Introduction B.2 Voltage limiting B.3 Voltage switching B.4 Hybrid component B.5 Filtering |
63 | Annex C (informative) Bibliography |