Email:[email protected]

Revision Standard – Inactive – Superseded. This standard covers metal-enclosed interrupter (MEI) switchgear assemblies containing, but not limited to, such devices as interrupter switches; selector switches; power fuses; control, instrumentation and metering devices; and protective equipment. It includes, but is not specifically limited to, equipment for the control and protection of apparatus used for distribution of electrical power. Interpretations for this standard are available at: http://standards.ieee.org/reading/ieee/interp/C37.20Series.html

PDF Catalog

PDF Pages PDF Title
3 Introduction
4 Participants
7 Contents
9 1.Scope
2.References
11 3.De •nitions
12 3.1 Qualifying terms —switchgear
3.2 Qualifying terms —IEEE 100
3.3 Qualifying terms —IEEE Std C37.100-1992
13 3.4 Common or related terms
3.5 De •nitions of terms
14 4.Service conditions
15 5.Ratings
5.1 General
5.2 Voltag and insulation levels
5.3 Rated power frequency
16 5.4 Rated current
17 5.5 Temperature limitations
19 5.6 Current transformer ratings
6.Tests
6.1 General
20 6.2 Design tests
28 6.3 Production tests
29 6.4 Conformance test
30 7.Construction
7.1 Buses and primary connections
7.2 Grounding
31 7.3 Control and secondary circuits and devices
33 7.4 Miscellaneous
34 7.5 Materials and •nish
35 7.6 Precautionary labels
7.7 Barriers
7.8 Shutters
7.9 Interlocks
7.10 Enclosure categories
7.11 Indoor MEI switchgear,access,and ventilation
36 7.12 Outdoor MEI switchgear,access,and ventilation
8.Application guide for MEI switchgear
8.1 Unusual service conditions
39 8.2 System characteristics —voltag and frequency
8.3 Overvoltag considerations —insulation levels
8.4 Continuous current rating and overload capability
40 8.5 Short-circuit considerations
8.6 Nuclear power plant application
8.7 Exposed circuits
8.8 Surg arresters in switchgear assemblies
8.9 Protection and isolation of switchgear connected to other switching equipment
8.10 Current transformer accuracies
41 9.Guide for handling,storag ,and installation
9.1 Handling
43 9.2 Preoperation check
9.3 Interrupter switches
9.4 Interlocks
9.5 Energization
44 Annex A (informative) Guide for enclosure categories and related requirements