IEEE 11073-10406-2023
$49.83
IEEE Standard for Health Informatics–Device Interoperability Part 10406: Personal Health Device Communication–Device Specialization–Basic Electrocardiography (ECG) (1‐ to 3‐lead ECG) (Approved Draft)
Published By | Publication Date | Number of Pages |
IEEE | 2023 | 74 |
Revision Standard – Active. Within the context of the ISO/IEEE 11073 family of standards for device communication, a normative definition of the communication between personal basic electrocardiograph (ECG) devices and managers (e.g., cell phones, personal computers, personal health appliances, and set-top boxes) in a manner that enables plug-and-play interoperability is established in this standard. Appropriate portions of existing standards including ISO/IEEE 11073 terminology and IEEE 11073-20601 information models are leveraged. The use of specific term codes, formats, and behaviors in telehealth environments restricting optionality in base frameworks in favor of interoperability is specified. A common core of communication functionality for personal telehealth basic ECG (1- to 3-lead ECG) devices is defined. Monitoring ECG devices are distinguished from diagnostic ECG equipment with respect to including support for wearable ECG devices, limiting the number of leads supported by the equipment to three, and not requiring the capability of annotating or analyzing the detected electrical activity to determine known cardiac phenomena. This standard is consistent with the base framework and allows multifunction implementations by following multiple device specializations (e.g., ECG and respiration rate).
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 11073-10406™-2023 Front cover |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
8 | Introduction |
9 | Participants |
12 | Contents |
14 | 1. Overview 1.1 Scope 1.2 Purpose |
15 | 1.3 Context 1.4 Word usage 2. Normative references |
16 | 3. Definitions, acronyms, and abbreviations 3.1 Definitions |
17 | 3.2 Acronyms and abbreviations 4. Introduction to ISO/IEEE 11073 personal health devices 4.1 General |
18 | 4.2 Introduction to ISO/IEEE 11073-20601 modeling constructs 4.2.1 General 4.2.2 Domain information model 4.2.3 Service model 4.2.4 Communication model 4.2.5 Implementing the models 4.3 Compliance with other standards |
19 | 5. Basic ECG (1- to 3-lead ECG) device concepts and modalities 5.1 General 5.2 ECG waveform 5.3 R-R interval 5.4 Heart rate |
20 | 6. Basic ECG (1- to 3-lead ECG) domain information model 6.1 Overview 6.2 Class extensions 6.3 Object instance diagram |
21 | 6.4 Types of configuration 6.4.1 General |
22 | 6.4.2 Standard configuration 6.4.3 Extended configuration 6.5 Profiles 6.5.1 General 6.5.2 Simple ECG profile 6.5.3 Heart rate profile |
24 | 6.6 Medical device system object 6.6.1 MDS object attributes |
25 | 6.6.2 Tick-Resolution attribute 6.6.3 MDS object methods |
26 | 6.6.4 MDS object events |
27 | 6.6.5 Other MDS services 6.6.5.1 GET service |
28 | 6.6.5.2 SET service 6.7 Numeric objects 6.7.1 General 6.7.2 Heart rate |
31 | 6.7.3 R-R interval 6.8 Real-time sample array objects 6.8.1 General |
32 | 6.8.2 ECG waveform |
33 | 6.9 Enumeration objects 6.9.1 General 6.9.2 Device status |
34 | 6.9.3 Context Data Trigger |
35 | 6.10 PM-store objects 6.10.1 General |
36 | 6.10.2 Persistent store model |
37 | 6.10.3 Periodic |
38 | 6.10.4 Aperiodic |
39 | 6.10.5 PM-store object methods 6.10.6 PM-store object events |
40 | 6.10.7 PM-store object services 6.10.7.1 General 6.10.7.2 GET service 6.10.7.3 SET service 6.10.8 PM-segment objects 6.10.8.1 Periodic session |
41 | 6.10.8.2 Aperiodic session |
42 | 6.11 Scanner objects 6.11.1 General |
43 | 6.11.2 Periodic configurable scanner attributes |
44 | 6.11.3 Episodic configurable scanner attributes 6.12 Class extension objects |
45 | 6.13 Basic ECG (1- to 3-lead ECG) information model extensibility rules 7. Basic ECG (1- to 3-lead ECG) service model 7.1 General 7.2 Object access services |
48 | 7.3 Object access event report services 8. Basic ECG (1- to 3-lead ECG) communication model 8.1 Overview 8.2 Communications characteristics |
49 | 8.3 Association procedure 8.3.1 General 8.3.2 Agent procedure—association request |
50 | 8.3.3 Manager procedure—association response |
51 | 8.4 Configuring procedure 8.4.1 General 8.4.2 Basic ECG (1- to 3-lead ECG)—standard configuration 8.4.2.1 Agent procedure |
52 | 8.4.2.2 Manager procedure 8.5 Operating procedure 8.5.1 General 8.5.2 GET basic ECG (1- to 3-lead ECG) MDS attributes 8.5.3 Measurement data transmission |
53 | 8.6 Time synchronization 9. Test associations 9.1 Behavior with standard configuration 9.2 Behavior with extended configurations 10. Conformance 10.1 Applicability |
54 | 10.2 Conformance specification 10.3 Levels of conformance 10.3.1 General 10.3.2 Conformance level 1: Base conformance 10.3.3 Conformance level 2: Extended nomenclature (ASN.1 and/or ISO/IEEE 11073-10101) 10.4 Implementation conformance statements (ICSs) 10.4.1 General format |
55 | 10.4.2 General ICS |
56 | 10.4.3 DIM MOC ICS |
57 | 10.4.4 MOC attribute ICS |
58 | 10.4.5 MOC notification ICS 10.4.6 MOC nomenclature ICS |
59 | Annex A (informative) Bibliography |
60 | Annex B (normative) Any additional ASN.1 definitions B.1 Bit mappings for device, lead, and signal status |
61 | Annex C (normative) Allocation of identifiers |
62 | Annex D (informative) Message sequence examples |
64 | Annex E (informative) Protocol data unit examples E.1 General E.2 Association information exchange E.2.1 General E.2.2 Extended configuration E.2.2.1 General E.2.2.2 Association request |
65 | E.2.2.1 Association response E.2.3 Previously known extended configuration E.2.3.1 General E.2.3.2 Association request |
66 | E.2.3.3 Association response E.2.4 Standard configuration E.2.4.1 General E.2.4.2 Association request |
67 | E.2.4.3 Association response E.3 Configuration information exchange E.3.1 General |
68 | E.3.2 Extended configuration E.3.2.1 General E.3.2.2 Remote operation invoke event report configuration |
69 | E.3.2.3 Remote operation response event report configuration E.3.3 Known configuration E.3.3.1 General E.3.3.2 Remote operation invoke event report configuration E.3.3.3 Remote operation response event report configuration |
70 | E.3.4 Standard configuration E.3.4.1 General E.3.4.2 Remote operation invoke event report configuration E.3.4.3 Remote operation response event report configuration E.4 GET MDS attributes service E.4.1 General E.4.2 Get all MDS attributes request E.4.3 Get response with all MDS attributes |
72 | E.5 Data reporting E.5.1 Unconfirmed measurement data transmission E.6 Disassociation E.6.1 Association release request E.6.2 Association release response |
73 | Annex F (informative) Revision history |