Shopping Cart

No products in the cart.

IEC 60754-3:2018

$43.55

Test on gases evolved during combustion of materials from cables – Part 3: Measurement of low level of halogen content by ion chromatography

Published By Publication Date Number of Pages
IEC 2018-03-19 50
Guaranteed Safe Checkout
Categories: , ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60754-3:2018 specifies the apparatus and procedure for the measurement of the amount of halogens evolved during the combustion of materials taken from electric or optical fibre cable constructions.
The method specified in this document is intended for the measurement of the content of chlorine (Cl), bromine (Br), fluorine (F) and iodine (I), by using the analytical technique of ion chromatography for analysing an aqueous solution resulting from the gases evolved during the combustion.
The heating (combustion) procedure in this part of IEC 60754 is the same as in IEC 60754-2.
The method is intended for materials with an individual halogen content not exceeding 10 mg/g.
The method specified in this document is intended for the testing of individual components used in a cable construction. The use of this method will enable the verification of requirements which are stated in the appropriate cable specification for individual components of a cable construction.
For reasons of precision, this method is not recommended for detecting values of halogens less than 0,1 mg/g of the sample taken.

IEC 60754-3:2018
$43.55