Shopping Cart

No products in the cart.

FL Energy 07 2007

$12.32

Florida Building Code – Energy

Published By Publication Date Number of Pages
FL 2007 228
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Energy Code is Chapter 13 of the Florida Building Code

PDF Catalog

PDF Pages PDF Title
1 2007 FLORIDA BUILDING CODE – CHAPTER 13: FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION
3 CHAPTER 13: ENERGY EFFICIENCY
SUBCHAPTER 13-1 – ADMINISTRATION AND ENFORCEMENT
SECTION 13-100: GENERAL
SECTION 13-101: SCOPE
6 SECTION 13-102: MATERIAL AND EQUIPMENT
SECTION 103: CODE COMPLIANCE AND PERMITTING
7 SECTION 13-104: INSPECTIONS
8 SECTION 13-105: REPORTING
TABLE 13-105.1: REPORTING SCHEDULE
SECTION 13-106: VALIDITY
9 FIGURE 1-1: CODE COMPLIANCE CHART
11 SUBCHAPTER 13-2 – DEFINITIONS
SECTION 13-201 – GENERAL
SECTION 13-202 – DEFINITIONS
27 SUBCHAPTER 13-3 – REFERENCED STANDARDS AND ORGANIZATIONS
SECTION 13-301: REFERENCED STANDARDS
AABC
AAMA
ACCA
ADC
28 AHAM
AMCA
ANSI
ARDM
ARI
29 ASHRAE
ASTM
30 CRRC
CTI
DASMA
DOE
31 FLORIDA CODES
FSEC
FTC
GAMA
32 HI
HUD
ISO
NAIMA
NEBB
33 NEMA
NFPA
NFRC
SMACNA
SRCC
UL
34 WDMA
35 SUBCHAPTER 13-4 – COMMERCIAL BUILDING COMPLIANCE METHODS
SECTION 13-400: ADMINISTRATION
37 TABLE 13-400.ABC.3: INDEX TO COMMERCIAL CODE COMPLIANCE FORMS
SECTION 13-401: FENESTRATIONS (Glazing)
38 TABLE 13-401.C.3: SHGC Multipliers for Permanent Projections
SECTION 13-402: WALLS
SECTION 13-403: DOORS
39 SECTION 13-404: ROOFS/CEILINGS
TABLE 13-404.C.1: ROOF U-FACTOR MULTIPLIERS FOR EXCEPTION TO 13-404.C.1
SECTION 13-405: FLOORS
SECTION 13-406: AIR INFILTRATION
40 SECTION 13-407: SPACE COOLING SYSTEMS
45 SECTION 13-408: SPACE HEATING EQUIPMENT
46 TABLE 13-407.3.2.1A: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS.
47 TABLE 13-407.ABC.3.2.1B: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS – MINIMUM EFFICIENCY REQUIREMENTS
48 TABLE 13-407.ABC.3.2.1C – WATER CHILLING PACKAGES MINIMUM EFFICIENCY REQUIREMENTS
49 TABLE 13-407.ABC.3.2.1D – ELECTRICALLY-OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICLE AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR CONDITIONER HEAT PUMPS – MINIMUM EFFICIENCY REQUIREMENTS
50 TABLE 13-407.ABC.3.2.1G – PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT
51 TABLE 13-407.ABC.3.2.2H – MINIMUM EFFICIENCIES FOR CENTRIFUGAL CHILLERS <150 TONS COP = 5.00; IPLV = 5.25
52 TABLE 13-407.ABC.3.2.2I – MINIMUM EFFICIENCIES FOR CENTRIFUGAL CHILLERS >150 TONS, <300 TONS COP = 5.55; IPLV = 5.90
53 TABLE 13-407.ABC.3.2.2J – MINIMUM EFFICIENCIES FOR CENTRIFUGAL CHILLERS >300 TONS COP = 6.10; IPLV = 6.40
54 TABLE 13-408.ABC.3.2.1E – WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS. MINIMUM EFFICIENCY REQUIREMENTS
SECTION 13-409: VENTILATION
55 TABLE 13-408.ABC.3.2.1F – GAS- AND OIL-FIRED BOILERS MINIMUM EFFICIENCY REQUIREMENTS
TABLE 13-409.ABC.3.3.1 – MAXIMUM DAMPER LEAKAGE
56 SECTION 13-410 – AIR DISTRIBUTION SYSTEMS
TABLE 13-410.ABC.1.1.1 – FAN POWER LIMITATION
57 TABLE 13-410.ABC.2.2 – MINIMUM DUCT INSULATION R-VALUES Combined Heating and Cooling Supplu and Return Ducts
62 SECTION 13-411 – PUMPS AND PIPING
63 SECTION 13-412 – WATER HEATING SYSTEMS
64 TABLE 13-411.ABC.2 – MINIMUM PIPE INSULATION (inches)
65 SECTION 13-413 – ELECTRIC POWER
SECTION 13-414 – MOTORS
SECTION 13-415 – LIGHTING
66 TABLE 13-412.ABC.3 – PERFORMANCE REQUIREMENTS FOR WATER HEATING EQUIPMENT
67 TABLE 13-414.ABC.1 – MINIMUM NOMINAL EFFICIENCY FOR GENERAL PURPOSE Design A and Design B Motors
69 TABLE 13-415.ABC.2.2 – LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS
71 TABLE 13-415.B.1 – LIGHTING POWER DENSITIES (LPD) USING THE SPACE-BY-SPACE METHOD
72 TABLE 13-415.C.1 – LIGHTING POWER DENSITIES USING THE BUILDING AREA METHOD
73 SUBCHAPTER 13-6 – RESIDENTIAL BUILDING COMPLIANCE METHODS
SECTION 13-600 – ADMINISTRATION
75 SECTION 13-601 – FENESTRATIONS (GLAZING)
76 SECTION 13-602 – WALLS
77 SECTION 13-603 – DOORS
SECTION 13-604 – CEILINGS
78 SECTION 13-605 – FLOORS
79 FIGURE 13-604.A.3: ACCEPTABLE ATTIC RADIANT BARRIER CONFIGURATIONS
80 SECTION 13-606 – AIR INFILTRATION
TABLE 13-606.ABC.1.1 – ALLOWABLE AIR INFILTRATION RATES
81 SECTION 13-607 – SPACE COOLING SYSTEMS
84 TABLE 13-607.ABC.3.2A – ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS – MINIMUM EFFICIENCY REQUIREMENTS
85 TABLE 13-607.ABC.3.2B – ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS – MINIMUM EFFICIENCY REQUIREMENTS
86 TABLE 13-607.ABC.3.2D – ELECTRICALLY OPERATRED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOOM AIR CONDITIONERS HEAT PUMPS – MINIMUM EFFICIENCY REQUIREMENTS
88 SECTION 13-608 – SPACE HEATING SYSTEMS
89 TABLE 13-608.ABC.3.2E- WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS. MINIMUM EFFICIENCY REQUIREMENTS
90 TABLE 13-608.ABC.3.2FGAS- AND OIL-FIRED BOILERS MINIMUM EFFICIENCY REQUIREMENTS
SECTION 13-609 – VENTILATION SYSTEMS
91 SECTION 13-610 – AIR DISTRIBUTION SYSTEMS
TABLE 13-610.ABC.2.1 – MINIMUM INSULATION LEVELS AIR DISTRIBUTION SYSTEM COMPONENTS1
96 SECTION 13-611 – PIPING
TABLE 13-611.ABC.1 – MINIMUM PIPE INSULATION
97 SECTION 13-612 – WATER HEATING SYSTEMS
98 TABLE 13-612.ABC.3 – MINIMUM PERFORMANCE STANDARDS WATER HEATING EQUIPMENT: FIRED STORAGE WATER HEATER MINIMUM ENERGY FACTORS (EF)
99 SECTION 13-613 – CALCULATIONAL PARAMETERS SPECIFIC TO COMPLIANCE METHOD A
TABLE 13-613.A.1-1 – SPECIFICATIONS FOR BASELINE AND AS-BUILT HOMES
101 TABLE 13-613.A.1-1(a) – DEFAULT BASELINE HOME HEATING AND COOLING EQUIPMENT EFFICIENCIES (i) (k) (m) (n)
102 TABLE 13-613.A.2-1 – COEFFICIENTS a and b
103 APPENDIX 13-A – JURISDICTIONAL DATA
ALACHUA COUNTY
BAKER COUNTY
BAY COUNTY
BRADFORD COUNTY
BREVARD COUNTY
104 BROWARD COUNTY
CALHOUN COUNTY
CHARLOTTE COUNTY
CITRUS COUNTY
CLAY COUNTY
105 COLLIER COUNTY
COLUMBIA COUNTY
DESOTO COUNTY
DIXIE COUNTY
DUVAL COUNTY
ESCAMBIA COUNTY
FLAGLER COUNTY
FRANKLIN COUNTY
GADSDEN COUNTY
106 GILCHRIST COUNTY
GLADES COUNTY
GULF COUNTY
HAMILTON COUNTY
HARDEE COUNTY
HENDRY COUNTY
HERNANDO COUNTY
HIGHLANDS COUNTY
HILLSBOROUGH COUNTY
HOLMES COUNTY
INDIAN RIVER COUNTY
107 JACKSON COUNTY
JEFFERSON COUNTY
LAFAYETTE COUNTY
LAKE COUNTY
LEE COUNTY
LEON COUNTY
LEVY COUNTY
LIBERTY COUNTY
108 MADISON COUNTY
MANATEE COUNTY
MARION COUNTY
MARTIN COUNTY
MIAMI-DADE COUNTY
109 MONROE COUNTY
NASSAU COUNTY
OKALOOSA COUNTY
OKEECHOOBEE COUNTY
ORANGE COUNTY
110 OSCEOLA COUNTY
PALM BEACH COUNTY
111 PASCO COUNTY
PINELLAS COUNTY
112 POLK COUNTY
PUTNAM COUNTY
ST JOHNS COUNTY
ST LUCIE COUNTY
SANTA ROSA COUNTY
SARASOTA COUNTY
SEMINOLE COUNTY
113 SEMINOLE INDIAN TRIBE
SUMTER COUNTY
SUWANNEE COUNTY
TAYLOR COUNTY
UNION COUNTY
VOLUSIA COUNTY
WAKULLA COUNTY
WALTON COUNTY
114 WASHINGTON COUNTY
115 APPENDIX 13-B – SUPPLEMENTAL INFORMATION FOR SUBCHAPTER 13-4
B1.0 GENERAL REQUIREMENTS
117 B2.0 BUILDING ENVELOPE CHARACTERISTICS
118 TABLE B-1 – EMITTANCE VALUES OF VARIOUS SURFACES AND EFFECTIVE EMITTANCES OF AIR SPACES
TABLE B-2 – R-VALUES FOR CAVITY AIR SPACES
TABLE B-3 – EFFECTIVE R-VALUES FOR FIBERGLASS
119 TABLE B-4 – R-VALUES FOR BUILDING MATERIALS
TABLE B-5 – THERMAL CONDUCTIVITY OF CONCRETE BLOCK MATERIAL
120 TABLE B-6 – ASSEMBLY U-FACTORS FOR UNLABELED SKYLIGHTS
121 TABLE B-7 – ASSEMBLY SOLAR HEAT GAIN COEFFICIENTS (SHGC) AND ASSEMBLY VISIBLE LIGHT TRANSMITTANCES (VLT)FOR UNLABELED SKYLIGHTS
122 TABLE B-8 – ASSEMBLY U-FACTORS, ASSEMBLY SOLAR HEAT GAIN COEFFICIENTS (SHGC), AND ASSEMBLY VISIBLE LIGHTTRANSMITTANCES (VLT) FOR UNLABELED VERTICAL FENESTRATION
123 TABLE B-9 – ASSEMBLY U-FACTORS FOR ABOVE-GRADE CONCRETE WALLS AND MASONRY WALLS
125 TABLE B-10 – ASSEMBLY U-FACTORS, C-FACTORS, Ru, Rc, AND HEAT CAPACITY FOR CONCRETE
127 TABLE B-11 – ASSEMBLY U-FACTORS, C-FACTORS, RU, RC, AND HEAT CAPACITY FOR CONCRETE BLOCK WALLS
130 TABLE B-12 – EFFECTIVE R-VALUES FOR INSULATION/FRAMING LAYERS ADDED TO ABOVE-GRADE MASS WALLS AND BELOW-GRADE WALLS
131 TABLE B-13 – ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS
TABLE B-14 – ASSEMBLY U-FACTORS FOR STEEL FRAME WALLS
133 TABLE B-15 – ASSEMBLY U-FACTORS FOR WOOD FRAME WALLS
134 TABLE B-16 – ASSEMBLY C-FACTORS FOR BELOW-GRADE WALLS
TABLE B-17 – EFFECTIVE INSULATION/FRAMING LAYER R-VALUES FORWALL INSULATION INSTALLED BETWEEN STEEL FRAMING
135 TABLE B-18 – EFFECTIVE INSULATION/FRAMING LAYER R-VALUES FOR ROOF AND FLOOR INSULATION INSTALLED BETWEEN METALFRAMING (4 FT ON CENTER)
TABLE B-19 – ASSEMBLY U-FACTORS FOR ROOFS WITH INSULATION ENTIRELY ABOVE DECK
137 TABLE B-20 – ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS
138 TABLE B-21 – BASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH WOOD JOISTS
TABLE B-22 – ASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH STEEL JOISTS (4.0 FT ON CENTER)
TABLE B-21A – Single Rafter Roofs
140 TABLE B-23 – ASSEMBLY U-FACTORS FOR MASS FLOORS
141 TABLE B-24 – ASSEMBLY U-FACTORS FOR STEEL JOIST FLOORS
142 TABLE B-25 – ASSEMBLY U-FACTORS FOR WOOD JOIST FLOORS
143 B3.1 CALCULATION PROCEDURES
B4.1 LIGHTING CALCULATION PROCEDURES
144 TABLE B-26 – ASSEMBLY F-FACTORS FOR SLAB-ON-GRADE FLOORS
145 APPENDIX 13-C – SUPPLEMENTAL INFORMATION FOR SUBCHAPTER 13-6
13-C1.0 – GENERAL REQUIREMENTS
TABLE 13-C1.2.2 – R-VALUES OF COMPRESSED INSULATION
TABLE 13-C1.2.3 – INSULATION INSTALLATION STANDARDS
13-C2.0 GENERAL CRITERIA FOR THE BUILDING ENVELOPE
146 TABLE 13-C2.1.1 – DEFAULT WINDOW ENERGY VALUES FOR RESIDENTIAL APPLICATIONS
13-C3.0 -INFILTRATION AND INTERNAL GAINS
147 13-C4.0 – HEATING, VENTILATING AND AIR CONDITIONING
148 TABLE 13-C4.1.1A – COOLING SYSTEM ASSUMED, MINIMUM RATINGS BY DATE PERMITTED AIR CONDITIONERS
TABLE 13-C4.1.1B – HEATING SYSTEM ASSUMED, MINIMUM RATINGS BY DATE PERMITTED HEAT PUMPS
149 SUB-APPENDIX 13-2C – SUPPLEMENTAL CRITERIA FOR THE ALTERNATE RESIDENTIAL POINTS SYSTEM METHOD
13-2C1.0 – GENERAL REQUIREMENTS
(EQUATION 13-2C1.2)
13-C2.0 – BUILDING ENVELOPE PERORMANCE CRITERIA
(EQUATION 13-2C2.1.2A)
(EQUATION 13-2C2.1.2B)
(EQUATION 13-2C2.1.2C)
(EQUATION 13-2C2.1.2D)
150 (EQUATION 13-2C2.1.2E)
(EQUATION 13-2C2.1.2F)
(EQUATION 13-2C2.1.2G)
(EQUATION13-2C2.1.2H)
FIGURE 6.1
151 TABLE 13-2C2.1.1A – SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENTAND ORIENTATION FOR CLIMATE ZONES 1, 2, 3
153 TABLE 13-2C2.1.1B – SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENTAND ORIENTATION FOR CLIMATE ZONES 4,5,6
155 TABLE 13-2C2.1.1C – SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENTAND ORIENTATION FOR CLIMATE ZONES 7,8,9
157 TABLE 13-2C2.2.2 – CONCRETE BLOCK MULTIPLIERS POLYSTYRENE BEAD AGGREGATE
TABLE 13-2C2.4.1 – CEILING UNDER ATTIC SUMMER AND WINTER POINT MULTIPLIERS
158 TABLE 13-2C2.4.2 – CEILING SINGLE ASSEMBLY SUMMER AND WINTER POINT MULTIPLIERS
TABLE 13-2C2.4.3 – CONCRETE DECK ROOF: EXPOSED SUMMER AND WINTER POINT MULTIPLIERS
13-2C3.0 – Infiltration and internal gains.
13-2C4.0 – Heating, ventilating and air conditioning.
(Equation 13-2C4.1.1)
159 TABLE 13-2C2.4.4 – CONCRETE ROOF DECK: DROPPED SUMMER AND WINTER POINT MULTIPLIERS
TABLE 13-2C2.5.1 – FLOORS MULTIPLIERS FOR STEM WALL WITH STEM WALL INSULATION
TABLE 13-2C4.1.2A – COOLING SYSTEM MULTIPLIER ASSUMED MINIMUM RATINGS BY DATE PERMITTED AIR CONDITIONERS
160 TABLE 13-2C4.1.2B – HEATING SYSTEM MULTIPLIER ASSUMED MINIMUM RATINGS BY DATE PERMITTED HEAT PUMPS
TABLE 13-2C4.2.1.1 – FAN SIZING TABLE
TABLE 13-2C4.2 – COOLING SYSTEM MULTIPLIERS GAS FUELED AIR CONDITIONERS
162 FIGURE 13-2C4.2.1.4 – ACCEPTABLE ATTIC RADIANT BARRIER CONFIGURATIONS
163 TABLE 13-2C4.3.1.3A – HEATING SYSTEM CREDIT MULTIPLIERS FOR COMBINED HYDRONIC SPACE GAS WATER HEATING WITH A STORAGE TANK
TABLE 13-2C4.3.1.3B – HEATING SYSTEM CREDIT MULTIPLIERS FOR COMBINED HYDRONIC INSTANTANEOUS (TANKLESS) GAS WATER HEATING
164 TABLE 13-2C4.3.2.1 – HEATING SYSTEM MULTIPLIERS GAS FUELED HEAT PUMPS
13-2C5.0 – Air distribution systems.
165 TABLE 13-2C5.2.1A – DUCT MULTIPLIERS NORTH FLORIDA
167 TABLE 13-2C5.2.1B – DUCT MULTIPLIERS CENTRAL FLORIDA
169 TABLE 13-2C5.2.1C – DUCT MULTIPLIERS SOUTH FLORIDA
171 13-2C6.0 – Service hot water.
TABLE 13-2C6.2.1 – GAS INSTANTANEOUS (TANKLESS) WATER HEATER MULTIPLIERS
173 APPENDIX 13-D
175 Form 400C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION SUBCHAPTER 4 – Commercial Building Compliance Methods – ASHRAE CLIMATE ZONE 2
177 Form 400C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTIONSUBCHAPTER 4 – Commercial Building Compliance Methods – ASHRAE CLIMATE ZONE 1
179 FORM 600A-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION – Alternate Residential Points System Method – NORTH 1 2 3
180 SUMMER CALCULATIONS CLIMATE ZONES 1 2 3
181 SUMMER POINT MULTIPLIERS (SPM) CLIMATE ZONES 1 2 3
182 WINTER CALCULATIONS CLIMATE ZONES 1 2 3
183 WINTER POINT MULTIPLIERS (WPM) CLIMATE ZONES 1 2 3
184 ADDITIONAL TABLES CLIMATE ZONES 1 2 3
185 FORM 600A-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Alternate Residential Points System Method CENTRAL 4 5 6
186 SUMMER CALCULATIONS CLIMATE ZONES 4 5 6
187 SUMMER POINT MULTIPLIERS (SPM) CLIMATE ZONES 4 5 6
188 WINTER CALCULATIONS CLIMATE ZONES 4 5 6
189 WINTER POINT MULTIPLIERS (WPM) CLIMATE ZONES 4 5 6
190 ADDITIONAL TABLES CLIMATE ZONES 4 5 6
191 FORM 600A-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Alternate Residential Points System Method SOUTH 7 8 9
192 SUMMER CALCULATIONS CLIMATE ZONES 7 8 9
193 SUMMER POINT MULTIPLIERS (SPM) CLIMATE ZONES 7 8 9
194 WINTER CALCULATIONS CLIMATE ZONES 7 8 9
195 WINTER POINT MULTIPLIERS (WPM) CLIMATE ZONES 7 8 9
196 ADDITIONAL TABLES CLIMATE ZONES 7 8 9
197 FORM 1100B-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Component Prescriptive Method B NORTH 1 2 3
198 TABLE 11B-1 MINIMUM REQUIREMENTS Climate Zones 1 2 3
199 FORM 1100B-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Component Prescriptive Method B CENTRAL 4 5 6
200 TABLE 11B-1 MINIMUM REQUIREMENTS Climate Zones 4 5 6
201 FORM 1100B-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Component Prescriptive Method B SOUTH 7 8 9
202 TABLE 11B-1 MINIMUM REQUIREMENTS Climate Zones 7 8 9
203 FORM 1100C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Limited Applications Prescriptive Method C NORTH 1 2 3
205 FORM 1100C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Limited Applications Prescriptive Method C CENTRAL 4 5 6
207 FORM 1100C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Limited Applications Prescriptive Method C SOUTH 7 8 9
209 FORM 1100D-07 – DESUPERHEATER, HEAT RECOVERY UNIT (HRU) WATER HEATER EFFICIENCY CERTIFICATION
210 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
211 APPENDIX 13-E – FLORIDA STANDARD NO. 1 (FL-1) FLORIDA REGULATORY MODIFICATIONS TO AIR-CONDITIONING & REFRIGERATION INSTITUTE (ARI) STANDARD 470-80 Effective April 1, 1986
SECTION 1 – PURPOSE
SECTION 2 – SCOPE
SECTION 3 – DEFINITIONS
SECTION 4 – STANDARD EQUIPMENT AND ACCESSORIES
SECTION 5 – TESTING AND RATING REQUIREMENTS
212 SECTION 7 – MARKING
SECTION 8 – CONFORMANCE
SECTION A2 – SCOPE
SECTION A3 – DEFINITIONS
SECTION A4 – EXPRESSION OF TEST RESULTS
SECTION A5 – TEST METHODS
213 2007 FLORIDA BUILDING CODE CHAPTER 1 BUILDING
215 CHAPTER 1 ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
217 SECTION 103 DEPARTMENT OF BUILDING SAFETY RESERVED
SECTION 104 DUTIES AND POWERS OF THE BUILDING OFFICIAL
SECTION 105 PERMITS
221 SECTION 106 CONSTRUCTION DOCUMENTS
224 SECTION 107 TEMPORARY STRUCTURES AND USES
SECTION 108 FEES
225 SECTION 109 INSPECTIONS
227 SECTION 110 CERTIFICATES OF OCCUPANCY AND COMPLETION
228 SECTION 111 SERVICE UTILITIES
SECTION 112 BOARD OF APPEALS RESERVED
SECTION 113 VIOLATIONS RESERVED
SECTION 114 STOP WORK ORDER
SECTION 115 UNSAFE STRUCTURES AND EQUIPMENT RESERVED
FL Energy 07 2007
$12.32