Measurement of fluid flow by means of pressure-differential devices. Guidelines for the specification of orifice plates, nozzles and Venturi tubes beyond the scope of ISO 5167

Published By Publication Date Number of Pages
BSI 2018 38
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document describes the geometry and method of use for conical-entrance orifice plates, quarter-circle orifice plates, eccentric orifice plates and Venturi tubes with 10,5° convergent angles. Recommendations are also given for square-edged orifice plates and nozzles under conditions outside the scope of ISO 5167.

NOTE The data on which this document is based are limited in some cases.

PDF Catalog

PDF Pages PDF Title
2 National foreword
6 Foreword
7 1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
9 5 Square-edged orifice plates and nozzles: With drain holes, in pipes below 50 mm diameter, and as inlet and outlet devices
5.1 Drain holes through the upstream face of the square-edged orifice plate or nozzle
5.1.1 General
5.1.2 Square-edged orifice plates
11 5.1.3 ISA 1932 nozzles
5.1.4 Long radius nozzles
5.2 Square-edged orifice plates installed in pipes of diameter 25 mm ≤ D < 50 mm
5.2.1 General
5.2.2 Limits of use
12 5.2.3 Discharge coefficients and corresponding uncertainties
5.3 No upstream or downstream pipeline
5.3.1 General
5.3.2 Flow from a large space (no upstream pipeline) into a pipeline or another large space
14 5.3.3 Flow into a large space (no downstream pipeline)
15 6 Orifice plates (except square-edged)
6.1 Conical entrance orifice plates
6.1.1 General
6.1.2 Limits of use
16 6.1.3 Description
19 6.1.4 Pressure tappings
20 6.1.5 Coefficients and corresponding uncertainties
6.2 Quarter-circle orifice plates
6.2.1 General
6.2.2 Limits of use
21 6.2.3 Description
24 6.2.4 Pressure tappings
6.2.5 Coefficients and corresponding uncertainties
25 6.3 Eccentric orifice plates
6.3.1 General
26 6.3.2 Limits of use
6.3.3 Description
29 6.3.4 Coefficients and corresponding uncertainties
31 7 Venturi tubes with machined convergent of angle 10,5°
7.1 General
7.2 Description
7.3 Limits of use
32 7.4 Discharge coefficient
7.5 Expansibility [expansion] factor
7.6 Pressure loss
7.7 Installation requirements
34 Annex A (informative) An example of the calculations in 5.1.2
37 Bibliography
BSI PD ISO/TR 15377:2018
$167.15