BSI 23/30453812 DC:2023 Edition
$13.70
BS EN IEC 62271-208. High-voltage switchgear and controlgear – Part 208. Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations
Published By | Publication Date | Number of Pages |
BSI | 2023 | 52 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
9 | 1 Scope 2 Normative references |
10 | 3 Terms and definitions |
11 | 4 Evaluation requirements 4.1 General |
12 | 4.2 Methods of evaluation 4.3 Evaluation of electric fields 4.3.1 HV switchgear assemblies 4.3.2 HV/LV prefabricated substations 4.4 Evaluation of magnetic fields 4.4.1 HV switchgear assemblies |
13 | 4.4.2 HV/LV prefabricated substations |
14 | 5 Measurements 5.1 General 5.2 Measuring instruments 5.3 Measurement procedures 5.3.1 General |
15 | 5.4 Hot-spot measurement procedure 5.4.1 Electric field |
18 | 5.4.2 Magnetic field |
20 | 5.4.3 Background fields 5.4.4 Environmental factors 5.4.4.1 Electric field measurement 5.4.4.2 Magnetic field measurement 5.4.4.3 Other conditions |
21 | 5.5 Isoline measurement procedure 5.5.1 General 5.5.2 Measurement height(s) 5.5.3 Intervals between measurement points |
22 | 5.5.4 Background fields 5.5.5 Environmental factors 5.6 Measurement set-up 5.6.1 General 5.6.2 Hot spot measurement set-up |
24 | 5.6.3 Isoline measurement set-up |
25 | 5.6.4 External connections |
26 | 5.6.5 Additional provisions for HV/LV prefabricated substations 5.6.5.1 Electric field 5.6.5.2 Magnetic field 6 Calculations 6.1 General |
27 | 6.2 Software 6.3 Calculation procedures 6.4 Results 6.5 Validation |
28 | 7 Documentation 7.1 Characteristics of the HV switchgear assembly or prefabricated substation 7.2 Evaluation method 7.3 Presentation of the measurement results 7.4 Presentation of the calculation results |
30 | Annex A (informative) Presentation of E or B field measurement data – Examples for a typical HV/LV prefabricated substation A.1 Presentation of Hot-spot B-field measurement results A.1.1 Hot spot locations |
31 | A.1.2 Hot spot locations with its E or B field values A.1.3 Variation of the E or B field as a function of the distance |
32 | A.1.4 Field variation around substation at hot spot locations A.1.5 Background fields A.2 Presentation of Isoline B-field measurement results A.2.1 Location of measurement points on Isoline |
33 | A.2.2 Background fields |
34 | A.2.3 Example of an Isoline measurement on a 250kVA transformer substation |
35 | Annex B (informative) Examples of analytical solutions to benchmark EMF calculations B.1 Magnetic field |
43 | B.2 Electric field |