BS ISO/IEC 24775-6:2021
$215.11
Information technology. Storage management – Fabric
Published By | Publication Date | Number of Pages |
BSI | 2021 | 214 |
The Storage Management Technical Specification, Part 6 Fabric defines management profiles for Autonomous (top level) profiles for programs and devices whose central function is providing support for storage networking. This version of Storage Management Technical Specification, Part 6 Fabric includes these autonomous profiles:
-
Fabric
This profile defines the model and functions of a storage network including topology and zoning control.
-
Switch
This profile defines the model and functions of a Fibre Channel Switch including state, status, and control of the device and itās connections and product information,
-
Extender
This profile defines the model and functions of a networking device that allows for fibre channel to be extended over other networks, and specifically over IP (FCIP).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
8 | Blank Page |
17 | List of Figures |
19 | List of Tables |
25 | Foreword |
27 | 1 Scope |
29 | 2 Normative References 2.1 Approved references 2.2 References under development 2.3 Other references |
31 | 3 Terms, Definitions, Symbols, Abbreviations, and Conventions |
33 | 4 Fabric Profile 4.1 Synopsis |
34 | 4.2 Description 4.2.1 Instance Diagram 4.2.2 SANS and Fabrics as AdminDomains |
35 | 4.2.3 Fabrics and Topology 4.2.4 Systems and NetworkPorts |
36 | 4.2.5 N Port Virtualization (NPIV) |
37 | 4.2.6 Zoning |
40 | 4.2.7 Conditional Classes and Properties 4.3 Health and Fault Management 4.4 Cascading Considerations 4.5 Methods of this Profile 4.5.1 Extrinsic Methods of the Profile |
41 | 4.5.2 CreateZoneSet 4.5.3 CreateZone |
42 | 4.5.4 CreateZoneAlias 4.5.5 CreateZoneMembershipSettingData |
43 | 4.5.6 AddZone 4.5.7 AddZoneMembershipSettingData 4.5.8 AddZoneAlias |
44 | 4.5.9 ActivateZoneSet 4.5.10 SessionControl 4.6 Use Cases 4.6.1 Fabric Identifier |
45 | 4.6.2 FCPort OperationalStatus 4.6.3 Switch ComputerSystem OperationalStatus |
46 | 4.7 CIM Elements 4.7.1 Overview |
48 | 4.7.2 CIM_ActiveConnection 4.7.3 CIM_AdminDomain (Fabric) |
49 | 4.7.4 CIM_AdminDomain (SAN) |
50 | 4.7.5 CIM_Component (Platform to Fabric) 4.7.6 CIM_Component (Switch to Fabric) 4.7.7 CIM_ComputerSystem (Host Platform) |
51 | 4.7.8 CIM_ComputerSystem (Partitioned Switch) |
52 | 4.7.9 CIM_ComputerSystem (Storage Platform) 4.7.10 CIM_ComputerSystem (Switch) |
53 | 4.7.11 CIM_ConnectivityCollection |
54 | 4.7.12 CIM_ContainedDomain 4.7.13 CIM_DeviceSAPImplementation (Non-Switch to FCPort) 4.7.14 CIM_DeviceSAPImplementation (Switch to FCPort) |
55 | 4.7.15 CIM_ElementCapabilities (ZoneCapabilities to Fabric.) 4.7.16 CIM_ElementCapabilities (ZoneCapabilities to Switch.) 4.7.17 CIM_ElementSettingData (ZoneMembershipSettingData to Zone) |
56 | 4.7.18 CIM_FCActiveConnection 4.7.19 CIM_FCPort (Host FCPort) |
57 | 4.7.20 CIM_FCPort (Host NPIV FCPort) |
58 | 4.7.21 CIM_FCPort (Partitioned Switch FCPort) |
60 | 4.7.22 CIM_FCPort (Storage FCPort) |
61 | 4.7.23 CIM_FCPort (Switch FCPort) |
62 | 4.7.24 CIM_HostedAccessPoint (AdminDomain to ProtocolEndpoint) 4.7.25 CIM_HostedAccessPoint (ComputerSystem to ProtocolEndpoint) |
63 | 4.7.26 CIM_HostedCollection (Fabric to ConnectivityCollection) 4.7.27 CIM_HostedCollection (System to LogicalPortGroup) 4.7.28 CIM_HostedCollection (Zones or ZoneSets to Fabric) |
64 | 4.7.29 CIM_HostedCollection (Zones or ZoneSets to Switch) 4.7.30 CIM_HostedDependency |
65 | 4.7.31 CIM_LogicalPortGroup 4.7.32 CIM_MemberOfCollection (ConnectivityCollection to ProtocolEndpoint) |
66 | 4.7.33 CIM_MemberOfCollection (LogicalPortGroup to FCPort) 4.7.34 CIM_MemberOfCollection (ZoneSet to Zone) 4.7.35 CIM_ProtocolEndpoint |
67 | 4.7.36 CIM_SystemDevice (Non-Switch FCPort to Fabric) 4.7.37 CIM_SystemDevice (Non-Switch FCPort to Platform) 4.7.38 CIM_SystemDevice (Switch FCPort to Switch) |
68 | 4.7.39 CIM_Zone (Active) 4.7.40 CIM_Zone (Inactive) 4.7.41 CIM_ZoneCapabilities |
70 | 4.7.42 CIM_ZoneMembershipSettingData 4.7.43 CIM_ZoneSet (Active) 4.7.44 CIM_ZoneSet (Inactive) |
71 | 4.7.45 CIM_ZoneSettingData (ZoneMembershipSettingData to Zone) |
73 | 5 Enhanced Zoning and Enhanced Zone Control Profile 5.1 Synopsis 5.2 Description 5.3 Health and Fault Management 5.4 Cascading Considerations 5.5 Methods of this Profile 5.5.1 CreateZoneAlias 5.5.2 AddZoneAlias |
74 | 5.6 Use Cases 5.7 CIM Elements 5.7.1 Overview 5.7.2 CIM_ElementSettingData (ZoneMembershipSettingData to NamedAddressCollection) 5.7.3 CIM_HostedCollection (AdminDomain to Collection) |
75 | 5.7.4 CIM_HostedCollection (ComputerSystem to Collection) 5.7.5 CIM_MemberOfCollection 5.7.6 CIM_NamedAddressCollection |
76 | 5.7.7 CIM_ZoneService (Zone Service) |
77 | 6 Zone Control Profile 6.1 Synopsis 6.2 Description 6.3 Durable Names and Correlatable IDs of the Profile 6.4 Instrumentation Requirements 6.5 Health and Fault Management 6.6 Cascading Considerations |
78 | 6.7 Methods of this Profile 6.7.1 CreateZoneSet 6.7.2 CreateZone 6.7.3 CreateZoneMembershipSettingData 6.7.4 AddZone 6.7.5 AddZoneMembershipSettingData |
79 | 6.7.6 ActivateZoneSetWithJob 6.7.7 ActivateZoneSet |
80 | 6.7.8 SessionControlWithJob |
81 | 6.7.9 SessionControl 6.7.10 Intrinsics for removing a zone from a zone set |
82 | 6.7.11 Intrinsics for removing a zone alias from a zone 6.7.12 Intrinsics for removing a zone member from a zone or zone alias 6.7.13 Intrinsic for deleting a zone member 6.7.14 Intrinsic for deleting a zone, zone alias, or zone set 6.7.15 AddZoneMembershipSettingDataWithRole |
83 | 6.7.16 CreateZoneMembershipSettingDataWithRole 6.8 Use Cases 6.9 CIM Elements 6.9.1 Overview 6.9.2 CIM_HostedService (Fabric (AdminDomain) to ZoneService) |
84 | 6.9.3 CIM_HostedService (Switch (ComputerSystem) to ZoneService) 6.9.4 CIM_ZoneService (Zone Service) |
87 | 7 FDMI Profile 7.1 Synopsis 7.2 Description |
88 | 7.3 Health and Fault Management 7.4 Cascading Considerations 7.5 Methods of this Profile 7.6 Use Cases |
89 | 7.7 CIM Elements 7.7.1 Overview 7.7.2 CIM_Component (Host Server to Fabric) |
90 | 7.7.3 CIM_ComputerSystem (Host Server) 7.7.4 CIM_ControlledBy |
91 | 7.7.5 CIM_ElementSoftwareIdentity 7.7.6 CIM_FCPort (Host FCPort) |
92 | 7.7.7 CIM_HostedCollection (System to LogicalPortGroup) 7.7.8 CIM_InstalledSoftwareIdentity |
93 | 7.7.9 CIM_MemberOfCollection (LogicalPortGroup to FCPort) 7.7.10 CIM_PhysicalPackage (HBA Package) |
94 | 7.7.11 CIM_PortController 7.7.12 CIM_Product (HBA Product) |
95 | 7.7.13 CIM_ProductPhysicalComponent 7.7.14 CIM_Realizes 7.7.15 CIM_SoftwareIdentity (Driver) |
96 | 7.7.16 CIM_SoftwareIdentity (Firmware) 7.7.17 CIM_SoftwareIdentity (Option ROM) |
97 | 7.7.18 CIM_SystemDevice (ComputerSystem to FCPort) 7.7.19 CIM_SystemDevice (ComputerSystem to PortController) |
99 | 8 Fabric Views Profile 8.1 Description 8.1.1 Synopsis 8.1.2 Overview 8.1.3 Goals of View Classes |
100 | 8.1.4 Specific Requirements and Objectives of View Classes 8.1.5 Class Diagram for Fabric Views View Classes |
101 | 8.1.6 View Class Capabilities 8.1.7 Topology View |
102 | 8.1.8 FCSwitch View 8.2 Health and Fault Management Consideration |
103 | 8.3 Cascading Considerations 8.4 Methods of the Profile 8.5 Use Cases 8.6 CIM Elements 8.6.1 Overview 8.6.2 CIM_ElementCapabilities (View Capabilities) |
104 | 8.6.3 CIM_ElementView (View to FC Port) 8.6.4 CIM_ElementView (View to Switch) |
105 | 8.6.5 CIM_ViewCapabilities 8.6.6 CIM_ConcreteComponentView (FCSwitchView to Fabric) 8.6.7 CIM_ConcreteComponentView (FCTopologyView to Fabric) |
106 | 8.6.8 CIM_FCSwitchView |
107 | 8.6.9 CIM_FCTopologyView |
109 | 9 Virtual Fabrics 9.1 Synopsis 9.2 Description |
112 | 9.3 Health and Fault Management Consideration 9.4 Cascading Considerations 9.5 Methods of the Profile 9.6 Use Cases |
113 | 9.7 CIM Elements 9.7.1 Overview 9.7.2 CIM_Component (AdminDomain to Partitioning CS) 9.7.3 CIM_ElementConformsToProfile (SAN AdminDomain to Virtual Fabrics RegisteredProfile) |
115 | 10 Switch Profile 10.1 Synopsis 10.2 Description 10.2.1 Switch Profile |
117 | 10.2.2 FC Port Settings and Capabilities |
118 | 10.2.3 Trunking |
119 | 10.2.4 DetailedPortState, PortAvailability, OperationalStatus, and EnabledState |
120 | 10.2.5 Conditional Classes and Properties 10.3 Health and Fault Management 10.4 Cascading Considerations 10.5 Methods of this Profile 10.6 Use Cases |
121 | 10.7 CIM Elements 10.7.1 Overview |
122 | 10.7.2 CIM_ComputerSystem (Partitioned Switch) |
123 | 10.7.3 CIM_ComputerSystem (Switch) |
124 | 10.7.4 CIM_ComputerSystemPackage |
125 | 10.7.5 CIM_ElementCapabilities (FCPort to FCPortCapabilities) 10.7.6 CIM_ElementCapabilities (System to FCSwitchCapabilities) 10.7.7 CIM_ElementSettingData (FCPortSettings to FCPort) |
126 | 10.7.8 CIM_ElementSettingData (FCSwitchSettings to ComputerSystem) 10.7.9 CIM_ElementStatisticalData (FCPortRateStatistics to FCPort) 10.7.10 CIM_ElementStatisticalData (FCPortStatistics to FCPort) |
127 | 10.7.11 CIM_FCPort (Partitioned Switch FCPort) |
128 | 10.7.12 CIM_FCPort (Switch FCPort) |
130 | 10.7.13 CIM_FCPortCapabilities 10.7.14 CIM_FCPortRateStatistics |
131 | 10.7.15 CIM_FCPortSettings 10.7.16 CIM_FCPortStatistics |
133 | 10.7.17 CIM_FCSwitchCapabilities |
134 | 10.7.18 CIM_FCSwitchSettings |
135 | 10.7.19 CIM_HostedCollection (Redundancy Set) 10.7.20 CIM_HostedCollection (Statistics Collection) 10.7.21 CIM_MemberOfCollection (FCPort to RedundancySet) |
136 | 10.7.22 CIM_MemberOfCollection (NetworkPortStatistics to StatisticalCollection) 10.7.23 CIM_ProtocolEndpoint |
137 | 10.7.24 CIM_RedundancySet 10.7.25 CIM_StatisticsCollection 10.7.26 CIM_SystemDevice |
139 | 11 Blades Profile 11.1 Synopsis 11.2 Description 11.3 Instance Diagram 11.4 Health and Fault Management |
140 | 11.5 Cascading Considerations 11.6 Methods of this Profile 11.7 Use Cases 11.8 CIM Elements 11.8.1 Overview 11.8.2 CIM_LogicalModule |
141 | 11.8.3 CIM_ModulePort 11.8.4 CIM_PhysicalPackage (Logical Module) |
142 | 11.8.5 CIM_Product (Blade) 11.8.6 CIM_ProductPhysicalComponent 11.8.7 CIM_Realizes (Logical Module Package) |
143 | 11.8.8 CIM_SystemDevice (Logical Module) |
145 | 12 Switch Partitioning 12.1 Synopsis 12.2 Description |
147 | 12.3 Health and Fault Management Consideration 12.4 Cascading Considerations 12.5 Methods of the Profile 12.6 Use Cases 12.7 CIM Elements 12.7.1 Overview |
148 | 12.7.2 CIM_ComputerSystem (Partitioned) 12.7.3 CIM_ComputerSystem (Partitioning) |
149 | 12.7.4 CIM_ElementCapabilities (Association between NetworkPort and NetworkPortCapabilities) 12.7.5 CIM_ElementConformsToProfile (Partitioning ComputerSystem to Switch Partitioning RegisteredProfile) |
150 | 12.7.6 CIM_ElementSettingData (Association between NetworkPort and NetworkPortSettings) 12.7.7 CIM_FCPort (Partitioned) |
151 | 12.7.8 CIM_HostedDependency (NetworkPort to FCPort) 12.7.9 CIM_HostedDependency (Partitioning CS to Partitioned CS) |
152 | 12.7.10 CIM_NetworkPort (Partitioning) 12.7.11 CIM_NetworkPortCapabilities 12.7.12 CIM_NetworkPortSettings |
153 | 12.7.13 CIM_SystemDevice (FCPort to Partitioned ComputerSystem) 12.7.14 CIM_SystemDevice (NetworkPort to ComputerSystem) |
155 | 13 N Port Virtualizer Profile 13.1 Synopsis 13.2 Description |
156 | 13.3 Implementation |
157 | 13.4 Health and Fault Management Consideration 13.5 Cascading Considerations 13.6 Methods of the Profile 13.7 Use Cases 13.8 CIM Elements 13.8.1 Overview |
158 | 13.8.2 CIM_Component (N Port Virtualizer to Fabric) 13.8.3 CIM_ComputerSystem (N Port Virtualizer) 13.8.4 CIM_ComputerSystemPackage (N Port Virtualizer to Physical Package) |
159 | 13.8.5 CIM_DeviceSAPImplementation (ProtocolEndpoint to Gateway FCPort) 13.8.6 CIM_DeviceSAPImplementation (ProtocolEndpoint to NPIV FCPort) |
160 | 13.8.7 CIM_FCActiveConnection (Gateway) 13.8.8 CIM_FCActiveConnection (N Port Virtualiztion) 13.8.9 CIM_FCPort (Fabric NPIV) |
161 | 13.8.10 CIM_FCPort (Gateway) |
162 | 13.8.11 CIM_HostedAccessPoint (N Port Virtualizer System to ProtocolEndpoint) |
163 | 13.8.12 CIM_LogicalIdentity (NPIV Port to Switch Port) 13.8.13 CIM_ProtocolEndpoint (N Port Virtualizer) |
164 | 13.8.14 CIM_SystemDevice (N Port Virtualizer Gateway FCPort to Gateway System) 13.8.15 CIM_SystemDevice (N Port Virtualizer NPIV FCPort to Gateway System) |
165 | 14 Inter Fabric Routing Profile 14.1 Synopsis 14.2 Description 14.2.1 Overview 14.2.2 Switch Topology |
167 | 14.2.3 Identification of Ports |
168 | 14.3 Health and Fault Management Consideration 14.4 Cascading Considerations 14.5 Methods of the Profile 14.6 Use Cases |
169 | 14.7 CIM Elements 14.7.1 Overview 14.7.2 CIM_Component (Backbone Switch to Fabric) 14.7.3 CIM_Component (IFR Switch to Fabric) |
170 | 14.7.4 CIM_ComputerSystem (Backbone Switch) |
171 | 14.7.5 CIM_ComputerSystem (IFR Switch) |
172 | 14.7.6 CIM_FCActiveConnection 14.7.7 CIM_FCPort (IFR FCPort) |
174 | 14.7.8 CIM_ProtocolEndpoint 14.7.9 CIM_SystemDevice |
177 | 15 FCoE Fabric 15.1 Synopsis 15.2 Description |
178 | 15.3 Health and Fault Management Consideration 15.4 Methods of the Profile 15.5 Use Cases |
179 | 15.6 CIM Elements 15.6.1 Overview |
180 | 15.6.2 CIM_AdminDomain (Ethernet Network) 15.6.3 CIM_Component (Switch to Ethernet Network) 15.6.4 CIM_ComputerSystem (Ethernet Switch) |
181 | 15.6.5 CIM_ConnectivityCollection (LANEndpoints to EthernetNetwork) 15.6.6 CIM_DeviceSAPImplementation (Ethernet Switch EthernetPort to LANEndpoint) |
182 | 15.6.7 CIM_DeviceSAPImplementation (Non-Switch EthernetPort to LANEndpoint) 15.6.8 CIM_ActiveConnection (Links transported over Ethernet (FCoE)) 15.6.9 CIM_EthernetPort (Host EthernetPort)) |
183 | 15.6.10 CIM_EthernetPort (Storage EthernetPort) 15.6.11 CIM_EthernetPort (Switch EthernetPort) |
184 | 15.6.12 CIM_HostedAccessPoint (AdminDomain to LANEndpoint) 15.6.13 CIM_HostedAccessPoint (ComputerSystem to LANEndpoint) |
185 | 15.6.14 CIM_HostedCollection (Ethernet Network AdminDomain to ConnectivityCollection) 15.6.15 CIM_HostedDependency (ComputerSystem (Ethernet Switch) to Partitioning ComputerSystem) |
186 | 15.6.16 CIM_HostedDependency (FCPort to EthernetPort) 15.6.17 CIM_LANEndpoint (Ethernet ProtocolEndpoint) |
187 | 15.6.18 CIM_MemberOfCollection (ConnectivityCollection to LANEndpoint) 15.6.19 CIM_SystemDevice (Switch EthernetPort to Switch) 15.6.20 CIM_SystemDevice (non-Switch EthernetPort to Ethernet AdminDomain) |
189 | Annex A (informative) SMI-S Information Model |
191 | Annex B (Informative) Structure of Fabric Profiles B.1 Purpose of this Annex B.2 Overview of Fabric Part Profiles |
193 | B.3 Property and Association Requirements B.3.1 CIM_AdminDomain Requirements |
196 | B.3.2 CIM_ComputerSystem Requirements |
204 | B.3.3 Port Requirements |