BS IEC 62153-4-6:2017
$142.49
Metallic cables and other passive components test methods – Electromagnetic compatibility (EMC). Surface transfer impedance. Line injection method
Published By | Publication Date | Number of Pages |
BSI | 2017 | 26 |
This part of IEC 62153 determines the screening effectiveness of a shielded metallic communication cable by applying a well-defined current and voltage to the screen of the cable and measuring the induced voltage in order to determine the surface transfer impedance.
Measurements in the frequency range from a few kHz up to and above 1 GHz can be made with the use of normal high frequency instrumentation.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | CONTENTS |
7 | FOREWORD |
9 | 1 Scope 2 Normative references 3 Terms and definitions 4 Physical background |
10 | 5 Test set-up 5.1 General |
11 | 5.2 Equipment 5.3 Injection feature Figures Figure 1 – Complete installation |
12 | Figure 2 – Assembled injection feature for the transmission type line,Injection method – Parts list |
13 | Figure 3 – Upper part of injection feature – Position 1 Figure 4 – Lower part of injection feature – Position 2 |
14 | 5.4 Impedance of inner circuit Figure 5 – Impedance matching part ofinjection feature – Position 3 Figure 6 – Insert for adapting the different sizes ofthe cables under test – Position 4 |
15 | 6 Preparation of the test sample 6.1 General |
16 | 6.2 Sample length Figure 7 – Preparation of the cable under test (CUT) Figure 8 – Additional screening of connectors on the cable under test (CUT) |
17 | 6.3 Screened symmetrical cables 6.4 Screened multi-conductor cables 7 Measurement 7.1 General Figure 9 – Preparation of symmetrical samples |
18 | 7.2 Measurement precautions 7.2.1 Reduced primary current 7.2.2 Uncontrolled currents 7.2.3 Inhomogeneities of cable screens around the circumference 7.3 Calibration |
19 | 7.4 Measuring procedure Figure 10 – Calibration set-up |
20 | Figure 11 – Far end measuring set-up |
21 | 7.5 Evaluation of the test results |
22 | 8 Expression of test results 8.1 Expression 8.2 Normalised screening attenuation |
23 | 8.3 Temperature correction 8.4 Test report 9 Requirement |
24 | Bibliography |