Shopping Cart

No products in the cart.

BS EN ISO 10819:2013+A1:2019

$167.15

Mechanical vibration and shock. Hand-arm vibration. Measurement and evaluation of the vibration transmissibility of gloves at the palm of the hand

Published By Publication Date Number of Pages
BSI 2019 40
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This International Standard specifies a method for the laboratory measurement, data analysis, and reporting of the vibration transmissibility of a glove with a vibration-reducing material that covers the palm, fingers, and thumb of the hand. This International Standard specifies vibration transmissibility in terms of vibration transmitted from a handle through a glove to the palm of the hand in one-third-octave frequency bands with centre frequencies of 25 Hz to 1 250 Hz.

The measurement procedure specified in this International Standard can also be used to measure the vibration transmissibility of a material that is being evaluated for use to cover a handle of a machine or for potential use in a glove. However, results from this test cannot be used to certify that a material used to cover a handle meets the requirements of this International Standard to be classified as an antivibration covering. A material tested in this manner could later be placed in a glove. When this is the case, the glove needs to be tested in accordance with the measurement procedure of this International Standard and needs to meet the vibration attenuation performance requirements of this International Standard in order to be classified as an antivibration glove.

NOTE ISO 13753[1] defines a method for screening materials used for vibration attenuation on the handles of machines and for gloves.

PDF Catalog

PDF Pages PDF Title
2 National foreword
4 European foreword
Anchor 22
Foreword to amendment A1
6 Annex ZA (informative) Relationship between this European Standard and the essential health and safety requirements of Regulation (EU) 2016/425 aimed to be covered
9 Foreword
10 Introduction
11 1 Scope
2 Normative references
12 3 Terms and definitions
4 Symbols and abbreviations
13 5 Measuring principle and equipment
5.1 General principle and setup
14 5.2 Measuring equipment
5.2.1 General requirements
5.2.2 Transducer mounting
15 5.2.3 Frequency analyses
5.2.4 Grip force measuring system
5.2.5 Feed force measuring system
16 5.3 Vibration excitation system
5.3.1 Characteristics of the instrumented handle
17 5.3.2 Position of the excitation system
5.3.3 Performance
6 Measurement conditions and procedure
6.1 Measurement conditions
6.1.1 Test subjects
6.1.2 Test gloves
6.1.3 Test conditions
6.1.4 Test subject’s posture
18 6.1.5 Position of the palm adaptor in glove vibration transmissibility tests
19 6.2 Vibration signal
21 6.3 Test procedure
6.3.1 Preparation
6.3.2 Measurements with the bare adaptor
22 6.3.3 Measurements with gloved hand
6.3.4 Measurements with resilient material
6.3.5 Required number of tests
7 Evaluation of results
7.1 Calculation of transmissibility
7.1.1 General
23 7.1.2 One-third-octave frequency ranges
7.1.3 Frequency-weighted acceleration values
24 7.2 Bare palm adaptor vibration transmissibility
7.2.1 One-third-octave vibration transmissibility
25 7.2.2 Frequency-weighted vibration transmissibility
7.3 Uncorrected glove vibration transmissibility
7.3.1 One-third-octave vibration transmissibility
26 7.3.2 Frequency-weighted vibration transmissibility
7.4 Corrected glove vibration transmissibility
7.4.1 One-third-octave vibration transmissibility
7.4.2 Frequency-weighted vibration transmissibility
8 Calculation of statistical values
8.1 General
27 8.2 One-third-octave vibration transmissibility
8.3 Frequency-weighted vibration transmissibility
28 9 Criteria for designating gloves as antivibration gloves
9.1 General
9.2 Vibration transmissibility of the gloves
9.3 Construction of the gloves
9.3.1 Glove vibration-reducing material thickness
29 9.3.2 Measurement of the thickness of the glove vibration-reducing material
31 9.3.3 Lacks (gap) between the palm and thumb sections of glove vibration-reducing material
9.3.4 Requirements within the European Union
10 Test report
33 Annex A (informative) Examples of handles with force and acceleration measuring systems
36 Annex B (normative) Further requirements for protective gloves against vibration
39 Bibliography
BS EN ISO 10819:2013+A1:2019
$167.15