BS EN 62271-206:2011
$142.49
High-voltage switchgear and controlgear – Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kVkV and up to and including 52 kV
Published By | Publication Date | Number of Pages |
BSI | 2011 | 28 |
This part of IEC 62271 is applicable to voltage presence indicating systems (VPIS) incorporated in a.c. switchgear and controlgear covered by IEC 62271-200 or IEC 62271-201.
Voltage presence indicating systems are devices used to provide information to operators about the voltage condition of the main circuit of the switchgear in which they are installed.
The indication of VPIS alone is not sufficient to prove that the system is dead: if operating procedures make it mandatory, relevant voltage detectors according to IEC 61243-1, IEC 61243-2 and IEC 61243-5 should be used.
This standard is also applicable to phase comparators specifically designed for use with VPIS.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
9 | 1 General 1.1 Scope 1.2 Normative references 2 Service conditions |
10 | 3 Terms and definitions 4 Ratings |
11 | 4.1 Rated voltage 4.2 Rated insulation level 4.3 Rated frequency 5 Design and construction 5.1 General 5.2 Threshold values for voltage presence indication |
12 | 5.3 Indication and perceptibility 5.4 Coupling element and voltage limiting device Tables Table 1 – Indication corresponding to “voltage present” |
13 | 5.5 Marking 5.6 Phase comparator and connecting point |
14 | 5.7 Electromagnetic compatibility (EMC) |
15 | 6 Type tests 6.1 General |
16 | 6.2 Arrangement, assembly, marking, and instructions for use 6.3 Clear indication of VPIS 6.4 Response time of VPIS |
17 | 6.5 Dielectric strength of the coupling element of VPIS 6.6 Maximum current delivered by the connecting point 6.7 Voltage limiting device |
18 | 6.8 Clear perceptibility of visual indication |
19 | 6.9 Impact resistance 6.10 Clear indication of phase comparators |
20 | 6.11 Electromagnetic compatibility tests (EMC) 6.12 Indication until power source is exhausted |
21 | 7 Routine tests 7.1 General 7.2 Clear indication 8 Guide to the selection of VPIS 9 Information to be given with enquiries, tenders and orders 10 Instructions for use 10.1 General 10.2 Instructions for use of VPIS |
22 | 10.3 Instructions for use of phase comparators 11 Safety |
23 | Figures Figure 1 – Voltage presence indicating system Table 2 – Sequence of type tests for VPIS and phase comparators (PC) |
24 | Figure 2 – Examples for measuring the response time |
25 | Figure 3 – Test set-up for perceptibility of visual indication |
26 | Bibliography |