BS EN 62150-2:2011

$142.49

Fibre optic active components and devices. Test and measurement procedures – ATM-PON transceivers

Published By Publication Date Number of Pages
BSI 2011 28
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 62150 specifies testing and measuring procedures for fibre optic transceivers for asynchronous-transfer-mode passive optical network (ATM-PON) systems recommended by ITU-T G.983.1. These testing procedures correspond to methods of examining whether the transceivers satisfy the performance specifications defined in IEC 62149-5. On the other hand, the measuring procedures correspond to methods of precise measurement for such transceivers. The receiver sections of these transceivers can handle burst signals. Therefore, some procedures described in this standard correspond to the burst signal transmission.

PDF Catalog

PDF Pages PDF Title
6 English
CONTENTS
8 INTRODUCTION
9 1 Scope
2 Normative references
3 Abbreviations and symbols
3.1 Abbreviations
10 3.2 Symbols
4 Standard ambient conditions
5 Apparatus
5.1 Power supply
Table 1 – Ambient conditions for carrying out measurements and tests
11 5.2 Optical power meter
5.3 Variable optical attenuator
5.4 Pulse pattern generator
5.5 Optical splitter
5.6 Oscilloscope
5.7 Optical jumper cable
5.8 BER detector
5.9 Reference Tx and reference Rx
5.10 Calibrated optical spectrum analyzer
5.11 Low-pass filter
12 5.12 Optical-to-electrical (O/E) converter
6 Test sample
7 Testing and measuring procedures
7.1 Rx alarm function
13 Figures
Figure 1 – Testing and measuring configuration for Rx alarm function
14 7.2 Tx shutdown function
Figure 2 – Relation between receiver input power and alarm voltage
15 7.3 Mean launched power: Pmean
Figure 3 – Testing and measuring configuration for transmitter shutdown function
16 Figure 4 – Testing and measuring configuration for mean launched power
Figure 5 – Burst signal pattern
17 7.4 Centroidal wavelength and spectral width
Figure 6 – Testing and measuring configuration for mean launched power
18 7.5 Extinction ratio and mask test
Figure 7 – Testing and measuring configuration for extinction ratio and mask test
19 7.6 Receiver sensitivity (S) and receiver overload (SO)
20 Figure 8 – Testing and measuring configuration for receiver sensitivity and overload
21 Figure 9 – Burst signal patterns for measurement
23 8 Test result
8.1 Required information
8.2 Available information
25 Bibliography