BS EN 60400:2017 – TC:2020 Edition
$280.87
Tracked Changes. Lampholders for tubular fluorescent lamps and starterholders
Published By | Publication Date | Number of Pages |
BSI | 2020 | 243 |
IEC 60400:2017 states the technical and dimensional requirements for lampholders for tubular fluorescent lamps and for starterholders, and the methods of test to be used in determining the safety and the fit of the lamps in the lampholders and the starters in the starterholders. This eighth edition cancels and replaces the seventh edition published in 2008, Amendment 1:2011 and Amendment 2:2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – alignment with ISO/IEC drafting rules; – renumbering of clauses, tables and figures. This bilingual version (2017-12) corresponds to the monolingual English version, published in 2017-06. The French version of this standard has not been voted upon.
PDF Catalog
PDF Pages | PDF Title |
---|---|
145 | National foreword |
152 | CONTENTS |
155 | FOREWORD |
157 | 1 Scope 2 Normative references |
158 | 3 Terms and definitions |
162 | 4 General requirement |
163 | 5 General conditions for tests |
164 | 6 Electrical rating 7 Classification |
165 | 8 Marking |
167 | 9 Protection against electric shock |
169 | 10 Terminals |
171 | 11 Construction |
176 | 12 Resistance to dust and moisture |
177 | 13 Insulation resistance and electric strength Tables Table 1 – Minimum values of insulation resistance |
178 | 14 Endurance |
179 | 15 Mechanical strength |
181 | 16 Screws, current-carrying parts and connections Table 2 – Torque tests on screws |
183 | 17 Creepage distances and clearances |
184 | Table 3 – Minimum distances for AC sinusoidal voltages up to 30 kHz – Impulse withstand category II |
185 | 18 Resistance to heat, fire and tracking Table 4 – Minimum distances for rated ignition voltages or equivalent peak voltage UP |
190 | 19 Resistance to excessive residual stresses (season cracking) and to rusting |
191 | Figures Figure 1 – Mounting jig for the testing of lampholders |
192 | Figure 2 – Mounting sheet |
193 | Figure 3 – Fixture for the testing of lampholder flexibility |
194 | Figure 4 – Test caps G5, GX5 and G13 |
196 | Figure 5 – Impact test apparatus and mounting support |
197 | Figure 6 – Test cap for the test of Clause 14 for lampholders 2GX13 |
198 | Figure 7 – Ball-pressure apparatus Figure 8 – Bracket for fixing lampholders for the impact test |
200 | Figure 9 – Test cap and test assembly for testing of resistance to heatof lampholders G13, G5 and GX5 with T marking |
202 | Figure 10 – Dimensions of starterholder and holder |
203 | Figure 11 – “Go” plug gauges for starterholders |
204 | Figure 12 – Plug gauge for starterholders for testing contact making and retention |
205 | Figure 13 – Special plug gauge for starterholders for testing contact making |
206 | Figure 14 – Test cap for the test of Clause 14 for lampholders G5 and GX5 Figure 15 – Test cap for the test of Clause 14 for lampholders G13 |
207 | Figure 16 – Test cap for the test of Clause 14 for lampholders 2G13 Figure 18 – Test cap for the test ofClause 14 for lampholders Fa6 Figure 17 – Test cap for the test ofClause 14 for lampholders G20 |
208 | Figure 19 – Test cap for the test of Clause 14 for lampholders G10q, GU10q and GZ10q Figure 20 – Test cap for the test of Clause 14 for lampholders Fa8 |
209 | Figure 21 – Test starter for the test of Clause 14 |
210 | Figure 22 – Test cap for the test of Clause 14 for lampholders R17d |
211 | Figure 23 – Test cap for the test of Clause 14 for lampholders 2G11 |
212 | Figure 24 – Test cap for the test of Clause 14 for lampholders G23 and GX23 |
213 | Figure 25 – Test cap for the test of Clause 14 for lampholders GR8 Figure 26 – Test cap for the test of Clause 14 for lampholders GR10q |
214 | Figure 27 – Test cap for the test of Clause 14 for lampholders GX10q and GY10q |
215 | Figure 28 – Test cap for the test of Clause 14 for lampholders G24, GX24 and GY24 |
216 | Figure 29 – Test cap for the test of Clause 14 for lampholders G32 and GY32 |
217 | Figure 30 – Test cap for the test of 18.1 for lampholders G23 |
218 | Figure 31 – Test cap for the test of 18.1 for lampholders GR8 |
219 | Figure 32 – Test cap for the test of 18.1 for lampholders GR10q |
220 | Figure 33 – Test cap for the test of 18.1 for lampholders GX10q |
221 | Figure 34 – Test cap for the test of 18.1 for lampholders GY10q |
222 | Figure 35 – Test cap for the test of 18.1 for lampholders 2G11 |
223 | Figure 36 – Test cap for the test of 18.1 for lampholders GX23 |
224 | Figure 37 – Test cap for the test of 18.1 for lampholders G24, GX24 and GY24 (1 of 2) |
226 | Figure 38 – Test cap for the test of 18.1 for lampholders G32, GX32 and GY32 (1 of 2) |
228 | Figure 39 – Test cap for the test of Clause 14 for lampholders 2G8 |
229 | Figure 40 – Test cap for the test of Clause 14 for lampholders GX53 |
230 | Figure 41 – Standard test finger (according to IEC 60529:2014) |
231 | Figure 42 – Test cap for the test of Clause 14 for lampholders W4.3×8.5d |
232 | Figure 43 – Test cap for the test of Clause 14 for lampholders GR14q |
233 | Figure 44 – Test cap for the test of Clause 14 for lampholders G28d |
234 | Figure 45 – Test cap for the test of Clause 14 for lampholders 2GX11 |
235 | Figure 46 – Test probes for checking gasket sleeves on lampholders for higher IP protection |
236 | Annex A (normative) Examples of lampholders covered by IEC 60400 Table A.1 – Examples of lampholders covered by IEC 60400 |
237 | Annex B (normative) Season cracking/corrosion test B.1 General B.2 Test cabinet B.3 Test solution Table B.1 – pH adjustment |
238 | B.4 Test procedure |
239 | Annex C (informative) Protection against electric shock – Explanatory details for the installation of lampholders according to 9.2 Figure C.1 – Examples of lampholders |
240 | Annex D (informative) Clauses containing new or more stringent requirements with respect to the previous edition |
241 | Bibliography |