BS EN 1371-2:2015
$142.49
Founding. Liquid penetrant testing – Investment castings
Published By | Publication Date | Number of Pages |
BSI | 2015 | 24 |
This European Standard specifies a liquid penetrant testing method for castings produced by investment casting for general purposes.
NOTE
Investment casting is sometimes referred to as lost-wax casting.
This European Standard applies to all cast metals, except copper-tin and/or copper-tin-lead alloy castings, where copper is the major constituent (see EN 1982 [3]).
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Contents Page |
5 | Foreword |
6 | Introduction |
7 | 1 Scope 2 Normative references 3 Conditions for liquid penetrant testing |
8 | 4 Method of testing 4.1 Operating mode 4.2 Qualification of the operators 4.3 Surface preparation 4.4 Viewing conditions 5 Acceptance criteria 5.1 Indications of discontinuities 5.1.1 General |
9 | 5.1.2 Criteria 5.2 Definition of liquid penetrant indications 5.3 Severity levels 5.3.1 General 5.3.2 Criteria |
10 | 5.3.3 Tables 6 Classification of the indications and interpretation of results 7 Retesting 8 Post cleaning and protection |
11 | 9 Test report Table 1 — Severity levels for liquid penetrant testing — Non-linear indications — Isolated (SP) or clustered (CP) |
12 | Table 2 — Severity levels for liquid penetrant testing – Linear (LP) and aligned (AP) indications Table 3 — Recommended surface finish for liquid penetrant testing |
13 | Annex A (informative) Indicative conversion of severity levels of linear (LP) and aligned (AP) indications Table A.1 — Indicative conversion between the severity levels |
14 | Annex B (informative) Nature of discontinuities and types of corresponding liquid penetrant indications Table B.1 — Nature of discontinuities and types of corresponding liquid penetrant indications |
15 | Annex C (informative) Reference figures – Non-linear clustered indications designated CP Figure C.1 — Non-linear clustered indications designated CP |
16 | Annex D (informative) Reference figures – Linear and aligned indications designated LP and AP Figure D.1 — Linear and aligned indications designated LP and AP |
17 | Annex E (informative) Model of a liquid penetrant test report |
18 | Model (continued) |
19 | Model (continued) |
20 | Annex F (informative) Significant technical changes between this European Standard and the previous edition Table F.1 — Significant technical changes between this European Standard and the previous edition |
21 | Bibliography |