BS 3101:1986
$86.31
Specification for control and interlock circuits primarily associated with flameproof restrained plugs and sockets for use in coal mines
Published By | Publication Date | Number of Pages |
BSI | 1986 | 10 |
This British Standard specifies requirements for control and interlock circuits which are required to be intrinsically safe and which are primarily associated with the pilot contacts of flameproof restrained plugs and sockets for use in coal mines. Provision is made for the control circuit to operate in local or remote control. When a resistor proving system is provided the operational requirements are given in clause 6.
NOTE 1. Appendix A gives recommended operational requirements for equipment using a control circuit complying with this standard.
NOTE 2. The titles of the publications referred to in this standard are listed on the inside back cover.
Specifies characteristics and operating conditions, to ensure that components of control units both local and remote from the supply and control unit are interchangeable. Provides for optional interlock circuits and resistor proving systems.