BS 1363-4:2016+A1:2018

$198.66

13 A plugs, socket-outlets, adaptors and connection units – Specification for 13 A fused connection units switched and unswitched

Published By Publication Date Number of Pages
BSI 2018 58
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of BS 1363 specifies requirements for 13 A fused fixed connection units for household, commercial and light industrial purposes, with particular reference to safety in normal use. The connection units are suitable for the connection of appliances, in a.c. circuits only, operating at voltages not exceeding 250 V r.m.s. at 50 Hz.

Requirements are specified for connection units incorporating a fuse‑link conforming to BS 1362:1973.

Requirements are specified for 13 A connection units with or without associated controlling switches, for flush mounting in suitable enclosures, e.g. boxes conforming to BS 4662:2006+A1:2009, or for surface or panel mounting. Connection units are intended for use with cables conforming to BS 6004:2012 having copper conductors. Connection units with cable outlets are additionally intended for use with flexible cables, conforming to the relevant part of BS EN 50525 (see Annex G), on the load (output) side.

This standard does not apply to connection units incorporating screwless terminals for the connection of external conductors of the following types:

  • flat quick‑connect terminals;

  • insulation‑piercing connecting devices; and

  • twist‑on connecting devices.

NOTE 1 The titles of the publications referred to in this part of BS 1363 are listed in the bibliography.

NOTE 2 Requirements for electromagnetic compatibility are not given for the following reason.

A connection unit is mechanical by nature of construction. A connection unit does not emit intolerable electromagnetic interference and the product is immune from electromagnetic interference.

PDF Catalog

PDF Pages PDF Title
5 Foreword
7 1 Scope
2 Conditions of use
3 Terms and definitions
10 4 General
5 General conditions for type testing
11 Table 1 — Schedule of tests
6 Classification
12 7 Marking and labelling
13 8 Clearances, creepage distances and solid insulation
15 Table 2 — Minimum clearances for basic insulation
16 Table 3 — Minimum creepage distances (mm) for basic insulation
Table 4 — Withstand voltages for insulation types
17 9 Accessibility of live parts
10 Provision for earthing
18 Table 5 — Torque values for screws and nuts
11 Terminals
22 12 (Not used)
13 Construction of connection units
24 Table 6 — Actuator test force
25 14 Resistance to ageing, resistance to humidity and protection provided by enclosures
26 Table 7 — Tightening torque values for cable glands
28 15 Insulation resistance and electric strength
29 Table 8 — Test voltage across the open contacts for verifying the suitability for isolation, referred to the rated voltage and to the altitude where the test is carried out
16 Temperature rise
30 Table 9 — Permitted temperature rises
31 17 Breaking capacity of connection units
18 Normal operation of connection units
32 19 Connection of flexible cables and cable anchorage
33 Table 10 — Cable grip tests related to size of flexible cable
34 20 Mechanical strength
35 21 Screws, current‑carrying parts and connections
36 22 Resistance to heat
37 23 Resistance to abnormal heat and fire
Table 11 — Application of glow‑wire test
38 24 Resistance to excessive residual stresses and to rusting
Figure 19 — Solid link for test on fuse clips (see Clause 20)
39 Figure 21a — Pendulum impact test: General view of apparatus (see Clause 20)
40 Figure 21b — Pendulum impact test: Constructional details of striking elements (see Clause 20)
41 Figure 21c — Pendulum impact test: Constructional details of mounting support for test samples (see Clause 20)
42 Figure 28 — Calibrated link (see A.1)
43 Figure 29 — Calibration jig for calibrated link (see A.2)
45 Annex A (normative)  The construction and calibration of a calibrated link
46 Annex B (normative)  Measurement of clearances and creepage distances
Table B.1 — Minimum values of width X
50 Annex C (normative)  Determination of the Comparative Tracking Index (CTI) and Proof Tracking Index (PTI)
51 Annex D (normative)  Relation between rated impulse withstand voltage, rated voltage and Overvoltage Category
Table D.1 — Rated impulse withstand voltage for connection units energized directly from the low voltage mains
Annex E (normative)  Pollution degree
52 Annex F (normative)  Impulse voltage test
Table F.1 — Test voltages for verifying clearances at sea level
53 Annex G (informative)  Specific structure of BS EN 50525 and its derivation from British Standards and from HD 21 and HD 22 (BS EN 50525‑1:2011, National Annex NA)
Table G.1 — Specific structure of BS EN 50525 and its derivation from British Standards and from HD 21 and HD 22 (BS EN 50525‑1:2011, National Annex NA)
55 Bibliography
BS 1363-4:2016+A1:2018
$198.66