F2976-13 Standard Practice for Determining the Field Performance of Commercial Kitchen Demand Control Ventilation Systems
Published By | Publication Date | Number of Pages |
ASTM | 2013 | 6 |
ASTM F2976-13
Historical Standard: Standard Practice for Determining the Field Performance of Commercial Kitchen Demand Control Ventilation Systems
ASTM F2976
Scope
1.1 This Standard Practice determines the energy savings potential of Commercial Kitchen Demand Control Ventilation (CKDCV) systems by outlining a procedure to measure system performance.
1.1.1 Fan energy savings potential of a Commercial Kitchen Demand Control Ventilation system will be determined.
1.1.2 Thermal energy savings potential of a Commercial Kitchen Demand Control Ventilation system will be determined.
1.2 This Standard Practice applies to commercial kitchen exhaust and supply demand control ventilation system in the following foodservice establishments: Casino hotel foodservice facilities, commercial cafeterias, full service restaurant, hotel foodservice facility, quick service restaurant, school cafeteria, supermarket, health care foodservice facility. See Appendix X1 for descriptions of facilities.
1.3 This CKDCV field test protocol does not apply to other demand control ventilation applications such as building heating, ventilation, and air-conditioning (HVAC) applications or laboratory applications.
1.4 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
commercial kitchen ventilation; demand control ventilation; variable speed exhaust systems
ICS Code
ICS Number Code 91.140.30 (Ventilation and air-conditioning systems)