ASTM-E526 2013
$35.75
E526-08(2013) Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium
Published By | Publication Date | Number of Pages |
ASTM | 2013 | 4 |
ASTM E526-08-Reapproved2013
Historical Standard: Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium
ASTM E526
Scope
1.1 This test method covers procedures for measuring reaction rates by the activation reactions 46Ti(n,p) 46Sc + 47Ti(n, np)46Sc.
1.2 The reaction is useful for measuring neutrons with energies above approximately 4.4 MeV and for irradiation times up to about 250 days (for longer irradiations, see Practice E261).
1.3 With suitable techniques, fission-neutron fluence rates above 109 cm–2·s–1 can be determined. However, in the presence of a high thermal-neutron fluence rate, 46Sc depletion should be investigated.
1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E261.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
activation reaction; cross section; dosimetry; nuclear metrology; pressure vessel surveillance; reaction rate; titanium
ICS Code
ICS Number Code 17.240 (Radiation measurements)
DOI: 10.1520/E0526-08R13