Shopping Cart

No products in the cart.

ASTM-E330/E330M 2021

$34.13

E330/E330M-14(2021) Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference

Published By Publication Date Number of Pages
ASTM 2021 7
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM E330/E330M-14-Reapproved2021

Active Standard: Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference

ASTM E330/E330M

Scope

1.1 This test method describes the determination of the structural performance of exterior windows, doors, skylights, and curtain walls under uniform static air pressure differences, using a test chamber. This test method is applicable to curtain wall assemblies including, but not limited to, metal, glass, masonry, and stone components.2

1.2 This test method is intended only for evaluating the structural performance associated with the specified test specimen and not the structural performance of adjacent construction.

1.3 The proper use of this test method requires a knowledge of the principles of pressure and deflection measurement.

1.4 This test method describes the apparatus and the procedure to be used for applying uniformly distributed test loads to a specimen.

1.4.1 Procedure A (see 11.2) shall be used when a load-deflection curve is not required.

1.4.2 Procedure B (see 11.3) shall be used when a load-deflection curve is required.

1.5 The text of this standard references notes and footnotes which provide explanatory materials. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Keywords

curtain wall; deflection; deformation; distress; door; load; pressure chamber; specimen; support; window;

ICS Code

ICS Number Code 91.060.10 (Walls. Partitions. Facades)

DOI: 10.1520/E0330_E0330M-14R21

ASTM-E330/E330M 2021
$34.13