ASTM-E2267 2004(Redline)
$30.55
E2267-04 Standard Guide for Specifying and Evaluating Performance of Single Family Attached and Detached Dwellings-Indoor Air Quality (Redline)
Published By | Publication Date | Number of Pages |
ASTM | 2004 | 19 |
General Purpose and Intent :
4.1.1 This standard guide is to provide a standardized system for describing performance parameters of single-family attached and detached dwellings. The use of consensus performance standards for housing, can significantly contribute to the removal of barriers to the acceptance of traditional and innovative housing products and systems in the global marketplace. This standard guide in conjunction with the balance of the set of standard guides can also serve to improve communications between producers and consumers leading to enhanced quality and performance of housing.
4.1.2 This standard guide, in conjunction with the balance of the set of standard guides, will be useful to managers of housing procurement projects, homebuilders, designers, product manufacturers, and evaluation services.
Indoor Air Quality Issues :
4.2.1 The environment within a building impacts the health of the building occupants and their satisfaction with the space. While this standard only addresses indoor air quality, this aspect of the indoor environment is an important component of a performance approach to residential buildings.
4.2.2 The performance statements contained in this standard guide are relevant to the procurement of a range of built elements related to the indoor environment, including but not limited to the whole building, the exterior enclosure, HVAC subsystems, local exhaust subsystems, other ventilation subsystems and their components, filtration and air cleaning subsystems, and building materials and furnishings.
1. Scope
1.1 This guide contains suggested performance statements for single family residential buildings (attached and detached) that address indoor air quality performance including indoor air pollution and thermal comfort. These performance statements are not presented as proposed requirements, but are written in permissive language as suggestions that can be used in developing specifications to satisfy user needs.
1.2 This standard guide does not address other aspects of the indoor environment such as lighting and acoustics.
1.3 Performance statements addressing building ventilation and ventilation rates are also included in the standard, since it is premature to base performance only on indoor air pollution, that is, airborne contaminant concentrations. When health authorities have established contaminant concentration limits for residential environments, it may be possible to define indoor air quality performance in terms of contaminant concentrations rather than ventilation.
1.4 This standard guide is one in a series of guides containing performance statements for residential buildings that are intended for use in the procurement, specification and evaluation of one- and two-family dwellings. These companion standard guides include those noted in the Introduction above.
1.5 This standard guide also addresses a number of residential indoor air quality issues that can not be expressed as performance statements at this time. However, they are important enough to include in this guide to at least raise the awareness of those involved in the process of procurement, specification and evaluation. These issues are addressed in .
1.6 This standard guide does not include site planning objectives. However, certain issues addressing the relationship of building to site have been covered, and it is important that these few objectives not be construed as a comprehensive site specification.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D1356 Terminology Relating to Sampling and Analysis of Atmospheres D5116 Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products E241 Guide for Limiting Water-Induced Damage to Buildings E631 Terminology of Building Constructions E779 Test Method for Determining Air Leakage Rate by Fan Pressurization E1465 Practice for Radon Control Options for the Design and Construction of New Low-Rise Residential Buildings E1554 Test Methods for Determining Air Leakage of Air Distribution Systems by Fan Pressurization E1998 Guide for Assessing Depressurization-Induced Backdrafting and Spillage from Vented Combustion Appliances E2151 Terminology of Guides for Specifying and Evaluating Performance of Single Family Attached and Detached Dwellings E2156 Guide for Evaluating Economic Performance of Alternative Designs, Systems, and Materials in Compliance with Performance Standard Guides for Single-Family Attached and Detached Dwellings
Keywords
building performance; indoor air pollution; indoor air quality; residential; ventilation;
ICS Code
ICS Number Code 13.040.20 (Ambient atmospheres)
DOI: 10.1520/E2267-04 ASTM International is a member of CrossRef.