Shopping Cart

No products in the cart.

ASTM-E1290:2008 Edition

$44.96

E1290-08e1 Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement

Published By Publication Date Number of Pages
ASTM 2008 15
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM E1290-08e1

Withdrawn Standard: Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement (Withdrawn 2013)

ASTM E1290

Scope

1.1 This test method covers the determination of critical crack-tip opening displacement (CTOD) values at one or more of several crack extension events, and may be used to measure cleavage crack initiation toughness for materials that exhibit a change from ductile to brittle behavior with decreasing temperature, such as ferritic steels. This test method applies specifically to notched specimens sharpened by fatigue cracking. The recommended specimens are three-point bend [SE(B)], compact [C(T)], or arc-shaped bend [A(B)] specimens. The loading rate is slow and influences of environment (other than temperature) are not covered. The specimens are tested under crosshead or clip gage displacement controlled loading.

1.1.1 The recommended specimen thickness, B, for the SE(B) and C(T) specimens is that of the material in thicknesses intended for an application. For the A(B) specimen, the recommended depth, W, is the wall thickness of the tube or pipe from which the specimen is obtained. Superficial surface machining may be used when desired.

1.1.2 For the recommended three-point bend specimens [SE(B)], width, W, is either equal to, or twice, the specimen thickness, B, depending upon the application of the test. (See 4.3 for applications of the recommended specimens.) For SE(B) specimens the recommended initial normalized crack size is 0.45 ao/W 0.70. The span-to-width ratio (S/W) is specified as 4.

1.1.3 For the recommended compact specimen [C(T)] the initial normalized crack size is 0.45 ao/W 0.70. The half-height-to-width ratio (H/W) equals 0.6 and the width to thickness ratio W/B is specified to be 2.

1.1.4 For the recommended arc-shaped bend [A(B)] specimen, B is one-half the specimen depth, W. The initial normalized crack size is 0.45 < ao/W< 0.70. The span to width ratio, S/W, may be either 3 or 4 depending on the ratio of the inner to outer tube radius. For an inner radius, r1, to an outer radius, r2, ratio of > 0.6 to 1.0, a span to width ratio, S/W, of 4 may be used. For r1/r2 ratios from 0.4 to 0.6, an S/W of 3 may be used.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Bend testing–metallic materials; Brittleness; Clip gage displacement; Cracking–metallic materials; Crack-tip opening displacement (CTOD); Crosshead displacement; CTOD values; C(T) specimen testing; Displacement–metals/alloys; Ductility–metals/alloys; Ferritic steel; Fracture testing–metals/alloys; Loading tests–metals/alloys; Metals and metallic materials; Pin loading; SE(B) specimen testing; Square-section bend specimens; Steel; Structural metals/alloys; Toughness; Tensile properties/testing–metallic materials; Three-point loading

ICS Code

ICS Number Code 77.040.10 (Mechanical testing of metals)

DOI: 10.1520/E1290-08E01

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 FIG. 1
3 Summary of Test Method
Significance and Use
Apparatus
4 FIG. 2
FIG. 3
5 FIG. 4
FIG. 5
6 Specimen Configurations, Dimensions, and Preparation
FIG. 6
FIG. 7
7 FIG. 8
FIG. 9
FIG. 10
8 FIG. 11
9 Procedure
10 Analysis of Experimental Data
FIG. 12
11 FIG. 13
FIG. 14
12 TABLE 1
13 Report
TABLE 2
14 Precision and Bias
TABLE 3
15 REFERENCES
ASTM-E1290
$44.96