Shopping Cart

No products in the cart.

ASTM-D7725 2012

$58.50

D7725-12 Standard Test Method for the Continuous Measurement of Turbidity Above 1 Turbidity Unit (TU)

Published By Publication Date Number of Pages
ASTM 2012 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM D7725-12

Historical Standard: Standard Test Method for the Continuous Measurement of Turbidity Above 1 Turbidity Unit (TU)

ASTM D7725

Scope

1.1 This test method covers the online and inline determination of high-level turbidity in water that is greater than 1.0 turbidity units (TU) in municipal, industrial and environmental usage.

1.2 In principle there are three basic applications for on-line measurement set ups. This first is the slipstream (bypass) sample technique. For the slipstream sample technique a portion of sample is transported out of the process and through the measurement apparatus. It is then either transported back to the process or to waste. The second is the in-line measurement where the sensor is brought directly into the process (see Figure 8). The third basic method is for in-situ monitoring of sample waters. This principle is based on the insertion of a sensor into the sample itself as the sample is being processed. The in-situ use in this method is intended for the monitoring of water during any step within a processing train, including immediately before or after the process itself.

1.3 This test method is applicable to the measurement of turbidities greater than 1.0 turbidity unit (TU). The absolute range is dictated by the technology that is employed.

1.4 The upper end of the measurement range is left undefined because different technologies described in this method can cover very different ranges of turbidity.

1.5 Many of the turbidity units and instrument designs covered in this method are numerically equivalent in calibration when a common calibration standard is applied across those designs listed in Table 1. Measurement of a common calibration standard of a defined value will also produce equivalent results across these technologies. This method prescribes the assignment of a determined turbidity values to the technology used to determine those values. Numerical equivalence to turbidity standards is observed between different technologies but is not expected across a common sample. Improved traceability beyond the scope of this method may be practiced and would include the listing of the make and model number of the instrument used to determine the turbidity values.

1.5.1 In this method, calibration standards are often defined in NTU values, but the other assigned turbidity units, such as those in Table 1 are equivalent. For example, a 1 NTU formazin standard is also a 1 FNU, a 1 FAU, a 1 BU, and so forth.

1.6 This standard does not purport to cover all available technologies for high-level turbidity measurement.

1.7 This test method was tested on different waters, and with standards that will serve as surrogates to samples. It is the user’s responsibility to ensure the validity of this test method for waters of untested matrices.

1.8 Those samples with the highest particle densities typically prove to be the most difficult to measure. In these cases, the process monitoring method can be considered with adequate measurement protocols installed.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this procedure.

TABLE 1 Technologies for Measuring Turbidity Greater Than 1 TU that can be used for In-Line or On-Line Applications

Keywords

calibration; calibration verification; continuous; formazin; measurement; monitoring; nephelometer; nephelometric; on-line; standard; styrenedivinylbenzene; turbidimeter; turbidity; turbidity standards

ICS Code

ICS Number Code 13.060.60 (Examination of water for physical properties)

DOI: 10.1520/D7725-12

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
TABLE 1
3 Significance and Use
Safety
4 Interferences
Apparatus
5 FIG. 1
6 FIG. 2
FIG. 3
FIG. 4
7 Purity of Reagents
Reagents
FIG. 5
8 Instrument Installation, Sample Lines and Sampling
FIG. 6
9 FIG. 7
FIG. 8
10 Calibration and Calibration Verification
11 Procedure
12 Results
Quality Control/Quality Assurance
Precision and Bias
13 Keywords
X1. STABILITY OF FORMAZIN
X1.1
TABLE X1.1
14 X2. PROCEDURE FOR SEASONING GLASSWARE WHEN PREPARING CALIBRATION STANDARDS
X2.1 Introduction:
X2.2 Procedure:
X3. SELECTION CRITERIA FLOWCHART FOR TURBIDIMETERS.
X3.1 Introduction
X3.2
TABLE X1.2
15 X4. Examples Depicting the Demonstration of Capability for High Range Turbidity Measurement.
X4.1 Example 1
16 FIG. 10
17 X4.2 Demonstration of On-Line Turbidity Data Usage to Confirm Water of Suitable Turbidity for Drinking Water Filtration Plant Applications
FIG. 11
18 X4.3 Demonstration of Turbidity Data Usage to Monitoring or Drinking Water Filtration Plant Post Filtration Applications
TABLE X4.1
TABLE X4.2
FIG. 12
19 X4.4 Continuous Monitoring of Turbidity in Southwestern Ohio Rivers Using a Modified On-Line Method
FIG. 13
20 FIG. 14
FIG. 15
FIG. 16
21 FIG. 17
FIG. 18
22 X4.5 Demonstration of Turbidity Data Usage with a Backscatter Technology
FIG. 19
FIG. 20
23 FIG. 21
FIG. 22
24 REFERENCES
ASTM-D7725 2012
$58.50