ASTM-D3094 2000
$35.75
D3094-00 Standard Test Method for Seepage Rate of Aerosol Products
Published By | Publication Date | Number of Pages |
ASTM | 2000 | 3 |
ASTM D3094-00
Historical Standard: Standard Test Method for Seepage Rate of Aerosol Products
ASTM D3094
Scope
1.1 This test method covers the determination of approximate mass loss due to valve seepage rate of aerosol products by the collection and measurement of gases seeping through the valve and into a special eudiometer tube, over a relatively short time period.
1.2 It can be shown that the average refrigeration-filled aerosol product seeps to the extent of approximately 3.0 mL when the corresponding mass loss is 0.10 oz (2.9 cm2)/year. This figure is partially based on air content and is subject to variations according to filling conditions. This test method is not considered dependable when applied to pressure-filled, unpurged aerosol products.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
aerosol containers/products; seepage rate; seepage rate of aerosol products
ICS Code
ICS Number Code 55.130 (Aerosol containers)
DOI: 10.1520/D3094-00