Shopping Cart

No products in the cart.

ACI 350.1M 10:2011 Edition

$29.52

350.1M-10 Metric Specification for Tightness Testing of Environmental Engineering Concrete Containment Structures & Comm

Published By Publication Date Number of Pages
ACI 2011 19
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

These test methods give procedures and criteria for tightness testing of environmental engineering concrete structures. They are applicable to liquid and gas containment structures constructed with concrete or a combination of concrete and other materials. This document includes hydrostatic, surcharged hydrostatic, and pneumatic tests. These test methods may involve hazardous materials, operations, and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to establish appropriate safety and health practices and determine the applicability of regulatory limitations before use. Keywords: containment structures; hydrostatic; leakage; pneumatic; reservoirs; tests; tightness; tightness criteria.

PDF Catalog

PDF Pages PDF Title
3 CONTENTS
5 SPECIFICATION
SECTION 1— GENERAL REQUIREMENTS
1.1— Scope
1.1.1 Work specified
1.1.1.1
1.1.1.2
1.1.1.3
1.1.1.4
1.1.1.5
1.1.2 Work not specified
1.2—Definitions
1.3—Description
1.3.1
6 1.3.2
1.4—Submittals
1.4.1 General
1.4.2 Repair procedures
1.4.3 Test reports
1.5—Quality assurance
1.5.1 Duties and responsibilities of Contractor
SECTION 2— HYDROSTATIC TIGHTNESS TEST FOR OPEN OR COVERED CONTAINMENT STRUCTURES
2.1— General
2.1.1 Scope
2.1.1.1
2.1.1.2
2.1.1.3
2.2—Products
2.2.1 Materials
2.2.1.1 Water
2.3—Execution
2.3.1 Test preparation
2.3.1.1
2.3.1.2
2.3.1.3
2.3.1.4
2.3.1.5
2.3.1.6
2.3.1.7
2.3.1.8
7 2.3.1.9
2.3.2 Hydrostatic tightness test—Part 1: Qualitative criteria
2.3.2.1
2.3.2.2
2.3.2.3
2.3.3 Hydrostatic tightness test—Part 2: Quantitative criteria
2.3.3.1
2.3.3.2
2.3.3.3
2.3.3.4
2.3.3.5
2.3.3.6
2.3.3.7
2.3.3.8
2.3.4 Retesting
2.3.4.1
2.3.4.2
2.3.4.3
SECTION 3— SURCHARGED HYDROSTATIC TIGHTNESS TEST FOR CLOSED CONTAINMENT STRUCTURES
3.1— General
3.1.1 Scope
3.1.1.1
3.1.1.2
3.1.1.3
3.2—Products
3.2.1 Materials
3.2.1.1 Water
8 3.3—Execution
3.3.1 Test preparation
3.3.1.1
3.3.1.2
3.3.1.3
3.3.1.4
3.3.1.5
3.3.1.6
3.3.1.7
3.3.1.8
3.3.2 Surcharged hydrostatic tightness test—Part 1: Qualitative criteria
3.3.2.1
3.3.2.2
3.3.3 Surcharged hydrostatic tightness test—Part 2: Quantitative criteria
3.3.3.1
3.3.3.2
3.3.3.3
3.3.3.4
3.3.3.5
3.3.4 Retesting
3.3.4.1
9 3.3.4.2
3.3.4.3
SECTION 4— PNEUMATIC TIGHTNESS TEST FOR CLOSED CONTAINMENT STRUCTURES
4.1— General
4.1.1 Scope
4.1.1.1
4.1.1.2
4.2—Products
4.2.1 Materials
4.2.1.1 Air
4.3—Execution
4.3.1 Test preparation
4.3.1.1
4.3.1.2
4.3.2 Pneumatic tightness test—Part 1: Qualitative criteria
4.3.2.1
4.3.2.2
4.3.2.3
4.3.2.4
4.3.3 Pneumatic tightness test—Part 2: Quantitative criteria
4.3.3.1
4.3.3.2
4.3.3.3
4.3.3.4
4.3.4 Retesting
4.3.4.1
10 4.3.4.2
SECTION 5— COMBINATION HYDROSTATIC-PNEUMATIC TIGHTNESS TEST FOR CLOSED CONTAINMENT STRUCTURES
5.1— General
5.1.1 Scope
5.1.1.1
5.1.1.2
5.1.1.3
5.1.2 Submittals
5.1.2.1
5.2—Products
5.2.1 Materials
5.2.1.1 Water
5.2.1.2 Air
5.3—Execution
5.3.1 Test preparation
5.3.1.1 Hydrostatic tightness test preparation
5.3.1.1.1
5.3.1.1.2
5.3.1.1.3
5.3.1.1.4
5.3.1.1.5
5.3.1.1.6
5.3.1.2 Pneumatic tightness test preparation
5.3.1.2.1
5.3.2 Hydrostatic tightness testing—Parts 1 and 2 and retesting
5.3.2.1
5.3.2.2
5.3.2.3
5.3.3 Pneumatic tightness testing—Parts 1 and 2 and retesting
5.3.3.1
5.3.3.2
5.3.3.3 Pneumatic retesting
5.3.3.3.1
5.3.3.3.2
11 NOTES TO SPECIFIER
General notes
Foreword to Checklists
MANDATORY REQUIREMENTS CHECKLIST
12 OPTIONAL REQUIREMENTS CHECKLIST
SUBMITTALS CHECKLIST
13 COMMENTARY
SECTION R1— GENERAL REQUIREMENTS
R1.1—Scope
R1.1.1.2
R1.1.1.3
R1.1.1.4
R1.1.1.5
R1.1.2 Work not specified
R1.3—Description
R1.3.1
R1.3.2
SECTION R2— HYDROSTATIC TIGHTNESS TEST FOR OPEN OR COVERED CONTAINMENT STRUCTURES
R2.1— General
R2.1.1
R2.1.1.2
14 R2.3.1 Test preparation
R2.3.1.1
R2.3.1.2
R2.3.1.3
R2.3.1.4
R2.3.1.5
R2.3.1.6
R2.3.1.7
R2.3.1.8
R2.3.1.9
R2.3.2 Hydrostatic tightness test—Part 1: Qualitative criteria
R2.3.2.1
R2.3.3 Hydrostatic tightness test—Part 2: Quantitative criteria
R2.3.3.1
R2.3.3.2
R2.3.3.3
15 R2.3.3.4
R2.3.3.5
R2.3.3.6
R2.3.3.7
R2.3.3.8
R2.3.4 Retesting
R2.3.4.1
R2.3.4.2
SECTION R3— SURCHARGED HYDROSTATIC TIGHTNESS TEST FOR CLOSED CONTAINMENT STRUCTURES
R3.1— General
R3.1.1 Scope
R3.1.1.1
R3.1.1.2
R3.3.1 Test preparation
R.3.3.1.1 through R.3.3.1.6.
R3.3.1.7
R3.3.1.8
R3.3.2 Surcharged hydrostatic tightness test—Part 1: Qualitative criteria
R3.3.3 Surcharged hydrostatic tightness test—Part 2: Quantitative criteria
R3.3.3.1
R3.3.3.2
16 R3.3.3.3
R3.3.3.4
R3.3.3.5
R3.3.4 Retesting
R3.3.4.1
SECTION R4— PNEUMATIC TIGHTNESS TEST FOR CLOSED CONTAINMENT STRUCTURES
R4.1— General
R4.1.1
R4.1.1.1
R4.1.1.2
R4.3.1 Test preparation
R4.3.1.1
R4.3.1.2
R4.3.2 Pneumatic tightness test—Part 1: Qualitativecriteria
R4.3.2.1
R4.3.2.3
R4.3.3 Pneumatic tightness test—Part 2: Quantitativecriteria
R4.3.3.2
17 R4.3.3.4
R4.3.4 Retesting
R4.3.4.1
SECTION R5— COMBINATION HYDROSTATIC-PNEUMATIC TIGHTNESS TEST FOR CLOSED CONTAINMENT STRUCTURES
R5.1— General
R5.1.1
R5.1.1.1
R5.1.1.3
R5.3.1 Test preparation
R5.3.1.1 Hydrostatic tightness test preparation
R5.3.1.1.1
R5.3.1.1.3
R5.3.1.1.4
R5.3.1.1.5
R5.3.1.1.6
R5.3.2 Hydrostatic tightness testing—Parts 1 and 2 and retesting
R5.3.2.1
R5.3.3 Pneumatic tightness testing—Parts 1 and 2 and retesting
R5.3.3.1
R5.3.3.2
R5.3.3.3.1
SECTION R6— REFERENCES
ACI 350.1M 10
$29.52