Shopping Cart

No products in the cart.

AECDAILY CT EN 128906 0224:2025 Edition

$65.00

Maximizing Envelope Performance with IMP-Integrated Components

Published By Publication Date Number of Pages
AECDAILY 2025 101
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 Slide 1
2 Slide 2: Maximizing Envelope Performance with IMP-Integrated Components
3 Slide 3
4 Slide 4
5 Slide 5: How to Use This Online Learning Course
6 Slide 6: Purpose and Learning Objectives
7 Slide 7: Contents
8 Slide 8: Achieving a High-Performance Building Envelope
9 Slide 9: Introduction
10 Slide 10: Defining a High-Performance Building Envelope
11 Slide 11: Achieving a High-Performance Building Envelope
12 Slide 12: Barriers to Achieving a High-Performance Building Envelope
13 Slide 13: Barriers to Achieving a High-Performance Building Envelope
14 Slide 14: Who Is Responsible?
15 Slide 15: Features & Benefits of Today’s Insulated Metal Panel System
16 Slide 16: Defining an Insulated Metal Panel (IMP)
17 Slide 17: Characteristics of an IMP System
18 Slide 18: Continuous Air Barrier
19 Slide 19: Continuous Water Barrier
20 Slide 20: Thermal Barrier
21 Slide 21: Vapor Barrier
22 Slide 22: Insulation
23 Slide 23: Comparison of Thermal Insulation
24 Slide 24: Halogen-Free PIR
25 Slide 25: Foamed-in-Place vs. Laminated
26 Slide 26: Thermally Improved Horizontal Joint
27 Slide 27: Horizontal Pressure-Equalized Rainscreen Joinery
28 Slide 28: Horizontal Pressure-Equalized Rainscreen Joinery
29 Slide 29: Vertical Insulated & Pressure-Equalized Rainscreen Joinery
30 Slide 30: Design Flexibility
31 Slide 31: Design Flexibility
32 Slide 32: Integrated Envelope Components
33 Slide 33: Review Question
34 Slide 34: Answer
35 Slide 35: IMP-Integrated Windows
36 Slide 36: IMP-Integrated Windows: Introduction
37 Slide 37: Variety of Models
38 Slide 38: Head Integration
39 Slide 39: Sill Integration
40 Slide 40: Thermal Performance Comparison at Window Head
41 Slide 41: Thermal Performance Comparison at Windowsill
42 Slide 42: Window Head: Nonintegrated vs. Integrated Window
43 Slide 43: Windowsill: Nonintegrated vs. Integrated Window
44 Slide 44: Thermal Performance Comparison at Jamb
45 Slide 45: Examples of IMP-Integrated Window Installations
46 Slide 46: Examples of IMP-Integrated Window Installations
47 Slide 47: IMP-Integrated Sunshades
48 Slide 48: IMP-Integrated Sunshades: Introduction
49 Slide 49: Benefits of Exterior Sunshades
50 Slide 50: Exterior Sunshades vs. Interior Sunshades
51 Slide 51: Exterior Sunshades vs. Interior Sunshades
52 Slide 52: Installation of IMP-Integrated Sunshades
53 Slide 53: Installation of IMP-Integrated Sunshades
54 Slide 54: Outrigger Profile Options
55 Slide 55: Fascia Options
56 Slide 56: Blade Options
57 Slide 57: Infill Options
58 Slide 58: Examples of IMP-Integrated Sunshade Applications
59 Slide 59: Examples of IMP-Integrated Sunshade Applications
60 Slide 60: IMP-Integrated Translucent Daylighting Panels
61 Slide 61: IMP-Integrated Translucent Daylighting Panels: Introduction
62 Slide 62: The Benefits of Using IMP-Integrated Translucent Daylighting Panels
63 Slide 63: Integration Details
64 Slide 64: Examples: IMP-Integrated Translucent Daylighting Panels
65 Slide 65: Examples: IMP-Integrated Translucent Daylighting Panels
66 Slide 66: Review Question
67 Slide 67: Answer
68 Slide 68: IMP-Integrated Louvers
69 Slide 69: IMP-Integrated Louvers: Introduction
70 Slide 70: IMP-Integrated Louvers: Head, Sill, & Jamb Details
71 Slide 71: Aesthetic Feature
72 Slide 72: Blank-Off Panels
73 Slide 73: Blank-Off Panels
74 Slide 74: IMP-Integrated Vertical Tube Support & Accent Fins
75 Slide 75: IMP-Integrated Vertical Tube Support: Introduction
76 Slide 76: Live-Load Floor Deflection
77 Slide 77: Deflection Joint Solutions
78 Slide 78: Possible Solutions
79 Slide 79: Through-Tube Bypass Framing Solution
80 Slide 80: Installation: IMP-Integrated Vertical Tube Support System
81 Slide 81: Installation: IMP-Integrated Vertical Tube Support System
82 Slide 82: Installation: IMP-Integrated Vertical Tube Support System
83 Slide 83: Installation: IMP-Integrated Vertical Tube Support System
84 Slide 84: IMP-Integrated Accent Fins
85 Slide 85: Review Question
86 Slide 86: Answer
87 Slide 87: Case Studies
88 Slide 88: Saint Joseph’s/Candler Hospital, Savannah, GA
89 Slide 89: Saint Joseph’s/Candler Hospital, Savannah, GA
90 Slide 90: Saint Joseph’s/Candler Hospital, Savannah, GA
91 Slide 91: Saint Joseph’s/Candler Hospital, Savannah, GA
92 Slide 92: Saint Joseph’s/Candler Hospital, Savannah, GA
93 Slide 93: NYPA Niagara Warehouse & Office Complex, Lewiston, NY
94 Slide 94: NYPA Niagara Warehouse & Office Complex, Lewiston, NY
95 Slide 95: NYPA Niagara Warehouse & Office Complex, Lewiston, NY
96 Slide 96: Butler County Government Center, Butler, PA
97 Slide 97: Butler County Government Center, Butler, PA
98 Slide 98: Butler County Government Center, Butler, PA
99 Slide 99: Summary
100 Slide 100: Important Points
101 Slide 101: Thank You
AECDAILY CT EN 128906 0224
$65.00