AECDAILY CT EN 128906 0224:2025 Edition
$65.00
Maximizing Envelope Performance with IMP-Integrated Components
Published By | Publication Date | Number of Pages |
AECDAILY | 2025 | 101 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Slide 1 |
2 | Slide 2: Maximizing Envelope Performance with IMP-Integrated Components |
3 | Slide 3 |
4 | Slide 4 |
5 | Slide 5: How to Use This Online Learning Course |
6 | Slide 6: Purpose and Learning Objectives |
7 | Slide 7: Contents |
8 | Slide 8: Achieving a High-Performance Building Envelope |
9 | Slide 9: Introduction |
10 | Slide 10: Defining a High-Performance Building Envelope |
11 | Slide 11: Achieving a High-Performance Building Envelope |
12 | Slide 12: Barriers to Achieving a High-Performance Building Envelope |
13 | Slide 13: Barriers to Achieving a High-Performance Building Envelope |
14 | Slide 14: Who Is Responsible? |
15 | Slide 15: Features & Benefits of Today’s Insulated Metal Panel System |
16 | Slide 16: Defining an Insulated Metal Panel (IMP) |
17 | Slide 17: Characteristics of an IMP System |
18 | Slide 18: Continuous Air Barrier |
19 | Slide 19: Continuous Water Barrier |
20 | Slide 20: Thermal Barrier |
21 | Slide 21: Vapor Barrier |
22 | Slide 22: Insulation |
23 | Slide 23: Comparison of Thermal Insulation |
24 | Slide 24: Halogen-Free PIR |
25 | Slide 25: Foamed-in-Place vs. Laminated |
26 | Slide 26: Thermally Improved Horizontal Joint |
27 | Slide 27: Horizontal Pressure-Equalized Rainscreen Joinery |
28 | Slide 28: Horizontal Pressure-Equalized Rainscreen Joinery |
29 | Slide 29: Vertical Insulated & Pressure-Equalized Rainscreen Joinery |
30 | Slide 30: Design Flexibility |
31 | Slide 31: Design Flexibility |
32 | Slide 32: Integrated Envelope Components |
33 | Slide 33: Review Question |
34 | Slide 34: Answer |
35 | Slide 35: IMP-Integrated Windows |
36 | Slide 36: IMP-Integrated Windows: Introduction |
37 | Slide 37: Variety of Models |
38 | Slide 38: Head Integration |
39 | Slide 39: Sill Integration |
40 | Slide 40: Thermal Performance Comparison at Window Head |
41 | Slide 41: Thermal Performance Comparison at Windowsill |
42 | Slide 42: Window Head: Nonintegrated vs. Integrated Window |
43 | Slide 43: Windowsill: Nonintegrated vs. Integrated Window |
44 | Slide 44: Thermal Performance Comparison at Jamb |
45 | Slide 45: Examples of IMP-Integrated Window Installations |
46 | Slide 46: Examples of IMP-Integrated Window Installations |
47 | Slide 47: IMP-Integrated Sunshades |
48 | Slide 48: IMP-Integrated Sunshades: Introduction |
49 | Slide 49: Benefits of Exterior Sunshades |
50 | Slide 50: Exterior Sunshades vs. Interior Sunshades |
51 | Slide 51: Exterior Sunshades vs. Interior Sunshades |
52 | Slide 52: Installation of IMP-Integrated Sunshades |
53 | Slide 53: Installation of IMP-Integrated Sunshades |
54 | Slide 54: Outrigger Profile Options |
55 | Slide 55: Fascia Options |
56 | Slide 56: Blade Options |
57 | Slide 57: Infill Options |
58 | Slide 58: Examples of IMP-Integrated Sunshade Applications |
59 | Slide 59: Examples of IMP-Integrated Sunshade Applications |
60 | Slide 60: IMP-Integrated Translucent Daylighting Panels |
61 | Slide 61: IMP-Integrated Translucent Daylighting Panels: Introduction |
62 | Slide 62: The Benefits of Using IMP-Integrated Translucent Daylighting Panels |
63 | Slide 63: Integration Details |
64 | Slide 64: Examples: IMP-Integrated Translucent Daylighting Panels |
65 | Slide 65: Examples: IMP-Integrated Translucent Daylighting Panels |
66 | Slide 66: Review Question |
67 | Slide 67: Answer |
68 | Slide 68: IMP-Integrated Louvers |
69 | Slide 69: IMP-Integrated Louvers: Introduction |
70 | Slide 70: IMP-Integrated Louvers: Head, Sill, & Jamb Details |
71 | Slide 71: Aesthetic Feature |
72 | Slide 72: Blank-Off Panels |
73 | Slide 73: Blank-Off Panels |
74 | Slide 74: IMP-Integrated Vertical Tube Support & Accent Fins |
75 | Slide 75: IMP-Integrated Vertical Tube Support: Introduction |
76 | Slide 76: Live-Load Floor Deflection |
77 | Slide 77: Deflection Joint Solutions |
78 | Slide 78: Possible Solutions |
79 | Slide 79: Through-Tube Bypass Framing Solution |
80 | Slide 80: Installation: IMP-Integrated Vertical Tube Support System |
81 | Slide 81: Installation: IMP-Integrated Vertical Tube Support System |
82 | Slide 82: Installation: IMP-Integrated Vertical Tube Support System |
83 | Slide 83: Installation: IMP-Integrated Vertical Tube Support System |
84 | Slide 84: IMP-Integrated Accent Fins |
85 | Slide 85: Review Question |
86 | Slide 86: Answer |
87 | Slide 87: Case Studies |
88 | Slide 88: Saint Joseph’s/Candler Hospital, Savannah, GA |
89 | Slide 89: Saint Joseph’s/Candler Hospital, Savannah, GA |
90 | Slide 90: Saint Joseph’s/Candler Hospital, Savannah, GA |
91 | Slide 91: Saint Joseph’s/Candler Hospital, Savannah, GA |
92 | Slide 92: Saint Joseph’s/Candler Hospital, Savannah, GA |
93 | Slide 93: NYPA Niagara Warehouse & Office Complex, Lewiston, NY |
94 | Slide 94: NYPA Niagara Warehouse & Office Complex, Lewiston, NY |
95 | Slide 95: NYPA Niagara Warehouse & Office Complex, Lewiston, NY |
96 | Slide 96: Butler County Government Center, Butler, PA |
97 | Slide 97: Butler County Government Center, Butler, PA |
98 | Slide 98: Butler County Government Center, Butler, PA |
99 | Slide 99: Summary |
100 | Slide 100: Important Points |
101 | Slide 101: Thank You |