BS IEC 62615:2010:2011 Edition

$142.49

Electrostatic discharge sensitivity testing. Transmission line pulse (TLP). Component level

Published By Publication Date Number of Pages
BSI 2011 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 62615:2010 defines a method for pulse testing to evaluate the voltage current response of the component under test and to consider protection design parameters for electro-static discharge (ESD) human body model (HBM). This technique is known as transmission line pulse (TLP) testing. This document establishes a methodology for both testing and reporting information associated with transmission line pulse (TLP) testing. The scope and focus of this document pertains to TLP testing techniques of semiconductor components. This document should not become alternative method of HBM test standard such as IEC 60749-26. The purpose of the document is to establish guidelines of TLP methods that allow the extraction of HBM ESD parameters on semiconductor devices. This document provides the standard measurement and procedure for the correct extraction of HBM ESD parameters by using TLP.

PDF Catalog

PDF Pages PDF Title
4 English
FOREWORD
6 INTRODUCTION
7 1 Scope and object
2 Normative references
3 Terms and definitions
8 4 Test apparatus
4.1 General
9 4.2 Oscilloscope
4.3 Voltage probe
4.4 Current probe
4.5 Transmission line
4.6 High voltage power supply
4.7 High voltage switch
4.8 Attenuator
4.9 Rise time filter
10 5 TLP waveform parameters
5.1 Pulse characteristics
5.2 Pulse plateau
5.3 Pulse width
Table 1 – TLP current and voltage pulse parameters
11 5.4 Rise time
5.5 Fall time
5.6 Maximum peak current overshoot
Figures
Figure 1 – TLP waveform parameter illustration for pulse width rise time and fall time (parameters apply to both voltage and current TLP waveforms)
Figure 2 – Illustration of maximum peak current overshoot
12 5.7 Maximum current ringing duration
5.8 Maximum peak voltage overshoot
5.9 Maximum voltage ringing duration
5.10 Measurement window
6 Test requirements and procedures
6.1 Error correction
6.2 Tester error correction methodology
Figure 3 – Illustration of maximum peak voltage overshoot
13 6.3 Tester verification methodology
14 6.4 TLP test procedure
15 Figure 4 – Flow diagram for the TLP component test procedure
Figure 5 – Illustration of TLP pulse sequence
16 7 Failure criteria
7.1 General information on failure criteria
7.2 Leakage current measurement
7.3 Leakage test voltage
7.4 Documentation
17 Annex A (informative) TLP design guidelines
18 Figure A.1 – Current source TLP method
Table A.1 – TLP methodologies and parameters
19 Figure A.2 – Time domain reflectometer (TDR) TLP
Figure A.3 – Time domain reflectometer (TDR) TLP (with balun and wafer probe)
20 Figure A.4 – Time domain transmission (TDT) TLP
Figure A.5 – Time domain reflection and transmission
BS IEC 62615:2010